3D printed fracture reduction guides planned and printed at the point of care show high accuracy - a porcine feasibility study

被引:4
|
作者
Hecker, Andreas [1 ]
Eberlein, Sophie C. [1 ]
Klenke, Frank M. [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Orthopaed Surg & Traumatol, Inselspital, Freiburgstr 4, CH-3010 Bern, Switzerland
关键词
3D print; 3D reconstruction; Diaphyseal fracture; Comminuted fracture; Malalignment; Malrotation; LIMB MALROTATION; ANTEVERSION; LENGTH;
D O I
10.1186/s40634-022-00535-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: After surgical treatment of comminuted diaphyseal femoral and tibial fractures, relevant malalignment, especially rotational errors occur in up to 40-50%. This either results in a poor clinical outcome or requires revision surgery. This study aims to evaluate the accuracy of reduction if surgery is supported by 3D guides planned and printed at the point of care. Methods: Ten porcine legs underwent computed tomography (CT) and 3D models of femur and tibia were built. Reduction guides were virtually constructed and fitted to the proximal and distal metaphysis. The guides were 3D printed using medically approved resin. Femoral and tibial comminuted diaphyseal fractures were simulated and subsequently reduced using the 3D guides. Postoperative 3D bone models were reconstructed to compare the accuracy to the preoperative planning. Results: Femoral reduction showed a mean deviation +/- SD from the plan of 1.0mm +/- 0.9 mm for length, 0.9 degrees +/- 0.7 degrees for varus/valgus, 1.2 degrees +/- 0.9 degrees for procurvatum/recurvatum and 2.0 degrees +/- 1.7 degrees for rotation. Analysis of the tibial reduction revealed a mean deviation +/- SD of 2.4 mm +/- 1.6 mm for length, 1.0 degrees +/- 0.6 degrees for varus/valgus, 1.3 degrees +/- 1.4 degrees for procurvatum/recurvatum and 2.9 degrees +/- 2.2 degrees for rotation. Conclusions: This study shows high accuracy of reduction with 3D guides planned and printed at the point of care. Applied to a clinical setting, this technique has the potential to avoid malreduction and consecutive revision surgery in comminuted diaphyseal fractures.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Experimental study on fracture infiltration and slurry permeation reduction based on 3D printed visualization models
    Wang, Bingzhu
    Qian, Ziwei
    Tan, Chunzhi
    Liu, Jufeng
    ENVIRONMENTAL EARTH SCIENCES, 2024, 83 (13)
  • [32] Accuracy of Implant Placement Utilizing 3D Printed and Thermoplastic Surgical Guides: A CBCT-Analysis
    Al-Hamdan, Khalid
    Al Oaibi, Abdulrahman
    AlWadai, Turki
    Al-Fadda, Abdullah
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (03): : 1210 - 1213
  • [33] Study on the use of 3D printed guides in the individualized reconstruction of the anterior cruciate ligament
    Xin Wang
    Dening Wang
    Chenchen Zhang
    Kefan Zhang
    Changling Du
    Hui Shi
    BMC Musculoskeletal Disorders, 25
  • [34] Study on the use of 3D printed guides in the individualized reconstruction of the anterior cruciate ligament
    Wang, Xin
    Wang, Dening
    Zhang, Chenchen
    Zhang, Kefan
    Du, Changling
    Shi, Hui
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [35] Fracture toughness of 3D printed denture teeth
    Alqahtani, Nasser M.
    Chaturvedi, Saurabh
    Tomar, Shobhit Singh
    Kumari, Lalima
    Gill, Shruti
    Nayan, Kamal
    Shariff, Mansoor
    Bhagat, Tushar, V
    Addas, Mohammed Khalid
    Chaturvedi, Mudita
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (01) : 247 - 258
  • [36] Accuracy and feasibility in building a personalized 3D printed femoral pseudoaneurysm model for endovascular training
    Lee, Suat Yee
    Chew, Shen Cheak Currina
    Lee, Pei Hua
    Chen, Hung Da
    Huang, Shao Min
    Liu, Chun Hung
    Chew, Fatt Yang
    PLOS ONE, 2024, 19 (06):
  • [37] Feasibility study of hydrocolloid incorporated 3D printed pork as dysphagia food
    Dick, Arianna
    Bhandari, Bhesh
    Dong, Xiuping
    Prakash, Sangeeta
    FOOD HYDROCOLLOIDS, 2020, 107
  • [38] Bioengineered, 3D printed Vascular Constructs in the Porcine Model
    Galvan, N. Thao
    Paulsen, Samantha
    Yoeli, Dor
    Marini, Juan
    Grigoryan, Bagrat
    Sazer, Daniel
    Rana, Abbas
    Goss, John
    Miller, Jordan
    AMERICAN JOURNAL OF TRANSPLANTATION, 2018, 18 : 19 - 20
  • [39] Methodology and feasibility of a 3D printed assistive technology intervention
    Schwartz, Jaclyn K.
    Fermin, Angelica
    Fine, Kimberly
    Iglesias, Nathalie
    Pivarnik, Danika
    Struck, Stephanie
    Varela, Natalie
    Janes, William E.
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2020, 15 (02) : 141 - 147
  • [40] Correction: Accuracy of guide wire placement for femoral neck stabilization using 3D printed drill guides
    Gregory R. Roytman
    Alim F. Ramji
    Brian Beitler
    Brad Yoo
    Michael P. Leslie
    Michael Baumgaertner
    Steven Tommasini
    Daniel H. Wiznia
    3D Printing in Medicine, 8