Negative pressure pinched sample injection for microchip-based electrophoresis

被引:43
|
作者
Zhang, L [1 ]
Yin, XF [1 ]
Fang, ZL [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310027, Peoples R China
关键词
D O I
10.1039/b511924c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple method for injecting well-defined non-biased sample plugs into the separation channel of a microfluidic chip-based capillary electrophoresis system was developed by a combination of flows generated by negative pressure, electrokinetic and hydrostatic forces. This was achieved by using only a single syringe pump and a single voltage supply at constant voltage. In the loading step, a partial vacuum in the headspace of a sealed sample waste reservoir was produced using a syringe pump equipped with a 3-way valve. Almost instantaneously, sample was drawn from the sample reservoir across the injection intersection to the sample waste reservoir by negative pressure. Simultaneously, buffer flow from the remaining two buffer reservoirs pinched the sample flow to form a well-defined sample plug at the channel intersection. In the subsequent separation stage, the vacuum in headspace of the sample waste reservoir was released to terminate all flows generated by negative pressure, and the sample plug at the channel intersection was electrokinetically injected into the separation channel under the potential applied along the separation channel. The liquid levels of the four reservoirs were optimized to prevent sample leakage during the separation stage. The approach considerably simplified the operations and equipment for pinched injection in chip-based CE, and improved the throughput. Migration time precisions of 3.3 and 1.5% RSD for rhodamine123 (Rh123) and fluorescein sodium (Flu) in the separation of a mixture of Flu and Rh 123 were obtained for 56 consecutive determinations with peak height precisions of 6.2% and 4.4% RSD for Rh123 and Flu, respectively.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [1] Acupuncture injection for field amplified sample stacking and glass microchip-based capillary gel electrophoresis
    Ha, Ji Won
    Hahn, Jong Hoon
    ELECTROPHORESIS, 2017, 38 (3-4) : 521 - 524
  • [2] Sample preconcentration by field amplification stacking for microchip-based capillary electrophoresis
    Lichtenberg, J
    Verpoorte, E
    de Rooij, NF
    ELECTROPHORESIS, 2001, 22 (02) : 258 - 271
  • [3] Micropumps actuated negative pressure injection for microchip electrophoresis
    Li, Bowei
    Jiang, Lei
    Wang, Qi
    Oin, Jianhua
    Lin, Bingcheng
    ELECTROPHORESIS, 2008, 29 (24) : 4906 - 4913
  • [4] Further improvement of hydrostatic pressure sample injection for microchip electrophoresis
    Luo, Yong
    Zhang, Qingquan
    Qin, Jianhua
    Lin, Bingcheng
    ELECTROPHORESIS, 2007, 28 (24) : 4769 - 4771
  • [5] Microchip-based capillary electrophoresis of human serum proteins
    Colyer, CL
    Mangru, SD
    Harrison, DJ
    JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) : 271 - 276
  • [6] Enantiomer separation of amino acids on microchip-based electrophoresis
    Wang, H
    Dai, ZP
    Wang, L
    Bai, JL
    Lin, BC
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (06) : 665 - 669
  • [7] Microchip-based capillary electrophoresis for determination of lactate dehydrogenase isoenzymes
    Zhuang, Gui-Sheng
    Liu, Jing
    Jia, Chun-Ping
    Jin, Qing-Hui
    Zhao, Jian-Long
    Wang, Hui-Min
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (09) : 1350 - 1356
  • [8] Improved resolution with microchip-based enhanced field inversion electrophoresis
    Backhouse, CJ
    Gajdal, A
    Pilarski, LM
    Crabtree, HJ
    ELECTROPHORESIS, 2003, 24 (11) : 1777 - 1786
  • [9] Fluorogenic assay for β-glucuronidase using microchip-based capillary electrophoresis
    Starkey, DE
    Han, A
    Bao, JJ
    Ahn, CH
    Wehmeyer, KR
    Prenger, MC
    Halsall, HB
    Heineman, WR
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 762 (01): : 33 - 41
  • [10] Microchip-based immunoassay
    Tachi, Tomoya
    Kaji, Noritada
    Tokeshi, Manabu
    Baba, Yoshinobu
    BUNSEKI KAGAKU, 2007, 56 (07) : 521 - 534