Dynamic operational characteristics and preliminary control of a packed liquid desiccant dehumidifier

被引:5
|
作者
Zhang, Xiaobo [2 ]
Zhu, Yuxian [2 ]
Xu, Xiangguo [1 ,2 ]
Ji, Xiaosheng [3 ]
机构
[1] Zhejiang Univ, Ctr Balance Architecture, 38 Zheda Rd, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Key Lab Refrigerat & Cryogen Technol Zhejiang Pro, Inst Refrigerat & Cryogen, 38 Zheda Rd, Hangzhou 310027, Peoples R China
[3] Chinese Acad Sci, Sanya Inst Oceanol, Sanya 572000, Hainan, Peoples R China
关键词
Dynamic characteristics; Control performance; Liquid desiccant; Packed dehumidifier; MASS-TRANSFER; AIR; HEAT;
D O I
10.1016/j.enbuild.2021.111185
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Liquid desiccant dehumidifiers (LDDs) has attracted much attention due to its advantages of energy saving and environmental protection. However, dynamic characteristics of LDDs, which are essential to develop appropriate control methods, are still not clear at present. In this paper, the performance of a packed LDD was investigated under changes of desiccant inlet temperature and flow rate as well as air inlet humidity ratio, temperature and flow rate. Due to the random packings and interaction between air and desiccant, the air is normally distributed randomly during a dynamic process of LDDs and air outlet humidity ratio at the sampling point is serrated with time going. It was found that exponent function could be utilized to smooth the experimental result of air outlet humidity ratio, providing a simple way to determine the evaluation indexes like the response delay and response time as well as response rate, which could facilitate to evaluate dynamic characteristics of the dehumidifier. And through comparing those evaluation indexes corresponding to changes of different inlet parameters, it was revealed that air outlet humidity ratio was more sensitive to the change of desiccant or air flow rate, but not desiccant inlet temperature as indicated in a previous research getting from quasi-steady state experiments. Therefore, it would be more reasonable to select the desiccant or air flow rate as control variables instead of desiccant inlet temperature. Furthermore, preliminary control experiments were conducted to compare the performance of control algorithms developed based on the steady state characteristics and expert experience of dynamic characteristics. Results show that the control algorithm developed based on the expert experience of dynamic characteristics performs much better, which indicates that the obtained steady state characteristics in existing researches are unsuitable for developing control algorithms for a packed LDD. The dynamic characteristics revealed in current research paves the way for the future development of appropriate control algorithms. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant
    Liu, X. H.
    Jiang, Y.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) : 1357 - 1366
  • [22] A dynamic model of the packed dehumidifier
    Zhang, Xiaobo
    Xu, Xiangguo
    Lee, Duu-Jong
    JOURNAL OF CLEANER PRODUCTION, 2023, 429
  • [23] Dynamic and microscopic simulation of the counter-current flow in a liquid desiccant dehumidifier
    Luo, Yimo
    Yang, Hongxing
    Lu, Lin
    APPLIED ENERGY, 2014, 136 : 1018 - 1025
  • [24] GAS-POWERED LIQUID DESICCANT DEHUMIDIFIER
    RIX, J
    NEVRALA, D
    CHAUVET, L
    PROBERT, SD
    APPLIED ENERGY, 1993, 45 (02) : 167 - 180
  • [25] Analysis on the Significance of Effects from Operational Conditions on the Performances of Ultrasonic Atomization Dehumidifier with Liquid Desiccant
    Yang, Zili
    Zhang, Kaisheng
    Lian, Zhiwei
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 89 - 94
  • [26] Experimental investigation on structured packed bed liquid desiccant dehumidifier: An optimal mixture design of experiments strategy
    Bhowmik, Mrinal
    Muthukumar, P.
    Anandalakshmi, R.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 122 : 232 - 244
  • [27] Study of a waste heat driven modified packed desiccant bed dehumidifier
    Fathalah, K
    Aly, SE
    ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (04) : 457 - 471
  • [28] Characteristics of dehumidifier sheets for an adsorptive desiccant cooling system
    Tashiro, Y
    Kubo, M
    Katsumi, Y
    Meguro, T
    Komeya, K
    Tatami, J
    CHARACTERIZATION AND CONTROL OF INTERFACES FOR HIGH QUALITY ADVANCED MATERIALS, 2005, 146 : 199 - 205
  • [29] CFD simulation of the liquid flow on structured packing in the liquid desiccant dehumidifier
    Luo, Yimo
    Yang, Hongxing
    Lu, Lin
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 180 - 183
  • [30] Improved utilization of desiccant material in packed bed dehumidifier using composite particles
    Ramzy, A. K.
    Kadoli, R.
    Babu, T. P. Ashok
    RENEWABLE ENERGY, 2011, 36 (02) : 732 - 742