A novel method for measuring absolute coronary blood flow and microvascular resistance in patients with ischaemic heart disease

被引:34
|
作者
Morris, Paul D. [1 ,2 ,3 ]
Gosling, Rebecca [1 ,2 ,3 ]
Zwierzak, Iwona [1 ,3 ]
Evans, Holli [1 ]
Aubiniere-Robb, Louise [1 ]
Czechowicz, Krzysztof [1 ]
Evans, Paul C. [1 ,3 ,4 ]
Hose, D. Rodney [1 ,3 ,5 ]
Lawford, Patricia, V [1 ,3 ]
Narracott, Andrew J. [1 ,3 ]
Gunn, Julian P. [1 ,2 ,3 ]
机构
[1] Univ Sheffield, Med Sch, Dept Infect Immun & Cardiovasc Dis, Math Modelling Med Grp, Sheffield, S Yorkshire, England
[2] Sheffield Teaching Hosp NHS Fdn Trust, Dept Cardiol, Sheffield, S Yorkshire, England
[3] Univ Sheffield, Insigneo Inst Silico Med, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Bateson Ctr, Sheffield, S Yorkshire, England
[5] Norwegian Univ Sci & Technol NTNU, Dept Circulat & Med Imaging, Trondheim, Norway
基金
英国惠康基金; 英国医学研究理事会;
关键词
Coronary blood flow; Computational fluid dynamics; Coronary physiology; Coronary angiography; Coronary microvascular dysfunction; SUBSELECTIVE MEASUREMENT; CARDIAC-CATHETERIZATION; DIAGNOSTIC-ACCURACY; MEDICAL THERAPY; ARTERY-DISEASE; RESERVE; VELOCITY; PRESSURE; DYSFUNCTION; RISK;
D O I
10.1093/cvr/cvaa220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Ischaemic heart disease is the reduction of myocardial blood flow, caused by epicardial and/or microvascular disease. Both are common and prognostically important conditions, with distinct guideline-indicated management. Fractional flow reserve (FFR) is the current gold-standard assessment of epicardial coronary disease but is only a surrogate of flow and only predicts percentage flow changes. It cannot assess absolute (volumetric) flow or microvascular disease. The aim of this study was to develop and validate a novel method that predicts absolute coronary blood flow and microvascular resistance (MVR) in the catheter laboratory. Methods and results A computational fluid dynamics (CFD) model was used to predict absolute coronary flow (Q(CFD)) and coronary MVR using data from routine invasive angiography and pressure-wire assessment. Q(CFD) was validated in an in vitro flow circuit which incorporated patient-specific, three-dimensional printed coronary arteries; and then in vivo, in patients with coronary disease. In vitro, QCFD agreed closely with the experimental flow over all flow rates [bias +2.08 mL/min; 95% confidence interval (error range) -4.7 to +8.8 mL/min; R-2 = 0.999, P < 0.001; variability coefficient <1%]. In vivo, Q(CFD) and MVR were successfully computed in all 40 patients under baseline and hyperaemic conditions, from which coronary flow reserve (CFR) was also calculated. Q(CFD)-derived CFR correlated closely with pressure-derived CFR (R-2 = 0.92, P < 0.001). This novel method was significantly more accurate than Doppler-wire-derived flow both in vitro (+/- 6.7 vs. +/- 34 mL/min) and in vivo (+/- 0.9 vs. +/- 24.4 mmHg). Conclusions Absolute coronary flow and MVR can be determined alongside FFR, in absolute units, during routine catheter laboratory assessment, without the need for additional catheters, wires or drug infusions. Using this novel method, epicardial and microvascular disease can be discriminated and quantified. This comprehensive coronary physiological assessment may enable a new level of patient stratification and management. [GRAPHICS] .
引用
收藏
页码:1567 / 1577
页数:11
相关论文
共 50 条
  • [41] Development and validation of a novel angiography-derived index of absolute coronary blood flow and resistance
    Marin, Federico
    Fawaz, Samer
    Kotronias, Rafail A.
    Chai, Jason
    Chu, Miao
    Karamasis, Grigoris V.
    Cook, Christopher M.
    Khan, Sarosh
    Davies, John R.
    Channon, Keith
    Banning, Adrian P.
    Keeble, Thomas R.
    De Maria, Giovanni Luigi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (10): : 2103 - 2115
  • [42] Development and Validation of a Novel Angiography-Derived Index of Absolute Coronary Blood Flow and Resistance
    Marin, Federico
    Fawaz, Samer
    Kotronias, Rafail
    Chai, Jason
    Channon, Keith
    Karamasis, Grigoris
    Cook, Christopher
    Khan, Sarosh
    Davies, John
    Banning, Adrian
    Keeble, Thomas
    De Maria, Giovanni Luigi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B133 - B133
  • [43] Coronary microvascular dysfunction in stable ischaemic heart disease (non-obstructive coronary artery disease and obstructive coronary artery disease)
    Sechtem, Udo
    Brown, David
    Godo, Shigeo
    Lanza, Gaetano Antonio
    Shimokawa, Hiro
    Sidik, Novalia
    CARDIOVASCULAR RESEARCH, 2020, 116 (04) : 771 - 786
  • [44] EFFECT OF ELECTIVE PERCUTANEOUS CORONARY INTERVENTION ON HYPEREMIC ABSOLUTE CORONARY BLOOD FLOW VOLUME AND MICROVASCULAR RESISTANCE EVALUATED BY TRANSTHORACIC DOPPLER ECHOCARDIOGRAPHY
    Yamaguchi, Masao
    Hoshino, Masahiro
    Nogami, Kai
    Ueno, Hiroki
    Hirano, Hidenori
    Misawa, Toru
    Hada, Masahiro
    Sumino, Yohei
    Kanaji, Yoshihisa
    Sugiyama, Tomoyo
    Yonetsu, Taishi
    Kakuta, Tsunekazu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1789 - 1789
  • [45] A NEW METHOD FOR MEASURING ABSOLUTE RENAL BLOOD-FLOW
    COSGROVE, MD
    EVANS, K
    CLEGG, J
    BRITISH JOURNAL OF SURGERY, 1967, 54 (03) : 238 - &
  • [46] Rheological properties of blood in patients with ischaemic heart disease
    Palanduz, S
    Tamer, S
    Vatansever, S
    Karan, MA
    Çefle, K
    Öztürk, S
    Güler, K
    Kudat, H
    Kayserilioglu, A
    MEDICAL SCIENCE RESEARCH, 1999, 27 (05): : 327 - 329
  • [47] Coronary Microvascular Dysfunction in Patients with Congenital Heart Disease
    Vanreusel, Inne
    Segers, Vincent F. M.
    Van Craenenbroeck, Emeline
    Van Berendoncks, An
    CURRENT CARDIOLOGY REVIEWS, 2023, 19 (04) : 32 - 46
  • [48] Absolute coronary blood flow measurement and microvascular resistance in ST-elevation myocardial infarction in the acute and subacute phase
    Wijnbergen, Inge
    van't Veer, Marcel
    Lammers, Jeroen
    Ubachs, Joey
    Pijls, Nico H. J.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2016, 17 (02) : 81 - 87
  • [49] Absolute blood flow and oxygen consumption in stunned myocardium in patients with coronary artery disease
    Barnes, E
    Hall, RJC
    Dutka, DP
    Camici, PG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) : 420 - 427
  • [50] Absolute coronary flow and microvascular resistance before and after transcatheter aortic valve implantation
    Gallinoro, Emanuele
    Paolisso, Pasquale
    Bertolone, Dario Tino
    Esposito, Giuseppe
    Belmonte, Marta
    Leone, Attilio
    Viscusi, Michele Mattia
    Shumkova, Monika
    De Colle, Cristina
    Degrieck, Ivan
    Casselman, Filip
    Penicka, Martin
    Collet, Carlos
    Sonck, Jeroen
    Wyffels, Eric
    Bartunek, Jozef
    De Bruyne, Bernard
    Vanderheyden, Marc
    Barbato, Emanuele
    EUROINTERVENTION, 2024, 20 (19)