Lightning Protection System on Overhead Distribution Line Using Multi Chamber Arrester

被引:0
|
作者
Perdana, Erlangga [1 ]
Hidayat, Syarif [1 ]
Zoro, Reynaldo [1 ]
机构
[1] Bandung Inst Technol, Lightning Res Ctr, Sch Elect Engn & Informat, Bandung, Indonesia
关键词
Multi Chamber Arrester; 20 kV overhead line; line fault of feeder Ruko;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
New innovation on arrester technology has been made by appearance of Multi Chamber Arrester (MCA). This kind of arrester has basic principle similar to previous technology which use air gap and air pressure in chamber as its technology. MCA has a function to protect overhead line from lightning. For instance, 20 kV medium voltage overhead line. Field testing has been set up to get analysis on MCA. Field testing has been done on 20 kV medium voltage overhead line of feeder Ruko of PLN Serpong. After a certain period of installation, line fault pattern of feeder Ruko is then captured to get the analysis. The analysis is used to get conclusions whether MCA is appropriate for lightning protection system on 20 kV overhead lines.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 50 条
  • [21] A protocol for selecting viable transmission line arrester for optimal lightning protection
    Ahmed, Nasiru Yahaya
    Illias, Hazlee Azil
    Mokhlis, Hazlie
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 221
  • [22] LIGHTNING ARRESTER FAILURE AND FERRORESONANCE ON A DISTRIBUTION-SYSTEM
    BOHMANN, LJ
    MCDANIEL, J
    STANEK, EK
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1993, 29 (06) : 1189 - 1195
  • [23] Research on lightning protection of overhead power distribution lines
    Yokoyama, Shigeru
    Sato, Tomoyuki
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (10): : 2317 - 2328
  • [24] Simulation Study on Lightning Protection of Distribution Transformer with Zinc Oxide Arrester
    Hou, Mengqian
    Gao, Houlei
    Zhang, Shuai
    Wang, Fei
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1763 - 1767
  • [25] Lightning Protection of Distribution Power Systems: Arrester Development and Application Over the Years
    Woodworth, Jonathan
    IEEE POWER & ENERGY MAGAZINE, 2023, 21 (02): : 51 - 60
  • [26] Practical Lightning Protection Design for Overhead Power Distribution Lines
    Yokoyama, Shigeru
    Sato, Tomoyuki
    Takahashi, Akihisa
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 789 - 795
  • [27] Modeling of Currents and Voltages in the Lightning Protection System of a Residential Building and an Attached Overhead Power Line
    Maslowski, Grzegorz
    Wyderka, Stanislaw
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2020, 62 (05) : 2164 - 2173
  • [28] Research on Differentiated Lightning Protection of Overhead Distribution Lines under Continuous Lightning Strikes
    Li, Duanjiao
    Sun, Wenxing
    Song, Kunyu
    Zhu, Ruifeng
    Zhong, Zhenxin
    Ding, Tongshu
    Gao, Jiachen
    ENERGIES, 2024, 17 (18)
  • [29] Minimum Distance of Lightning Protection Between Insulator String and Line Surge Arrester in Parallel
    He, Jinliang
    Hu, Jun
    Chen, Yonghua
    Chen, Shuiming
    Zeng, Rong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (02) : 656 - 663
  • [30] On the Lightning Induced Voltage Along Overhead Power Distribution Line
    Izadi, Mahdi
    Ab Kadir, Mohd Zainal Abidin
    Hajikhani, Maryam
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (05) : 1694 - 1703