Observer variability in volumetric blood flow measurements in leg arteries using duplex ultrasound

被引:40
|
作者
Hussain, ST [1 ]
Smith, RE [1 ]
Wood, RFM [1 ]
Bland, M [1 ]
机构
[1] UNIV LONDON ST GEORGES HOSP,SCH MED,DEPT PUBL HLTH MED,TOOTING,ENGLAND
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1996年 / 22卷 / 03期
关键词
blood flow; observer variability; duplex ultrasound;
D O I
10.1016/0301-5629(95)02050-0
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Duplex ultrasound volumetric flow measurements have not found a major clinical use because of variability caused by errors in estimating cross-sectional area (CSA) and in measuring time averaged mean velocity (TAMeV). We determined inter- and intraobserver variation in volumetric blood flow measured at rest in the common femoral artery (CFA) and its main branches, the superficial femoral (SFA) and profunda femoris (PFA) arteries, in 20 normal subjects. The product of TAMeV and CSA was taken as volumetric flow. The coefficient of variation of TAMeV was consistently greater than that of CSA. Interobserver variation for blood flow (16.2%, 20.2% and 40.3% for CFA, SFA and PFA, respectively) was larger than intraobserver variation (13.0%, 15.1%, 21.2%). In conclusion, these data define the minimum changes in VQ that can be realistically detected and indicate that, with modern duplex Doppler equipment, volumetric flow can be used as a reliable haemodynamic measure for monitoring patients before and after surgical or radiological intervention.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 50 条
  • [41] ASSESSMENT OF FETOPLACENTAL AND UTEROPLACENTAL BLOOD-FLOW USING DUPLEX PULSED DOPPLER ULTRASOUND IN COMPLICATED PREGNANCIES
    CAMPBELL, S
    HERNANDEZ, CJ
    COHENOVERBECK, TA
    PEARCE, JMF
    JOURNAL OF PERINATAL MEDICINE, 1984, 12 (05) : 262 - 265
  • [42] An adaptive observer for a Stewart platform manipulator using leg position and force measurements
    Maged, Shady A.
    El Bab, Ahmed M. R. Fath
    Abouelsoud, A. A.
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2015, 24 (01) : 62 - 74
  • [43] BLOOD-FLOW MEASUREMENTS BY ULTRASOUND CORRELATION TECHNIQUES
    DOTTI, D
    GATTI, E
    SVELTO, V
    UGGE, A
    VIDALI, P
    ENERGIA NUCLEARE, 1976, 23 (11): : 571 - 575
  • [44] The blood pressure variability and blood flow velocity in the vertebral and internal carotid arteries in hypertensives
    Denisova, GA
    Balahonova, TV
    Oschepkova, EV
    Rogoza, AN
    Atkov, OY
    JOURNAL OF HYPERTENSION, 2002, 20 : S354 - S354
  • [45] Intra-rater reliability of leg blood flow during dynamic exercise using Doppler ultrasound
    Amin, Sachin B.
    Mugele, Hendrik
    Dobler, Florian E.
    Marume, Kyohei
    Moore, Jonathan P.
    Lawley, Justin S.
    PHYSIOLOGICAL REPORTS, 2021, 9 (19):
  • [46] Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements
    Goodman, LR
    Gulsun, M
    Washington, L
    Nagy, PG
    Piacsek, KL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (04) : 989 - 994
  • [47] Ultrasound blood flow imaging in carotid arteries before and after endarterectomy
    Bambi, G
    Guidi, F
    Ricci, S
    Tortoli, P
    Cirelli, MR
    Pedrini, L
    ACOUSTICAL IMAGING, VOL 27, 2004, 27 : 471 - 477
  • [48] New noninvasive Doppler ultrasound study of blood flow in the segmental arteries
    Afonin, D.N.
    Afonin, P.N.
    Meditsinskaya Tekhnika, 2002, (03): : 7 - 10
  • [49] Non-Invasive Blood Flow Measurements Using Ultrasound Modulated Diffused Light
    Racheli, N.
    Ron, A.
    Metzger, Y.
    Breskin, I.
    Enden, G.
    Balberg, M.
    Shechter, R.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223
  • [50] The Development of SIM to Characterize Blood Volumetric Flow Rate and Hemodynamics in Human Coronary Arteries
    Fayssal, I.
    Moukalled, F.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 1704 - 1707