Effect of Excitation Voltage and Lead wire Resistance on Strain Measurement

被引:0
|
作者
Gaikar, Satish V. [1 ]
Deshmukh, Nilaj N. [1 ]
机构
[1] Univ Mumbai, Dept Mech Engn, Fr Conceicao Rodrigues Inst Technol, Navi Mumbai, India
关键词
labview; strain gauges; Wheatstone bridge; uncertainty Analysis;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The strain gauges are used to measure a strain in many practical applications. The uncertainty in measurement of strain is due to different factors such as excitation voltage, lead wire resistance and temperature. The aim of this project is to determine uncertainty in measurement for three bridge configurations for different parameters. The experimental sets up for three bridge configurations are developed for cantilever beam. The strain is calculated for different loads on cantilever beam from the pure bending theory using the hook's law formula and finite element analysis are validated with experimental measurements. The data has been analyzed for uncertainty in strain measurement for full bridge, half bridge and quarter bridge circuits. The result shows that full bridge configuration has minimum uncertainty value compare to other two bridges.
引用
收藏
页码:747 / 752
页数:6
相关论文
共 50 条
  • [41] APPLICATION OF VIBRATING-WIRE PRINCIPLE FOR MEASUREMENT OF STRAIN IN CONCRETE
    HORNBY, IW
    NOLTINGK, BE
    EXPERIMENTAL MECHANICS, 1974, 14 (03) : 123 - 128
  • [42] RESISTANCE APPARATUS FOR THE CONTINUOUS MEASUREMENT OF FINE WIRE UNIFORMITY
    MICHAELS, AI
    WEAVER, TL
    NELSON, RC
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1960, 218 (06): : 1070 - 1076
  • [43] AN ACCURATE WIRE RESISTANCE METHOD FOR THE MEASUREMENT OF PULSATING PRESSURES
    GROSS, N
    LANE, PHR
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1953, 30 (01): : 1 - 2
  • [44] Lead-resistance effects in a constant voltage anemometer
    Comte-Bellot, G
    Weiss, J
    Béra, JC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (06): : 2075 - 2081
  • [45] An improved lead wire compensation technique for conventional four wire resistance temperature detectors (RTDs)
    Sen, S. K.
    Pan, T. K.
    Ghosal, P.
    MEASUREMENT, 2011, 44 (05) : 842 - 846
  • [46] An improved lead wire compensation technique for conventional two wire resistance temperature detectors (RTDs)
    Sen, SK
    MEASUREMENT, 2006, 39 (05) : 477 - 480
  • [47] ELECTRICAL IMPEDANCE MEASUREMENT USING VOLTAGE/CURRENT PULSE EXCITATION
    Mejia-Aguilar, Abraham
    Pallas-Areny, Ramon
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 662 - 667
  • [48] Voltage measurement transformer with negative resistance converter
    Nawrocki, Zdzislaw
    Kosobudzki, Grzegorz
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (06): : 114 - 116
  • [49] MEASUREMENT OF VOLTAGE-STABLE NEGATIVE RESISTANCE
    TODD, CD
    SEMICONDUCTOR PRODUCTS AND SOLID STATE TECHNOLOGY, 1965, 8 (11): : 17 - &
  • [50] The effect of series resistance on threshold voltage measurement techniques for fully depleted SOI MOSFETs
    Wainwright, SP
    Hall, S
    Flandre, D
    SOLID-STATE ELECTRONICS, 1996, 39 (01) : 89 - 94