A new hybrid FBG with a π-shift for temperature sensing in overhead high voltage transmission lines

被引:4
|
作者
El-Gammal, Hanan M. [1 ]
El-Badawy, El-Sayed A. [1 ]
Rizk, Mohamed R. M. [1 ]
Aly, Moustafa H. [2 ]
机构
[1] Alexandria Univ, Dept Elect Engn, Fac Engn, Alexandria, Egypt
[2] Arab Acad Sci Technol & Maritime Transport, Elect & Commun Engn Dept, Coll Engn & Technol, POB 1029, Alexandria, Egypt
关键词
Overhead high voltage transmission lines (OHV TL); Temperature sensors; Fiber Bragg grating (FBG); Uniform; Apodization; Pi-phase shifted FBG (pi FBG); Hybrid FBG; OptiSystem; OptiGrating; FIBER BRAGG GRATINGS; FUNDAMENTALS; SENSORS; DESIGN;
D O I
10.1007/s11082-019-2171-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Temperature monitoring in overhead high voltage transmission lines (OHV TLs) on continuous basis have become a subject of much interest and research in recent years. Since the transmission lines are subjected to various harsh meteorological and geographical conditions such as high temperature, this can cause disastrous effects on the lines such as flashovers, line breakings, and even tower collapsing. For this aim, a distributed on-line temperature monitoring system based on a new hybrid fiber Bragg grating (FBG) technology is proposed in this paper, since the development of the FBG sensing technology became prominent for the monitoring of temperature on the power lines for having several unique advantages compared to the traditional electronic sensors. The new proposed hybrid FBG consists of two apodized fiber Bragg gratings: one Nuttall and one Cos(8) separated by a pi-phase shift. This showed an optimum remarkable performance in terms of the evaluation parameters including the peak reflectivity, full width at half maximum, side lobes analysis and ripple factor as well. Moreover, it has shown a stable operation over the increased temperature when subjected to temperature variation, under the variation of the controlling parameters such as the grating length and the refractive index modulation amplitude. The proposed hybrid is compared to the traditional uniform FBGs in terms of the evaluation parameters showing its superiority as a best temperature sensor in OHV TLs.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] A new hybrid FBG with a π-shift for temperature sensing in overhead high voltage transmission lines
    Hanan M. El-Gammal
    El-Sayed A. El-Badawy
    Mohamed R. M. Rizk
    Moustafa H. Aly
    Optical and Quantum Electronics, 2020, 52
  • [2] High Sensitive FBG Load Cell for Icing of Overhead Transmission Lines
    Mao, Naiqiang
    Ma, Guoming
    Li, Chengrong
    Li, Yabo
    Shi, Cheng
    Du, Yue
    2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS), 2017, 10323
  • [3] ULTRA-HIGH VOLTAGE OVERHEAD TRANSMISSION LINES
    ALEKSANDROV, GN
    ELECTRICAL TECHNOLOGY RUSSIA, 1971, 1 : 1 - +
  • [4] DANGER OVERHEAD + HIGH-VOLTAGE TRANSMISSION-LINES
    DIAMOND, S
    OMNI, 1978, 1 (03) : 37 - 37
  • [5] IMPACTS OF OVERHEAD HIGH-VOLTAGE TRANSMISSION-LINES
    COLEMAN, DM
    JOURNAL OF ENVIRONMENTAL SYSTEMS, 1981, 10 (04): : 283 - 304
  • [6] Wind and environmental effects on overhead high voltage transmission lines
    Abdel-Gawad, A. F.
    Zoklot, A. -S. A.
    SUSTAINABLE CITY IV : URBAN REGENERATION AND SUSTAINABILITY, 2006, 93 : 433 - +
  • [7] An alternative procedure for the design of high voltage overhead transmission lines
    Saied, MM
    1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 708 - 714
  • [8] Ice Monitoring on Overhead Transmission Lines with FBG Tension Sensor
    Ma Guo-ming
    Li Cheng-rong
    Meng Chen-ping
    Quan Jiang-tao
    Cheng Yang-Chun
    Jiang Jian
    Tian Xiao
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [9] Hybrid Optoelectronic Sensor for Current and Temperature Monitoring in Overhead Transmission Lines
    Batista de Nazare, Fabio Vieira
    Werneck, Marcelo Martins
    IEEE SENSORS JOURNAL, 2012, 12 (05) : 1193 - 1194
  • [10] MAINTENANCE STRATEGY FOR HIGH-VOLTAGE OVERHEAD TRANSMISSION-LINES
    SPIESS, K