Research on the discharge characteristics of XLPE insulated DC cables

被引:0
|
作者
Liu, Ying [1 ]
Zheng, Xinlong [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
[2] State Grid Corp, Zhoushan Power Supply Co, Zhoushan 316021, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1063/5.0077821
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper focuses on the discharge of cross-linked polyethylene (XLPE) insulated DC cables, which has become a concern of power utilities when carrying out a voltage withstand test or an outage maintenance. Based on the electrical tree initiation test of XLPE block samples under grounded DC voltages, the main cause and key factors for damages of DC insulation resulted by grounding discharge were investigated, and the allowable voltage level to start the accelerated discharge operation was estimated. By the laboratory tests of two XLPE cable samples discharged under different conditions, the basic discharge rules were observed, the equivalent circuit was set up, and the equipment parameters were determined. In addition, a method to estimate the discharge time for cable lines with different lengths was proposed. Finally, the on-site measured data of decay voltage and leakage current were presented for a 200 kV DC XLPE cable line which had been discharged steppedly through a resistance grounding device after the DC voltage withstand test, and the experimental results were found to be in good agreement with the theoretical data.(c) 2021 Author(s).
引用
收藏
页数:9
相关论文
共 50 条
  • [1] STUDY ON THE DIELECTRIC CHARACTERISTICS OF DC XLPE CABLES
    OGATA, S
    MAEKAWA, Y
    TERASHIMA, K
    OKIAI, R
    YOSHIDA, S
    YAMANOUCHI, H
    YOKOYAMA, S
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (03) : 1239 - 1247
  • [2] Research and development of ±250 kV DC XLPE cables
    Terashima, K
    Suzuki, H
    Hara, M
    Watanabe, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (01) : 7 - 16
  • [3] Effect of Thickness on DC Breakdown Weibull Distribution of XLPE Insulated Cables at High Temperature
    Zhu, Minhui
    Min, Daomin
    Lin, Songjia
    Wang, Shihang
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (21): : 6908 - 6920
  • [4] A CONTRIBUTION TO THE STUDY OF AGING OF XLPE INSULATED CABLES
    MOTORI, A
    SANDROLINI, F
    MONTANARI, GC
    IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (01) : 34 - 42
  • [5] Quantifying degradation of XLPE insulated distribution cables
    Dalal, SB
    Gorur, RS
    Dyer, ML
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 1841 - 1845
  • [6] Simulation of Partial Discharge Propagation Characteristics in XLPE Cables and joints
    Liu, Bin
    Yang, Yuqi
    Chen, Xiping
    Sun, Zhenquan
    Li, Hongjie
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 1436 - +
  • [7] THERMAL ENDURANCE EVALUATION OF XLPE INSULATED CABLES
    MONTANARI, GC
    MOTORI, A
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1991, 24 (07) : 1172 - 1181
  • [8] Partial Discharge Characteristics of Electrical trees in XLPE Power Cables
    Zhou, Tianchun
    Yang, Lijun
    Liao, Ruijin
    Zhou, Quan
    Ye, Di
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 93 - 96
  • [9] Classification of Partial Discharge Images within DC XLPE Cables in Contourlet Domain
    Xu, Yongpeng
    Sheng, Gehao
    Yang, Fengyuan
    Chen, Xiaoxin
    Qian, Yong
    Jiang, Xiuchen
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (02) : 486 - 493
  • [10] DEVELOPMENT OF XLPE INSULATED DC CABLE
    MAEKAWA, Y
    YAMAGUCHI, A
    HARA, M
    SEKII, Y
    ELECTRICAL ENGINEERING IN JAPAN, 1994, 114 (08) : 1 - 12