Free Hand Pedicle Screw Placement in the Thoracic Spine without Any Radiographic Guidance: Technical Note, a Cadaveric Study

被引:26
|
作者
Hyun, Seung-Jae [2 ]
Kim, Yongjung J. [1 ]
Cheh, Gene [3 ]
Yoon, Seung Hwan [4 ]
Rhim, Seung-Chul [1 ,5 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Neurosurg, Seoul 138736, South Korea
[2] Seoul Natl Univ, Coll Med, Bundang Hosp, Dept Neurosurg,Spine Ctr, Songnam, South Korea
[3] Wooridul Spine Hosp, Dept Orthoped Surg, Seoul, South Korea
[4] Inha Univ, Dept Neurosurg, Coll Med, Inchon, South Korea
[5] Columbia Univ Coll Phys & Surg, Dept Orthopaed Surg, Spine Serv, New York, NY 10032 USA
关键词
Pedicle screw placement; Thoracic spine; Surgical anatomy; Free hand technique; Surgical technique; Cadaveric study; COMPLICATIONS; LUMBAR; FIXATION;
D O I
10.3340/jkns.2012.51.1.66
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Thoracic pedicle screw fixation techniques are still controversial for thoracic deformities because of possible complications including neurologic deficit. Methods to aid the surgeon in appropriate screw placement have included the use of intraoperative fluoroscopy and/or radiography as well as image-guided techniques. We describe our technique for free hand pedicle screw placement in the thoracic spine without any radiographic guidance and present the results of pedicle screw placement analyzed by computed tomographic scan in two human cadavers. This free hand technique of thoracic pedicle screw placement performed in a step-wise, consistent, and compulsive manner is an accurate, reliable, and safe method of insertion to treat a variety of spinal disorders, including spinal deformity.
引用
收藏
页码:66 / 70
页数:5
相关论文
共 50 条
  • [41] Safe placement of pedicle screw in lumbar spine with minimum three year follow-up: a case series and technical note
    Di Zhang
    Xianda Gao
    Jiang Jiang
    Yong Shen
    Wenyuan Ding
    Huixian Cui
    International Orthopaedics, 2018, 42 : 567 - 573
  • [42] Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
    Wei-Xing Xu
    Wei-Guo Ding
    Bin Xu
    Tian-Hong Hu
    Hong-Feng Sheng
    Jia-Fu Zhu
    Xiao-Long Zhu
    BMC Musculoskeletal Disorders, 21
  • [43] Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
    Xu, Wei-Xing
    Ding, Wei-Guo
    Xu, Bin
    Hu, Tian-Hong
    Sheng, Hong-Feng
    Zhu, Jia-Fu
    Zhu, Xiao-Long
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [44] Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques
    Gelalis, Ioannis D.
    Paschos, Nikolaos K.
    Pakos, Emilios E.
    Politis, Angelos N.
    Arnaoutoglou, Christina M.
    Karageorgos, Athanasios C.
    Ploumis, Avraam
    Xenakis, Theodoros A.
    EUROPEAN SPINE JOURNAL, 2012, 21 (02) : 247 - 255
  • [45] Percutaneous Pedicle Screw Placement in the Lumbar Spine A Comparison Study Between the Novel Guidance System and the Conventional Fluoroscopy Method
    Gu, Guangfei
    Zhang, Hailong
    He, Shisheng
    Cai, Xiaobing
    Gu, Xin
    Jia, Jianbo
    Fu, Qingsong
    Zhou, Xu
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (09): : E522 - E527
  • [46] Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques
    Ioannis D. Gelalis
    Nikolaos K. Paschos
    Emilios E. Pakos
    Angelos N. Politis
    Christina M. Arnaoutoglou
    Athanasios C. Karageorgos
    Avraam Ploumis
    Theodoros A. Xenakis
    European Spine Journal, 2012, 21 : 247 - 255
  • [47] Computed Tomography Based Anatomical Study to Assess Feasibility of Pedicle Screw Placement in the Lumbar and Lower Thoracic Pediatric Spine
    Shaikh, Kashif Ajaz
    Bennett, Garrett
    White, Ian Kainoa
    Bullis, Carli
    Fulkerson, Daniel H.
    NEUROSURGERY, 2012, 71 (02) : E567 - E567
  • [48] Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note
    Satarasinghe, Praveen
    Hamilton, Kojo D.
    Tarver, Michael J.
    Buchanan, Robert J.
    Koltz, Michael T.
    JOURNAL OF CLINICAL MEDICINE, 2018, 7 (04):
  • [49] Morphologic evaluation of the thoracic vertebrae for safe free-hand pedicle screw placement in adolescent idiopathic scoliosis: a CT-based anatomical study
    Guanyu Cui
    Kota Watanabe
    Naobumi Hosogane
    Takashi Tsuji
    Ken Ishii
    Masaya Nakamura
    Yoshiaki Toyama
    Kazuhiro Chiba
    Lawrence G. Lenke
    Morio Matsumoto
    Surgical and Radiologic Anatomy, 2012, 34 : 209 - 216
  • [50] Morphologic evaluation of the thoracic vertebrae for safe free-hand pedicle screw placement in adolescent idiopathic scoliosis: a CT-based anatomical study
    Cui, Guanyu
    Watanabe, Kota
    Hosogane, Naobumi
    Tsuji, Takashi
    Ishii, Ken
    Nakamura, Masaya
    Toyama, Yoshiaki
    Chiba, Kazuhiro
    Lenke, Lawrence G.
    Matsumoto, Morio
    SURGICAL AND RADIOLOGIC ANATOMY, 2012, 34 (03) : 209 - 216