Reproducibility of cerebral tissue oxygen saturation measurements by near-infrared spectroscopy in newborn infants

被引:31
|
作者
Jenny, Carmen [1 ]
Biallas, Martin [1 ,2 ,3 ]
Trajkovic, Ivo [1 ,2 ,3 ]
Fauchere, Jean-Claude [1 ]
Bucher, Hans Ulrich [1 ]
Wolf, Martin [1 ]
机构
[1] Univ Zurich Hosp, Biomed Opt Res Lab, Div Neonatol, Dept Obstet & Gynecol, CH-8091 Zurich, Switzerland
[2] Univ Zurich, CH-8093 Zurich, Switzerland
[3] Swiss Fed Inst Technol, Inst Biomed Engn, CH-8093 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
tissue oxygen saturation; near-infrared spectroscopy; reproducibility; neonate; within-infant variation; between-infant variation; NEONATAL HEAD PHANTOM; PRETERM; ADULTS; INDEX; BRAIN;
D O I
10.1117/1.3622756
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Early detection of cerebral hypoxemia is an important aim in neonatology. A relevant parameter to assess brain oxygenation may be the cerebral tissue oxygen saturation (StO(2)) measured by near-infrared spectroscopy (NIRS). So far the reproducibility of StO(2) measurements was too low for clinical application, probably due to inhomogeneities. The aim of this study was to test a novel sensor geometry which reduces the influence of inhomogeneities. Thirty clinically stable newborn infants, with a gestational age of median 33.9 (range 26.9 to 41.9) weeks, birth weight of 2220 (820 to 4230) g, postnatal age of 5 (1 to 71) days were studied. At least four StO(2) measurements of 1 min duration were carried out using NIRS on the lateral head. The sensor was repositioned between measurements. Reproducibility was calculated by a linear mixed effects model. The mean StO(2) was 79.99 +/- 4.47% with a reproducibility of 2.76% and a between-infant variability of 4.20%. Thus, the error of measurement only accounts for 30.1% of the variability. The novel sensor geometry leads to considerably more precise measurements compared to previous studies with, e.g., similar to 5% reproducibility for the NIRO 300. The novel StO2 values hence have a higher clinical relevance. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3622756]
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Tissue oxygen index - Thresholds for cerebral ischemia using near-infrared spectroscopy
    Al-Rawi, Pippa G.
    Kirkpatrick, Peter J.
    STROKE, 2006, 37 (11) : 2720 - 2725
  • [32] Alkaptonuric Ochronosis and the Failure of Regional Cerebral Tissue Oxygen Saturation Monitoring by Two Different Near-infrared Spectroscopy Devices
    Namekawa, Motoki
    Ishida, Kazuyoshi
    Kimura, Motoko
    Fujii, Chiaki
    Yamashita, Shigeki
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (05) : 2286 - 2288
  • [33] Usefulness of near-infrared spectroscopy for monitoring a cerebral tissue oxygen saturation during cardio-pulmonary resuscitation (CPR)
    M Homma
    H Henmi
    Y Otomo
    J Inoue
    K Mashiko
    Y Yamamoto
    T Otsuka
    Critical Care, 1 (Suppl 1):
  • [34] A Meta-Analysis for effects of patent ductus arteriosus on regional cerebral oxygen saturation and fractional tissue oxygen extraction in preterm infants using near-infrared spectroscopy
    Schwarz, C. E.
    Neunhoeffer, F.
    Bassler, D.
    Poets, C. F.
    Franz, A. R.
    EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (11) : 1708 - 1708
  • [35] Near-infrared spectroscopy measurements of cerebral blood flow and oxygen consumption following hypoxia-ischemia in newborn piglets
    Tichauer, KM
    Brown, DW
    Hadway, J
    Lee, TY
    St Lawrence, K
    JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (03) : 850 - 857
  • [36] Near-infrared spectroscopy measurement of oxygen extraction fraction and cerebral metabolic rate of oxygen in newborn piglets
    Brown, DW
    Hadway, J
    Lee, TY
    PEDIATRIC RESEARCH, 2003, 54 (06) : 861 - 867
  • [37] MEASUREMENT OF OPTICAL-PATH LENGTH FOR CEREBRAL NEAR-INFRARED SPECTROSCOPY IN NEWBORN-INFANTS
    WYATT, JS
    COPE, M
    DELPY, DT
    VANDERZEE, P
    ARRIDGE, S
    EDWARDS, AD
    REYNOLDS, EOR
    DEVELOPMENTAL NEUROSCIENCE, 1990, 12 (02) : 140 - 144
  • [38] Near-Infrared Spectroscopy Measurement of Oxygen Extraction Fraction and Cerebral Metabolic Rate of Oxygen in Newborn Piglets
    Derek W Brown
    Jennifer Hadway
    Ting-Yim Lee
    Pediatric Research, 2003, 54 : 861 - 867
  • [39] Correlation of brain tissue oxygen tension with cerebral near-infrared spectroscopy and mixed venous oxygen saturation during extracorporeal membrane oxygenation
    Tyree, Kreangkai
    Tyree, Melissa
    DiGeronimo, Robert
    PERFUSION-UK, 2009, 24 (05): : 325 - 331
  • [40] Measurement of cerebral oxyhaemoglobin saturation and jugular blood flow in term healthy newborn infants by near-infrared spectroscopy and jugular venous occlusion
    Buchvald, FF
    Kesje, K
    Greisen, G
    BIOLOGY OF THE NEONATE, 1999, 75 (02): : 97 - 103