Microtensile vs Microshear Bond Strength of All-in-One Adhesives to Unground Enamel

被引:31
|
作者
Beloica, Milos [1 ,2 ]
Goracci, Cecilia [2 ]
Ramos Carvalho, Carlos Augusto [2 ,3 ]
Radovic, Ivana [2 ]
Margvelashvili, Mariam [2 ]
Vulicevic, Zoran R. [1 ]
Ferrari, Marco [2 ]
机构
[1] Univ Belgrade, Fac Dent, Clin Pediat & Prevent Dent, Dept Pedodont, Molerova 66, Belgrade 11000, Serbia
[2] Univ Siena, Policlin Le Scotte, Dept Dent Mat, I-53100 Siena, Italy
[3] Univ Sao Paulo, Bauru Sch Dent, Dept Operat Dent, BR-05508 Sao Paulo, Brazil
来源
JOURNAL OF ADHESIVE DENTISTRY | 2010年 / 12卷 / 06期
关键词
all in one adhesives; unground enamel microtensile; microshear bond strength test; SELF-ETCH ADHESIVES; PRISM ORIENTATION; PHOSPHORIC-ACID; TENSILE; INTEGRITY; SHEAR; RESIN; AGGRESSIVENESS; COMPOSITE; SYSTEMS;
D O I
10.3290/j.jad.a18237
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To determine the bond strength to unground enamel of all in one adhesives in comparison with an etch and rinse system and to compare the reliability of microtensile and microshear methods in providing such measurements Materials and Methods The bonding procedure was performed on enamel of 64 extracted molars The tested all in one adhesives were Bond Force (Tokuyama), AdheSE One (Ivoclar Vivadent) and Xeno V (Dentsply) Prime&Bond NT (Dentsply) served as control Microtensile specimens were obtained from 4 teeth per group Twelve teeth per group were used for microshear testing Microtensile specimens that failed prior to testing were included in statistical calculations, they were assigned the lowest value measured in the respective group Failure modes were observed under light microscope and classified (cohesive within substrates, adhesive mixed) Statistically significant differences in bond strength were assessed among the adhesives within each testing method and between microshear and microtensile data for each adhesive Failure mode distributions were compared using the chi square test Results All in-one adhesives had similar microshear and microtensile bond strengths In both testing methods, the etch and rinse system achieved the strongest bond For all adhesives significantly higher bond strengths were measured with the microshear test In microtensile testing specimens bonded with the etch and rinse adhesive exhibited a significantly different distribution of failure modes The coefficients of variation were extremely high for microtensile bond strength data, particularly of all in one adhesives Conclusion The adhesive potential to intact enamel of recently introduced all in-one adhesives was inferior to that of an etch and rinse system When testing bond strength to enamel of all in one adhesives, microshear testing may be a more accurate method than microtensile
引用
收藏
页码:427 / 433
页数:7
相关论文
共 50 条
  • [1] Microtensile bond strength and sealing efficiency of all-in-one self-etching adhesives
    Tekce, Neslihan
    Demirci, Mustafa
    Tuncer, Safa
    Uysal, Omer
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2015, 29 (03) : 570 - 578
  • [2] Micro-shear bond strength of two all-in-one adhesive systems to unground fluorosed enamel
    Ratnaweera, Priyadarshanee Manorika
    Nikaido, Toru
    Weerasinghe, Dinesh
    Wettasinghe, Kamal Anuradha
    Miura, Hiroyuki
    Tagami, Junji
    DENTAL MATERIALS JOURNAL, 2007, 26 (03) : 355 - 360
  • [3] Influence of hydrostatic pulpal pressure on the microtensile bond strength of all-in-one self-etching adhesives
    Hosaka, Keiichi
    Nakajima, Masatoshi
    Monticelli, Francesca
    Carrilho, Marcela
    Yamauti, Monica
    Aksornmuang, Juthatip
    Nishitani, Yoshihiro
    Tayh, Franklin R.
    Pashley, David H.
    Tagami, Junji
    JOURNAL OF ADHESIVE DENTISTRY, 2007, 9 (05): : 437 - 442
  • [4] Microtensile bond strength of eleven contemporary adhesives to enamel
    Inoue, S
    Vargas, MA
    Abe, Y
    Yoshida, Y
    Lambrechts, P
    Vanherle, G
    Sano, H
    Van Meerbeek, B
    AMERICAN JOURNAL OF DENTISTRY, 2003, 16 (05): : 329 - 334
  • [5] Microtensile versus microshear bond strength between dental adhesives and the dentin substrate
    Muenchow, Eliseu A.
    Bossardi, Mayara
    Priebe, Tanize C.
    Valente, Lisia L.
    Zanchi, Cesar H.
    Ogliari, Fabricio A.
    Piva, Evandro
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2013, 46 : 95 - 99
  • [6] Microtensile bond strength of one bottle and all in one adhesives to human teeth.
    Bouillaguet, S
    Genovese, T
    Cattani, M
    Godin, CH
    Meyer, JM
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B276 - B276
  • [7] Effect of Different Application Techniques of All-in-One Adhesives on Microtensile Bond Strength to Sound and Caries-Affected Dentin
    Tekce, Neslihan
    Demirci, Mustafa
    Tuncer, Safa
    Uysal, Omer
    JOURNAL OF ADHESION, 2015, 91 (04): : 245 - 261
  • [8] Microshear bond strength to dentin of self-adhesive flowable composite compared with total-etch and all-in-one adhesives
    Bumrungruan, Chonlaya
    Sakoolnamarka, Rangsima
    JOURNAL OF DENTAL SCIENCES, 2016, 11 (04) : 449 - 456
  • [9] In vitro bonding performance of all-in-one adhesives. Part I - Microtensile bond strengths
    Perdigao, Jorge
    Gomes, George
    Gondo, Renata
    Fundingsland, Jon W.
    JOURNAL OF ADHESIVE DENTISTRY, 2006, 8 (06): : 367 - 373
  • [10] Efficacy of microtensile versus microshear bond testing for evaluation of bond strength of dental adhesive systems to enamel
    El Zohairy, Ahmed A.
    Saber, Mohamed H.
    Abdalla, Ali I.
    Feilzer, Albert J.