A new hybrid FBG with a π-shift for temperature sensing in overhead high voltage transmission lines

被引:4
|
作者
El-Gammal, Hanan M. [1 ]
El-Badawy, El-Sayed A. [1 ]
Rizk, Mohamed R. M. [1 ]
Aly, Moustafa H. [2 ]
机构
[1] Alexandria Univ, Dept Elect Engn, Fac Engn, Alexandria, Egypt
[2] Arab Acad Sci Technol & Maritime Transport, Elect & Commun Engn Dept, Coll Engn & Technol, POB 1029, Alexandria, Egypt
关键词
Overhead high voltage transmission lines (OHV TL); Temperature sensors; Fiber Bragg grating (FBG); Uniform; Apodization; Pi-phase shifted FBG (pi FBG); Hybrid FBG; OptiSystem; OptiGrating; FIBER BRAGG GRATINGS; FUNDAMENTALS; SENSORS; DESIGN;
D O I
10.1007/s11082-019-2171-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Temperature monitoring in overhead high voltage transmission lines (OHV TLs) on continuous basis have become a subject of much interest and research in recent years. Since the transmission lines are subjected to various harsh meteorological and geographical conditions such as high temperature, this can cause disastrous effects on the lines such as flashovers, line breakings, and even tower collapsing. For this aim, a distributed on-line temperature monitoring system based on a new hybrid fiber Bragg grating (FBG) technology is proposed in this paper, since the development of the FBG sensing technology became prominent for the monitoring of temperature on the power lines for having several unique advantages compared to the traditional electronic sensors. The new proposed hybrid FBG consists of two apodized fiber Bragg gratings: one Nuttall and one Cos(8) separated by a pi-phase shift. This showed an optimum remarkable performance in terms of the evaluation parameters including the peak reflectivity, full width at half maximum, side lobes analysis and ripple factor as well. Moreover, it has shown a stable operation over the increased temperature when subjected to temperature variation, under the variation of the controlling parameters such as the grating length and the refractive index modulation amplitude. The proposed hybrid is compared to the traditional uniform FBGs in terms of the evaluation parameters showing its superiority as a best temperature sensor in OHV TLs.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Optimal control of the voltage and reactive power in ultra-high voltage overhead power transmission lines
    Balametov, AB
    ELECTRICAL TECHNOLOGY RUSSIA, 1998, (03): : 81 - 94
  • [32] PIPELINE VOLTAGE HAZARDS DUE TO PROXIMITY TO OVERHEAD HIGH-VOLTAGE AC TRANSMISSION-LINES
    CHERNEY, EA
    CARRIGAN, DJ
    MATERIALS PERFORMANCE, 1974, 13 (07) : 10 - 12
  • [33] On-board siren warning against approaching the overhead high voltage transmission lines
    Tusnio, Norbert
    Tusnio, Janusz
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (10): : 45 - 48
  • [34] An optimal design method for improving the lightning performance of overhead high voltage transmission lines
    Ekonomou, L
    Iracleous, DP
    Gonos, IF
    Stathopulos, IA
    ELECTRIC POWER SYSTEMS RESEARCH, 2006, 76 (6-7) : 493 - 499
  • [35] The influence of sag in the electric field calculation around high voltage overhead transmission lines
    Amiri, R.
    Hadi, H.
    Marich, M.
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 206 - 209
  • [36] Outages Calculations for Overhead High Voltage Transmission Lines using Artificial Neural Networks
    Ekonomou, L.
    Oikonomou, D. S.
    Maris, T. I.
    NEUREL 2008: NINTH SYMPOSIUM ON NEURAL NETWORK APPLICATIONS IN ELECTRICAL ENGINEERING, PROCEEDINGS, 2008, : 55 - +
  • [37] Electric Field of High Voltage Direct Current Overhead Transmission Lines with Covered Conductors
    Jiang, Yuze
    Li, Lefeng
    Jiang, Diwen
    Liang, Zhenguang
    Li, Fangwei
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 110 - 113
  • [38] A new method for calculation of corona inception voltage in stranded conductors of overhead transmission lines
    Zangeneh, Ali
    Gholami, Ahmad
    Zamani, Vahraz
    FIRST INTERNATIONAL POWER & ENERGY CONFERENCE (PECON 2006), PROCEEDINGS, 2006, : 571 - 574
  • [39] 4. OVERHEAD LINES AND SUBSTATIONS - ULTRAHIGH VOLTAGE TRANSMISSION
    ANDERSON, JG
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1973, 275 (1248): : 139 - +
  • [40] Development of FBG Tension and Tilt Sensors Applied to Ice Monitoring of Overhead Transmission Lines
    Wu, Dengjin
    PROCEEDINGS OF THE 2015 4TH NATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND COMPUTER ENGINEERING ( NCEECE 2015), 2016, 47 : 93 - 96