Advances in Analysis of Microcalorimeter Gamma-Ray Spectra

被引:4
|
作者
Becker, Daniel T. [1 ]
Alpert, Bradley K. [2 ]
Bennett, Douglas A. [2 ]
Croce, Mark P. [3 ]
Fowler, Joseph W. [1 ]
Gard, Johnathon D. [1 ]
Hoover, Andrew S. [3 ]
Joe, Young Il [1 ]
Koehler, Katrina E. [3 ]
Mates, John A. B. [1 ]
O'Neil, Galen C. [2 ]
Rabin, Michael W. [3 ]
Reintsema, Carl D. [2 ]
Schmidt, Daniel R. [2 ]
Swetz, Daniel S. [2 ]
Szypryt, Paul [2 ]
Vale, Leila R. [2 ]
Wessels, Abigail L. [1 ]
Ullom, Joel N. [2 ,4 ]
机构
[1] Univ Colorado, Dept Phys, Boulder, CO 80309 USA
[2] NIST, Boulder, CO 80301 USA
[3] LANL, Los Alamos, NM 87545 USA
[4] Univ Colorado, Dept Phys, Boulder, CO 80309 USA
关键词
Data analysis; detectors; gamma rays; nuclear monitoring; spectroscopy; X-RAY;
D O I
10.1109/TNS.2019.2953650
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Microcalorimeters based on transition-edge sensors (TESs) have been successfully deployed in numerous spectroscopic instruments that operate over a large range of incident photon energies. TES microcalorimeter arrays combine unmatched energy resolution with broadband spectral coverage and high quantum efficiency. An important application requiring these characteristics is nondestructive isotopic analysis via gamma-ray spectroscopy of the complex mixtures of actinide isotopes found in the nuclear fuel cycle. Steady progress has been made over the last ten years to develop TES microcalorimeter instruments for this application, leading to arrays that demonstrate significantly better energy resolution than the state-of-the-art high-purity germanium (HPGe) sensors. However, further algorithm development and automation of the data analysis procedure have been required to bring these systems closer to being ready for production use. In this article, we describe recent advances in data analysis techniques for gamma-ray data acquired with microcalorimeter systems. In particular, we discuss new approaches to automated calibration of our spectra, and a new approach for quantifying the uncertainty of peak area estimation for isolated peaks. Our data analysis pipeline has also been automated, requiring minimal manual intervention for full processing of data sets, with performance that is sufficient to allow future deployment of real-time spectrum generation. We show that, using this pipeline, we are able to achieve 0.25 statistical uncertainty in isotope ratios, which indicates that if systematic errors are controlled, microcalorimeter arrays can achieve better than 1 total uncertainty in these measurements.
引用
收藏
页码:2355 / 2363
页数:9
相关论文
共 50 条
  • [31] IMPROVED COMPUTERIZED ACQUISITION AND ANALYSIS OF GAMMA-RAY SPECTRA
    CHAPMAN, TC
    GROSS, JM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 150 - 153
  • [32] AUTOMATIC ANALYSIS OF GAMMA-RAY SPECTRA ON SMALL COMPUTERS
    ACHTERBERG, E
    SUAREZ, JF
    ROSSI, JJ
    SCHEUER, W
    MORAGUES, JA
    PEREZ, M
    JECH, AE
    IGLESIAS, FC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, 19 (05) : 3 - +
  • [33] ACCURATE EVALUATION OF GAMMA-RAY SPECTRA FOR THE MEASUREMENT OF GAMMA-RAY EMISSION PROBABILITIES
    JEDLOVSZKY, R
    POLACSEK, A
    ANDAI, A
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (08): : 1057 - 1065
  • [34] GAMMA-RAY STRENGTH FUNCTIONS FROM NEUTRON CAPTURE GAMMA-RAY SPECTRA
    GARDNER, DG
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1975, 21 (JUN): : 70 - 71
  • [35] ADVANCES IN CDTE GAMMA-RAY DETECTORS
    SERREZE, HB
    ENTINE, G
    BELL, RO
    WALD, FV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 404 - 407
  • [36] ADVANCES IN GAMMA-RAY BURST ASTRONOMY
    CLINE, TL
    DESAI, UD
    ASTROPHYSICS AND SPACE SCIENCE, 1976, 42 (01) : 17 - 27
  • [37] Integrated SQUID/Sensor Metallic Magnetic Microcalorimeter for Gamma-Ray Spectroscopy
    Boyd, S. T. P.
    Hummatov, R.
    Kim, G. B.
    Le, L. N.
    Hall, J. A.
    Cantor, R.
    Friedrich, S.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2018, 193 (3-4) : 435 - 440
  • [38] Application of Hard X-Ray and Gamma-Ray TES Microcalorimeter at Accelerator Facility
    Saito, Takeshi Y.
    Okada, Shinji
    Toyama, Yuichi
    Azuma, Toshiyuki
    Goncalo, Baptista
    Becker, Daniel T.
    Bennett, Douglas
    Doriese, William B.
    Fowler, Joseph
    Gard, Johnathon D.
    Hashimoto, Tadashi
    Hayakawa, Ryota
    Hayashi, Tasuku
    Ichinohe, Yuto
    Imrek, Jozsef
    Indelicato, Paul
    Isobe, Tadaaki
    Kanda, Sohtaro
    Kawamura, Naritoshi
    Mates, John A.
    Miyake, Yasuhiro
    Morgan, Kelsey M.
    Noda, Hirofumi
    O'Neil, Galen C.
    Okumura, Takuma
    Paul, Nancy
    Schmidt, Dan
    Shimomura, Kouichiro
    Strasser, Patrick
    Swetz, Daniel S.
    Takahashi, Tadayuki
    Tampo, Motonobu
    Ullom, Joel
    Umegaki, Izumi
    Weber, Joel C.
    Yamada, Shinya
    Yan, Daikang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2025, 35 (05)
  • [39] Transition Edge Sensor Microcalorimeter With Bismuth Absorber for Gamma-Ray Measurement
    Tsuruta, Tetsuya
    Iyomoto, Naoko
    Asagawa, Shinya
    Hamamura, Yukino
    Nishida, Yoshiki
    Maehata, Keisuke
    Mitsuda, Kazuhisa
    Hayashi, Tasuku
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (05)
  • [40] RECURSIVE FILTERING OF GAMMA-RAY SPECTRA
    GERASIMOV, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 72 (3-4): : 467 - 470