Experimental Evaluation of the System-Level Seismic Performance and Robustness of an Asymmetrical Reinforced Concrete Block Building

被引:12
|
作者
Ashour, Ahmed [1 ,2 ]
El-Dakhakhni, Wael [3 ,4 ]
Shedid, Marwan [5 ]
机构
[1] Cairo Univ, Fac Engn, Cairo, Egypt
[2] McMaster Univ, Dept Civil Engn, Hamilton, ON L8S 4L7, Canada
[3] McMaster Univ, Dept Civil Engn, Masonry Design, Hamilton, ON L8S 4L7, Canada
[4] McMaster Univ, Dept Civil Engn, Appl Dynam Lab, Hamilton, ON L8S 4L7, Canada
[5] Ain Shams Univ, Dept Struct Engn, Cairo 1156, Egypt
基金
加拿大自然科学与工程研究理事会;
关键词
Concrete and masonry structures; Masonry buildings; Robustness; Seismic loads; Shear walls; Slab coupling; System-level performance; MASONRY SHEAR WALLS;
D O I
10.1061/(ASCE)ST.1943-541X.0001529
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, research interests in studying the response of different seismic force-resisting systems have been shifting from component-level to system-level studies. Building on the existing knowledge of component-level performance of reinforced masonry shear walls (RMSW), the current study evaluates some similarities and discrepancies between RMSW system-level and component-level responses under seismic loading. The study also focuses on evaluating the system-level seismic robustness of a RMSW building by quantifying key relevant robustness indicators proposed in the literature. To meet the study objectives, an experimental asymmetrical two-story reduced-scale RMSW building was tested to failure under simulated seismic loading. Subsequently, the study first presents a brief summary of the experimental program followed by a discussion of the damage sequence and the load-displacement hysteretic behavior of the RMSW building. In general, the experimental results demonstrated the impact of both the floor slab-induced twist and wall flexural coupling through the floor slabs on the building response, with the latter significantly influencing the building response compared to the former. In addition, the robustness indexes quantified for five key robustness indicators (drift ratio, strength, stiffness, strain energy, and residual drift ratio) can provide a means by which the system-level performance of RMSW buildings can be assessed from different perspectives under a wide range of seismic demands.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Experimental evaluation of the seismic performance of reinforced concrete structural walls with different end configurations
    El-Azizy, Omar A.
    Shedid, Marwan T.
    El-Dakhakhni, Wael W.
    Drysdale, Robert G.
    ENGINEERING STRUCTURES, 2015, 101 : 246 - 263
  • [32] Dynamic Modeling of Soil-Structure Interaction for Seismic Performance Evaluation of Reinforced Concrete Building
    Tallah, N.
    Boulaouad, A.
    Berrabah, F.
    JOURNAL OF APPLIED ENGINEERING SCIENCES, 2024, 14 (02) : 342 - 347
  • [33] Seismic Response Analysis of a Reinforced Concrete Block Shear Wall Asymmetric Building
    Heerema, Paul
    Shedid, Marwan
    El-Dakhakhni, Wael
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (07)
  • [34] System-level performance evaluation of reconfigurable processors
    Enzler, R
    Plessl, C
    Platzner, M
    MICROPROCESSORS AND MICROSYSTEMS, 2005, 29 (2-3) : 63 - 73
  • [35] Seismic Performance Evaluation of Reinforced Concrete Frames Subjected to Seismic Loads
    Zameeruddin M.
    Sangle K.K.
    Journal of The Institution of Engineers (India): Series A, 2017, 98 (1-2) : 177 - 183
  • [36] Seismic evaluation and retrofit of a typical reinforced concrete hospital building in Indonesia with DCFP isolation system
    Imran, Iswandi
    Siringoringo, Dionysius M.
    Rainayana, Salma S.
    STRUCTURES, 2024, 64
  • [37] Seismic performance of reinforced concrete building frames on sloping ground retrofitted with steel and reinforced concrete jacketing
    Dey, Mithu
    Chakraborty, Subrata
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2024, 9 (11)
  • [38] . Experimental study on seismic performance of fiber reinforced concrete pier
    Lan, Feng
    Li, Qian
    Chen, Zhuoyi
    Ma, Wengang
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 1791 - +
  • [39] Seismic performance of an instrumented ten-storey reinforced concrete building
    Miranda, E
    Bertero, VV
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1996, 25 (10): : 1041 - 1059
  • [40] Seismic performance of reinforced concrete building in Guwahati city, northeast India
    Ghosh, S.
    Chakraborty, S.
    SCIENTIA IRANICA, 2017, 24 (04) : 1821 - 1833