Comparison of air displacement plethysmography with dual-energy X-ray absorptiometry and 3 field methods for estimating body composition in middle-aged men

被引:111
|
作者
Sardinha, LB
Lohman, TG
Teixeira, PJ
Guedes, DP
Going, SB
机构
[1] Univ Arizona, Dept Physiol, Body Composit Res Lab, Tucson, AZ 85721 USA
[2] Univ Tecn Lisboa, Fac Human Movement, Exercise & Hlth Lab, P-1100 Lisbon, Portugal
来源
关键词
bioelectrical impedance analysis; BIA; bioelectrical impedance spectroscopy; dual-energy X-ray absorptiometry; DXA; air displacement plethysmography; percentage body fat; predictive accuracy; reliability; Portugal; men;
D O I
10.1093/ajcn/68.4.786
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
This study was designed to compare air displacement plethysmography with dual-energy X-ray absorptiometry (DXA) and 3 other field methods for estimation of body composition. Subjects were 62 healthy, white men aged 37.6 +/- 2.9 y (weight: 81.8 +/- 11.3 kg; height: 171.5 +/- 4.9 cm). Body composition was also assessed by using body mass index, single-frequency bioelectrical impedance analysis, multifrequency bioelectrical impedance spectroscopy, and the skinfold-thickness equations of Jackson and Pollock and Durnin and Womersley. Percentage body fat (%BF) with the plethysmograph was 23.4 +/- 7.0 and with DXA was 26.0 +/- 7.4. The 2.6% mean difference was significant (P < 0.05). Total error was 3.7%BF As assessed by multiple regression analysis, %BF with the plethysmograph, age, weight, and height yielded a DXA-adjusted R-2 value of 89.5% fat and an SEE of 2.4% fat. All other models had higher SEEs and lower adjusted R-2 values: 4.3% and 66.5% for body mass index, 3.3% and 79.8% for bioelectrical impedance analysis, 3.6% and 76.2% for bioelectrical impedance spectroscopy, 3.7% and 74.55% for the equations of Jackson and Pollock, and 3.9% and 71.6% for the equations of Durnin and Womersley, respectively. The plethysmograph also predicted fat mass and fat-free mass more accurately than all other models, with a lower SEE and higher adjusted R-2 value. In conclusion, although %BF was systematically underestimated, body composition was closely estimated with air displacement plethysmography in middle-aged men.
引用
收藏
页码:786 / 793
页数:8
相关论文
共 50 条
  • [21] Body Composition Assessment by Air-Displacement Plethysmography Compared to Dual-Energy X-ray Absorptiometry in Full-Term and Preterm Aged Three to Five Years
    van Beijsterveldt, Inge A. L. P.
    Beunders, Victoria A. A.
    Bijlsma, Alja
    Vermeulen, Marijn J.
    Joosten, Koen F. M.
    Hokken-Koelega, Anita C. S.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (06)
  • [22] Comparison of two phantoms for body composition with dual-energy X-ray absorptiometry
    Diessel, E
    Shepherd, JA
    Fuerst, T
    Gonzalez, M
    Genant, HK
    Carew, B
    Looker, A
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 107 - 110
  • [23] Accuracy And Reliability Of Body Composition Measurements Using Dual-energy X-ray Absorptiometey And Air Displacement Plethysmography
    Miller, Wayne C.
    Diamond, Jacyln L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S302 - S303
  • [24] Comparison of Circumference Measures with Dual-Energy X-Ray Absorptiometry Assessment of Body Composition in Young Men
    Mitchell, Katherine
    Pritchett, Robert
    Gee, David
    Pritchett, Kelly
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 269 - 269
  • [25] Body composition assessment in athletes with spinal cord injury: comparison of field methods with dual-energy X-ray absorptiometry
    Mojtahedi, M. C.
    Valentine, R. J.
    Evans, E. M.
    SPINAL CORD, 2009, 47 (09) : 698 - 704
  • [26] Body composition assessment in athletes with spinal cord injury: comparison of field methods with dual-energy X-ray absorptiometry
    M C Mojtahedi
    R J Valentine
    E M Evans
    Spinal Cord, 2009, 47 : 698 - 704
  • [27] Dual-energy x-ray absorptiometry and body composition: Differences between devices and comparison with reference methods
    Genton, L
    Hans, D
    Kyle, UG
    Pichard, C
    NUTRITION, 2002, 18 (01) : 66 - 70
  • [28] Estimating lean body mass by dual-energy x-ray absorptiometry
    Kooman, JP
    Konings, CJ
    Leunissen, KML
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 38 (01) : 220 - 221
  • [29] Validation of air displacement plethysmography with dual energy X-ray absorptiometry: Effect of clothing
    Hull, H
    Fields, D
    OBESITY RESEARCH, 2004, 12 : A118 - A118
  • [30] DETERMINATION OF BODY-COMPOSITION - A COMPARISON OF DUAL-ENERGY X-RAY ABSORPTIOMETRY AND HYDRODENSITOMETRY
    JOHANSSON, AG
    FORSLUND, A
    SJODIN, A
    MALLMIN, H
    HAMBRAEUS, L
    LJUNGHALL, S
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (03): : 323 - 326