Microtensile vs Microshear Bond Strength of All-in-One Adhesives to Unground Enamel

被引:31
|
作者
Beloica, Milos [1 ,2 ]
Goracci, Cecilia [2 ]
Ramos Carvalho, Carlos Augusto [2 ,3 ]
Radovic, Ivana [2 ]
Margvelashvili, Mariam [2 ]
Vulicevic, Zoran R. [1 ]
Ferrari, Marco [2 ]
机构
[1] Univ Belgrade, Fac Dent, Clin Pediat & Prevent Dent, Dept Pedodont, Molerova 66, Belgrade 11000, Serbia
[2] Univ Siena, Policlin Le Scotte, Dept Dent Mat, I-53100 Siena, Italy
[3] Univ Sao Paulo, Bauru Sch Dent, Dept Operat Dent, BR-05508 Sao Paulo, Brazil
来源
JOURNAL OF ADHESIVE DENTISTRY | 2010年 / 12卷 / 06期
关键词
all in one adhesives; unground enamel microtensile; microshear bond strength test; SELF-ETCH ADHESIVES; PRISM ORIENTATION; PHOSPHORIC-ACID; TENSILE; INTEGRITY; SHEAR; RESIN; AGGRESSIVENESS; COMPOSITE; SYSTEMS;
D O I
10.3290/j.jad.a18237
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To determine the bond strength to unground enamel of all in one adhesives in comparison with an etch and rinse system and to compare the reliability of microtensile and microshear methods in providing such measurements Materials and Methods The bonding procedure was performed on enamel of 64 extracted molars The tested all in one adhesives were Bond Force (Tokuyama), AdheSE One (Ivoclar Vivadent) and Xeno V (Dentsply) Prime&Bond NT (Dentsply) served as control Microtensile specimens were obtained from 4 teeth per group Twelve teeth per group were used for microshear testing Microtensile specimens that failed prior to testing were included in statistical calculations, they were assigned the lowest value measured in the respective group Failure modes were observed under light microscope and classified (cohesive within substrates, adhesive mixed) Statistically significant differences in bond strength were assessed among the adhesives within each testing method and between microshear and microtensile data for each adhesive Failure mode distributions were compared using the chi square test Results All in-one adhesives had similar microshear and microtensile bond strengths In both testing methods, the etch and rinse system achieved the strongest bond For all adhesives significantly higher bond strengths were measured with the microshear test In microtensile testing specimens bonded with the etch and rinse adhesive exhibited a significantly different distribution of failure modes The coefficients of variation were extremely high for microtensile bond strength data, particularly of all in one adhesives Conclusion The adhesive potential to intact enamel of recently introduced all in-one adhesives was inferior to that of an etch and rinse system When testing bond strength to enamel of all in one adhesives, microshear testing may be a more accurate method than microtensile
引用
收藏
页码:427 / 433
页数:7
相关论文
共 50 条
  • [31] Microtensile bond strength and micromorphology of two one-bottle dentin adhesives.
    Xie, B
    Dickens, SH
    Giuseppetti, AA
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 374 - 374
  • [32] Shear bond strength of one-bottle adhesives to enamel.
    Giannini, M
    Marchi, GM
    Pimenta, LAF
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1143 - 1143
  • [33] Reliability and correlation between microshear and microtensile bond strength tests of composite repairs
    Fornazari, Isabelle Adad
    Brum, Rafael Torres
    Rached, Rodrigo Nunes
    de Souza, Evelise Machado
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 103
  • [34] Relation of enamel prism orientation to microtensile bond strength
    Ikeda, T
    Uno, S
    Tanaka, T
    Kawakami, S
    Komatsu, H
    Sano, H
    AMERICAN JOURNAL OF DENTISTRY, 2002, 15 (02): : 109 - 113
  • [35] Micro-Tensile Dentin Bond Strength of Two All-in-One Adhesives and an Etch-and-Rinse Adhesive
    Caglar, Esber
    Kuvvetli, Senem
    Cildir, Sule
    Kuscu, Ozgur O.
    Alp, Fatos
    Sandalli, Nuket
    ACTA STOMATOLOGICA CROATICA, 2010, 44 (02) : 90 - 95
  • [36] Microtensile vs. Flexural Bond Strength for Bond Strength Assessment
    Elkassaby, Annan Ahmed
    Kandil, Mohamed M.
    Alian, Ghada Atef
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (08): : 53 - +
  • [37] MICROTENSILE BOND STRENGTH OF SELF-ETCHING ADHESIVES TO DENTIN
    Vulicevic, Zoran R.
    Radovic, Ivana
    Cury, Alvaro Hafiz
    Krstanovic, Goranka
    Mandic, Jelena
    Ferrari, Marco
    METALLURGICAL & MATERIALS ENGINEERING, 2008, 14 (02) : 101 - 109
  • [39] Effect of universal adhesives on microtensile bond strength to hybrid ceramic
    Mohamed M. Awad
    Lamees Albedaiwi
    Ahmed Almahdy
    Rawaiz Khan
    Nick Silikas
    Muhanad M. Hatamleh
    Fahad M. Alkhtani
    Ali Alrahlah
    BMC Oral Health, 19
  • [40] The Effect of Endodontic Irrigants on the Microtensile Bond Strength of Dentin Adhesives
    Yurdaguven, Haktan
    Tanalp, Jale
    Toydemir, Burcu
    Mohseni, Kambiz
    Soyman, Muebin
    Bayirli, Guenduez
    JOURNAL OF ENDODONTICS, 2009, 35 (09) : 1259 - 1263