A novel method for measuring absolute coronary blood flow and microvascular resistance in patients with ischaemic heart disease

被引:34
|
作者
Morris, Paul D. [1 ,2 ,3 ]
Gosling, Rebecca [1 ,2 ,3 ]
Zwierzak, Iwona [1 ,3 ]
Evans, Holli [1 ]
Aubiniere-Robb, Louise [1 ]
Czechowicz, Krzysztof [1 ]
Evans, Paul C. [1 ,3 ,4 ]
Hose, D. Rodney [1 ,3 ,5 ]
Lawford, Patricia, V [1 ,3 ]
Narracott, Andrew J. [1 ,3 ]
Gunn, Julian P. [1 ,2 ,3 ]
机构
[1] Univ Sheffield, Med Sch, Dept Infect Immun & Cardiovasc Dis, Math Modelling Med Grp, Sheffield, S Yorkshire, England
[2] Sheffield Teaching Hosp NHS Fdn Trust, Dept Cardiol, Sheffield, S Yorkshire, England
[3] Univ Sheffield, Insigneo Inst Silico Med, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Bateson Ctr, Sheffield, S Yorkshire, England
[5] Norwegian Univ Sci & Technol NTNU, Dept Circulat & Med Imaging, Trondheim, Norway
基金
英国惠康基金; 英国医学研究理事会;
关键词
Coronary blood flow; Computational fluid dynamics; Coronary physiology; Coronary angiography; Coronary microvascular dysfunction; SUBSELECTIVE MEASUREMENT; CARDIAC-CATHETERIZATION; DIAGNOSTIC-ACCURACY; MEDICAL THERAPY; ARTERY-DISEASE; RESERVE; VELOCITY; PRESSURE; DYSFUNCTION; RISK;
D O I
10.1093/cvr/cvaa220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Ischaemic heart disease is the reduction of myocardial blood flow, caused by epicardial and/or microvascular disease. Both are common and prognostically important conditions, with distinct guideline-indicated management. Fractional flow reserve (FFR) is the current gold-standard assessment of epicardial coronary disease but is only a surrogate of flow and only predicts percentage flow changes. It cannot assess absolute (volumetric) flow or microvascular disease. The aim of this study was to develop and validate a novel method that predicts absolute coronary blood flow and microvascular resistance (MVR) in the catheter laboratory. Methods and results A computational fluid dynamics (CFD) model was used to predict absolute coronary flow (Q(CFD)) and coronary MVR using data from routine invasive angiography and pressure-wire assessment. Q(CFD) was validated in an in vitro flow circuit which incorporated patient-specific, three-dimensional printed coronary arteries; and then in vivo, in patients with coronary disease. In vitro, QCFD agreed closely with the experimental flow over all flow rates [bias +2.08 mL/min; 95% confidence interval (error range) -4.7 to +8.8 mL/min; R-2 = 0.999, P < 0.001; variability coefficient <1%]. In vivo, Q(CFD) and MVR were successfully computed in all 40 patients under baseline and hyperaemic conditions, from which coronary flow reserve (CFR) was also calculated. Q(CFD)-derived CFR correlated closely with pressure-derived CFR (R-2 = 0.92, P < 0.001). This novel method was significantly more accurate than Doppler-wire-derived flow both in vitro (+/- 6.7 vs. +/- 34 mL/min) and in vivo (+/- 0.9 vs. +/- 24.4 mmHg). Conclusions Absolute coronary flow and MVR can be determined alongside FFR, in absolute units, during routine catheter laboratory assessment, without the need for additional catheters, wires or drug infusions. Using this novel method, epicardial and microvascular disease can be discriminated and quantified. This comprehensive coronary physiological assessment may enable a new level of patient stratification and management. [GRAPHICS] .
引用
收藏
页码:1567 / 1577
页数:11
相关论文
共 50 条
  • [1] ABSOLUTE CORONARY BLOOD FLOW AND MICROVASCULAR RESISTANCE MODELLING IN PATIENTS WITH CORONARY ARTERY DISEASE
    Aubiniere-Robb, Louise
    Morris, Paul
    Gunn, Julian
    Gosling, Rebecca
    Hose, Rodney
    Rammohan, Vignesh
    Lawford, Patricia
    HEART, 2021, 107 : A29 - A30
  • [2] Measuring Absolute Coronary Flow and Microvascular Resistance by Thermodilution
    Belmonte, Marta
    Gallinoro, Emanuele
    Pijls, Nico H. J.
    Bertolone, Dario Tino
    Keulards, Danielle C. J.
    Viscusi, Michele Mattia
    Storozhenko, Tatyana
    Mizukami, Takuya
    Mahendiran, Thabo
    Seki, Ruiko
    Fournier, Stephane
    de Vos, Annemiek
    Adjedj, Julien
    Barbato, Emanuele
    Sonck, Jeroen
    Damman, Peter
    Keeble, Thomas
    Fawaz, Samer
    Gutierrez-Barrios, Alejandro
    Paradies, Valeria
    Bouisset, Frederic
    Kern, Morton J.
    Fearon, William F.
    Collet, Carlos
    De Bruyne, Bernard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (06) : 699 - 709
  • [3] Quantification of Absolute Coronary Blood Flow and Microvascular Resistance
    Harbaoui, Brahim
    Muller, Olivier
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (10)
  • [4] The Complementary Value of Absolute Coronary Flow in the Assessment of Patients with Ischaemic Heart Disease
    Aubiniere-Robb, Louise
    Gosling, Rebecca
    Taylor, Daniel J.
    Newman, Tom
    Hose, D. Rodney
    Halliday, Ian
    Lawford, Patricia V.
    Narracott, Andrew J.
    Gunn, Julian P.
    Morris, Paul D.
    NATURE CARDIOVASCULAR RESEARCH, 2022, 1 (07): : 611 - +
  • [5] The Complementary Value of Absolute Coronary Flow in the Assessment of Patients with Ischaemic Heart Disease
    Louise Aubiniere-Robb
    Rebecca Gosling
    Daniel J. Taylor
    Tom Newman
    D. Rodney Hose
    Ian Halliday
    Patricia V. Lawford
    Andrew J. Narracott
    Julian P. Gunn
    Paul D. Morris
    Nature Cardiovascular Research, 2022, 1 : 611 - 616
  • [6] Impact of coronary sinus reducer on absolute coronary blood flow and microvascular resistance
    Servoz, Clement
    Verheye, Stefan
    Giannini, Francesco
    Banai, Shmuel
    Fradi, Mohamed
    Cuenin, Leo
    Bellemain-Appaix, Anne
    Gilard, Martine
    Benamer, Hakim
    Adjedj, Julien
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 104 (01) : 58 - 60
  • [7] Microvascular Resistance and Absolute Coronary Blood Flow Quantification in Takotsubo Cardiomyopathy
    Gutierrez-Barrios, Alejandro
    Rivero, Fernando
    Gheorghe, Livia L.
    Calle Perez, German
    De Zayas Rueda, Ricardo
    Alfonso, Fernando
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B468 - B468
  • [8] Measurement of Absolute Coronary Blood Flow and Microvascular Resistance A New Window to Coronary Microcirculation
    Pijls, Nico H. J.
    de Vos, Annemiek M. J.
    Keulards, Danielle C. J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (06) : 742 - 744
  • [9] Myocardial blood flow reserve and absolute myocardial blood flow for the assessment of patients with coronary artery disease with or without microvascular dysfunction
    Giubbini, Raffaele
    Cerudelli, Elisabetta
    Camoni, Luca
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) : 3007 - 3009
  • [10] Myocardial blood flow reserve and absolute myocardial blood flow for the assessment of patients with coronary artery disease with or without microvascular dysfunction
    Raffaele Giubbini
    Elisabetta Cerudelli
    Luca Camoni
    Journal of Nuclear Cardiology, 2021, 28 : 3007 - 3009