摘要
Severe peak asymmetry -fronting- was observed for oxycodone during elution at 30 degrees C from a C-18 HPLC column using a mobile phase consisting of 14.9% MeOH, 84.5% 0.05 M KH2PO4 (pH 3.0), 0.5% MTBE, and 0.1% TEA. Investigation using deuterium-labeled oxycodone and analysis by LC/MS showed that gem-diol and hemiketal adducts of oxycodone formed as a result of the equilibrium addition of water and methanol to the C-6 ketone on oxycodone. As a result of slow equilibrium kinetics at room temperature in aqueous solution, the gem-diol and methyl hemiketal eluted as an unresolved broad band in front of the oxycodone peak. Decreasing the column temperature to 0 degrees C decreased the rates of interconversion and allowed the resolution and separation of these species from each other and from oxycodone. Increasing the column temperature to 60 degrees C increased the rates of interconversion with the result that the three species eluted as a single, homogenous peak with greatly improved peak symmetry. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:669 / 678
页数:10
相关论文
共 50 条
  • [41] Optimization of chromatographic parameters for the determination of biogenic amines in wines by reversed-phase high-performance liquid chromatography
    Romero, R
    Gázquez, D
    Bagur, MG
    Sánchez-Viñas, M
    JOURNAL OF CHROMATOGRAPHY A, 2000, 871 (1-2) : 75 - 83
  • [42] Simultaneous Prediction of Retention Times and Peak Shapes of Sulfonamides in Reversed-Phase High-Performance Liquid Chromatography
    Wei X.
    Pang Z.
    Fan G.
    Xu X.
    Wang L.
    Transactions of Tianjin University, 2018, 24 (3) : 256 - 262
  • [43] Simultaneous Prediction of Retention Times and Peak Shapes of Sulfonamides in Reversed-Phase High-Performance Liquid Chromatography
    Xiaobing Wei
    Zhengji Pang
    Guoliang Fan
    Xinhua Xu
    Lihong Wang
    Transactions of Tianjin University, 2018, (03) : 256 - 262
  • [44] EFFECTS OF AMINE MODIFIERS ON RETENTION AND PEAK SHAPE IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KIEL, JS
    MORGAN, SL
    ABRAMSON, RK
    JOURNAL OF CHROMATOGRAPHY, 1985, 320 (02): : 313 - 323
  • [45] Simultaneous Prediction of Retention Times and Peak Shapes of Sulfonamides in Reversed-Phase High-Performance Liquid Chromatography
    Xiaobing Wei
    Zhengji Pang
    Guoliang Fan
    Xinhua Xu
    Lihong Wang
    Transactions of Tianjin University, 2018, 24 (03) : 256 - 262
  • [46] Modification of the murakami retention model in reversed-phase high-performance liquid chromatography for micellar chromatographic separations
    L. P. Loginova
    A. P. Boichenko
    A. Yu. Kulikov
    Russian Journal of Physical Chemistry A, Focus on Chemistry, 2008, 82 : 1470 - 1474
  • [47] Modification of the murakami retention model in reversed-phase high-performance liquid chromatography for micellar chromatographic separations
    Loginova, L. P.
    Boichenko, A. P.
    Kulikov, A. Yu.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2008, 82 (09) : 1470 - 1474
  • [48] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF CHLOROPHYLLS AND CAROTENOIDS
    BRAUMANN, T
    GRIMME, LH
    BIOCHIMICA ET BIOPHYSICA ACTA, 1981, 637 (01) : 8 - 17
  • [49] Preparation and separation of metallobacteriochlorophyll a by reversed-phase high-performance liquid chromatography
    Inoue, H
    Nonomura, Y
    Ashizawa, A
    Tajima, I
    Nomura, M
    Nakamura, N
    Yoshioka, N
    CHROMATOGRAPHIA, 1996, 43 (7-8) : 361 - 364
  • [50] FASTER ANALYSIS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MELLOR, N
    CHROMATOGRAPHIA, 1982, 16 : 359 - 363