Research on the discharge characteristics of XLPE insulated DC cables

被引:0
|
作者
Liu, Ying [1 ]
Zheng, Xinlong [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
[2] State Grid Corp, Zhoushan Power Supply Co, Zhoushan 316021, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1063/5.0077821
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper focuses on the discharge of cross-linked polyethylene (XLPE) insulated DC cables, which has become a concern of power utilities when carrying out a voltage withstand test or an outage maintenance. Based on the electrical tree initiation test of XLPE block samples under grounded DC voltages, the main cause and key factors for damages of DC insulation resulted by grounding discharge were investigated, and the allowable voltage level to start the accelerated discharge operation was estimated. By the laboratory tests of two XLPE cable samples discharged under different conditions, the basic discharge rules were observed, the equivalent circuit was set up, and the equipment parameters were determined. In addition, a method to estimate the discharge time for cable lines with different lengths was proposed. Finally, the on-site measured data of decay voltage and leakage current were presented for a 200 kV DC XLPE cable line which had been discharged steppedly through a resistance grounding device after the DC voltage withstand test, and the experimental results were found to be in good agreement with the theoretical data.(c) 2021 Author(s).
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Influence of conditioning and features on the electrical breakdown of XLPE insulated power cables
    Kryszak, B
    Jenkins, N
    Le Poidevin, G
    Naybour, RD
    2000 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS. I & II, 2000, : 608 - 612
  • [22] INSULATION PROPERTIES OF 250 KV DC XLPE CABLES
    FUKAGAWA, H
    MIYAUCHI, H
    YAMADA, Y
    YOSHIDA, S
    ANDO, N
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (07): : 3175 - 3184
  • [23] Comprehensive Evaluation of Insulation Performance of DC XLPE Cables
    Li Ji
    Wang Haoming
    He Xin
    Chen Lei
    Zhang Chi
    Zhang Yingtian
    Li Xu
    Yu Yang
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 238 - 243
  • [24] Basic study on polymer-insulated DC cable - The effect of the morphology on the interface on DC characteristics of cables
    Uchida, K
    Yamamoto, M
    Kawashima, T
    Uozumi, T
    Inoue, Y
    Hata, R
    JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 89 - 92
  • [25] Overview of partial discharge detection methods for XLPE cables
    Wang, Xiaodi
    Zhou, Hong
    Yu, Jinhua
    Xu, Qiang
    Yang, Tianyu
    Zhou, Yunjie
    Yuan, Jialiang
    PROCEEDINGS OF 2024 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ARTIFICIAL INTELLIGENCE, PEAI 2024, 2024, : 46 - 52
  • [26] Application of Correlation Analysis Techniques in Feature Extraction and Selection for DC Partial Discharge Signals of XLPE Cables
    Yang F.
    Xu Y.
    Qian Y.
    Li Z.
    Sheng G.
    Jiang X.
    Dianwang Jishu/Power System Technology, 2018, 42 (05): : 1653 - 1660
  • [27] On-line partial discharge detection in XLPE cables
    Luo, Junhua
    Ma, Cuijiao
    Qiu, Yuchang
    Gaodianya Jishu/High Voltage Engineering, 1999, 25 (04): : 32 - 34
  • [28] ELECTRICAL BREAKDOWN CHARACTERISTICS AND TESTING OF HIGH-VOLTAGE XLPE AND ELECTRON-PARAMAGNETIC-RES INSULATED CABLES
    BAHDER, G
    SOSNOWSKI, M
    KATZ, C
    EATON, R
    KLEIN, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (07): : 2173 - 2185
  • [29] Partial Discharge Characteristics of DC Electrical Tree in XLPE During Voltage Drop
    Lin G.
    Zhang H.
    Zheng Z.
    Wang Y.
    Zhou M.
    Yin Y.
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (01): : 348 - 358
  • [30] Partial Discharge Characteristics of Typical Defects in XLPE Cable Under DC Voltage
    Du H.
    Guan H.
    Chen X.
    Hou S.
    Yang M.
    Wang X.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (02): : 555 - 563