Afterglow Suppression by Codoping with Bi in CsI:Tl Crystal Scintillator

被引:32
|
作者
Totsuka, Daisuke [1 ,3 ]
Yanagida, Takayuki [2 ]
Fujimoto, Yutaka [3 ]
Yokota, Yuui [3 ]
Moretti, Federico [4 ]
Vedda, Anna [4 ]
Yoshikawa, Akira [2 ,3 ]
机构
[1] Nihon Kessho Kogaku Co Ltd, Gunma, Japan
[2] New Ind Creat Hatchery Ctr NICHe, Sendai, Miyagi 9808579, Japan
[3] Tohoku Univ, Inst Mat Res, Sendai, Miyagi 9808577, Japan
[4] Univ Milano Bicocca, Dept Mat Sci, I-20125 Milan, Italy
基金
日本学术振兴会;
关键词
TL CRYSTALS; RADIOLUMINESCENCE;
D O I
10.1143/APEX.5.052601
中图分类号
O59 [应用物理学];
学科分类号
摘要
Single crystals of CsI, CsI:Tl, and CsI:Tl, Bi were grown by the vertical Bridgman method. We studied the effect of Bi3+ codoping on the CsI:Tl X-ray-induced afterglow. Thermally stimulated luminescence measurements were carried out in order to investigate the role of traps. The results showed a remarkable reduction of afterglow, of about an order of magnitude, and of trap concentration by Bi codoping. These improvements could be related to a possible role of Bi in the compensation of intrinsic nonstoichiometry defects. (c) 2012 The Japan Society of Applied Physics
引用
收藏
页数:3
相关论文
共 50 条
  • [41] A Study of CsI(Tl) Scintillator with Optimized Conditions of Large Area Avalanche Photodiode
    Kim, Minjeong
    Kang, Heedong
    Kim, H. J.
    Kim, Wan
    Park, H.
    Kim, Sunghwan
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 586 - 589
  • [42] Portal imaging with a CsI(Tl) transparent scintillator x-ray detector
    Zeman, HD
    Samant, SS
    Lovhoiden, G
    Weinberg, B
    Sawant, A
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 175 - 186
  • [43] Energy and position reconstruction on CsI(Tl) scintillator detector array in TEXONO experiment
    Zhu, Yue-Feng
    Li, Yu-Lan
    Wong, Henry Tsz-King
    Li, Jin
    Singh, Venktesh
    Lin, Shin-Ted
    Kao Neng Wu Li Yu Ho Wu Li/High Energy Physics and Nuclear Physics, 2005, 29 (03): : 288 - 294
  • [44] Particle identification method in the CsI(Tl) scintillator used for the CHIMERA 4π detector
    Alderighi, M
    Anzalone, A
    Basssini, R
    Berceanu, I
    Blicharska, J
    Boiano, C
    Borderie, B
    Bougault, R
    Bruno, M
    Cali, C
    Cardella, G
    Cavallaro, S
    D'Agostino, M
    D'Andrea, M
    Dayras, R
    De Filippo, E
    Fichera, F
    Geraci, E
    Giustolisi, F
    Grzeszczuk, A
    Guardone, N
    Guazzoni, P
    Guinet, D
    Iacono-Manno, CM
    Kowalski, S
    La Guidara, E
    Lanchais, AL
    Lanzalone, G
    Lanzanó, G
    Le Neindre, N
    Li, S
    Maiolino, C
    Majka, Z
    Manfredi, G
    Nicotra, D
    Paduszynski, T
    Pagano, A
    Papa, M
    Petrovici, CM
    Piasecki, E
    Pirrone, S
    Politi, G
    Pop, A
    Porto, F
    Rivet, MF
    Rosato, E
    Saccá, G
    Sechi, G
    Simion, V
    Sperduto, ML
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 489 (1-3): : 257 - 265
  • [45] Gamma ray spectroscopy with CsI(Tl) scintillator coupled to silicon drift chamber
    Fiorini, C
    Longoni, A
    Perotti, F
    Labanti, C
    Lechner, P
    Struder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) : 2553 - 2560
  • [46] Improvement of the sensitivity and spatial resolution of pixelated CsI:Tl scintillator with reflective coating
    Cha, Bo Kyung
    Bae, Jun Hyung
    Lee, Chae-hun
    Jeon, Hosang
    Kim, Hyunduk
    Chang, Sungho
    Kang, Bo-Sun
    Cho, Gyuseong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 145 - 149
  • [47] Experiments on high excitation density, quenching, and radiative kinetics in CsI:Tl scintillator
    Grim, Joel Q.
    Li, Qi
    Ucer, K. B.
    Williams, R. T.
    Moses, W. W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 284 - 287
  • [48] Tl concentration and its variation in a CsI(Tl) crystal for the CALIFA detector
    Knyazev, A.
    Park, J.
    Golubev, P.
    Pallon, J.
    Cederkall, J.
    Alvarez-Pol, H.
    Benlliure, J.
    Briz, J. A.
    Cabanelas, P.
    Casarejos, E.
    Cortina-Gil, D.
    Diaz Fernandez, P.
    Feijoo, M.
    Galaviz, D.
    Galiana, E.
    Borge, M. J. G.
    Gernhaeuser, R.
    Gonzalez, D.
    Gutierrez-Neira, C.
    Hartig, A-L
    Heinz, A.
    Heiss, B.
    Johansson, H.
    Klenze, P.
    Kroell, T.
    Nilsson, T.
    Perea, A.
    Ponnath, L.
    Rhee, H-B
    Rodriguez-Sanchez, J. L.
    Tengblad, O.
    Teubig, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 975
  • [49] Energy & position reconstruction on CsI(Tl) scintillator detector array in TEXONO experiment
    Zhu, YF
    Li, YL
    Wong, HTK
    Li, J
    Venktesh, S
    Lin, ST
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (03): : 288 - 294
  • [50] NaI(Tl) and CsI(Tl) scintillation crystal growth by skull method
    Taranyuk, V.
    Gektin, A.
    Kisil, I.
    Kolesnikov, A.