Effects of ultrasound on maternal-fetal bonding: a comparison of two- and three-dimensional imaging

被引:61
|
作者
Ji, EK
Pretorius, DH
Newton, R
Uyan, K
Hull, AD
Hollenbach, K
Nelson, TR
机构
[1] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92037 USA
[2] Univ Calif San Diego, Dept Reprod Med, La Jolla, CA 92037 USA
[3] Univ Calif San Diego, Dept Family & Prevent Med, La Jolla, CA 92037 USA
[4] St Vincent de Paul Village, San Diego, CA USA
[5] Pochon CHA Univ, CHA Gen Hosp, Dept Radiol, Seoul, South Korea
关键词
fetus; maternal-fetal bonding; three-dimensional; ultrasonography;
D O I
10.1002/uog.1896
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives The purpose of this study was to evaluate the effect of two-dimensional (2DUS) compared to three-dimensional ultrasound (3 DUS) imaging on the maternal-fetal bonding process. Methods Fifty mothers who bad 2DUS and 50 who bad 2DUS and 3DUS were included in the study. A postpartum survey by telephone interview was carried out to assess maternal-fetal bonding. Bonding was evaluated by analysis of extent of prenatal image sharing, maternal ability to form a mental picture of the baby, and mother's comments about their ultrasound images. Data were analyzed using the independent t-test, Chi-square and Mann - Whitney U-tests. Results Mothers who received 3DUS showed their ultrasound images to more people (median, 27.5; interquartile range, 14.5-40.0) than mothers receiving 2DUS alone (median, 11.0; interquartile range, 5.0-25.5) (P < 0.001, Z = -3.539). Eighty-two percent of the subjects screened with 3DUS bad a greater tendency to form a mental Picture of the baby postexamination compared to 39% of the 2DUS subjects (P < 0.001, Z = -3.614). Mothers receiving a 3DUS study, were more likely to receive comments on the similarities/differences of the neonate compared to those having 2DUS studies. Furthermore, 70% of the mothers receiving 3DUS felt they 'knew' the baby immediately after birth vs. 56% of the mothers receiving 2DUS (P = 0.009, Z = -2.613). Both 2DUS and 3DUS experiences were positive, however, the comments made by the mothers undergoing 3DUS (n = 18) were more exclamatory (amazed, wonderful, fabulous) than those undergoing 2DUS (n = 4). Patients having a 3DUS examination consistently scored higher than those having a 2DUS examination alone for all categories of maternal-fetal bonding. Conclusion 3DUS appears to more positively, influence the perceptions of mothers to their babies postbirth compared to 2DUS. Specifically, mothers who had 3D US showed their ultrasound images to a greater number of people compared to mothers who had 2DUS alone and this may represent mother's social support system. 3DUS may have a greater impact on the maternal-fetal bonding process. Copyright (c) 2005 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:473 / 477
页数:5
相关论文
共 50 条
  • [41] Imaging surface spectroscopy for two- and three-dimensional characterization of materials
    Hutter, H
    Brunner, C
    Nikolov, S
    Mittermayer, C
    Grasserbauer, H
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 355 (5-6): : 585 - 590
  • [42] Accuracy of three-dimensional automated ultrasound imaging of the fetal brain
    Pluym, Ilina D.
    Kwan, Lorna
    Bolagani, Aswani
    Afshar, Yalda
    Holliman, Kerry
    Wong, Thalia
    Han, Christina S.
    Platt, Lawrence D.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (01) : S641 - S641
  • [43] Evaluation of vascular injury following percutaneous transluminal coronary angioplasty: a comparison of the accuracy of two- and three-dimensional intracoronary ultrasound imaging
    Palmer, ND
    Lessells, A
    Northridge, DB
    Fox, KAA
    CORONARY ARTERY DISEASE, 2003, 14 (03) : 255 - 262
  • [44] Comparison of viscoelastic flows in two- and three-dimensional serpentine channels
    Garg, Himani
    Fureby, Christer
    PHYSICAL REVIEW E, 2024, 109 (05)
  • [45] Comparison of two- and three-dimensional measurement of the Cobb angle in scoliosis
    Lechner, Ricarda
    Putzer, David
    Dammerer, Dietmar
    Liebensteiner, Michael
    Bach, Christian
    Thaler, Martin
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (05) : 957 - 962
  • [46] Comparison between a two- and a three-dimensional arc plasma configuration
    Freton, P
    Gonzalez, JJ
    Gleizes, A
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2000, 33 (19) : 2442 - 2452
  • [47] Comparison of two- and three-dimensional measurement of the Cobb angle in scoliosis
    Ricarda Lechner
    David Putzer
    Dietmar Dammerer
    Michael Liebensteiner
    Christian Bach
    Martin Thaler
    International Orthopaedics, 2017, 41 : 957 - 962
  • [48] Comparison of two- and three-dimensional reconstruction methods in optical tomography
    Schweiger, M
    Arridge, SR
    APPLIED OPTICS, 1998, 37 (31): : 7419 - 7428
  • [49] Placental and Umbilical Cord Anomalies Diagnosed by Two- and Three-Dimensional Ultrasound
    Santana, Eduardo Felix Martins
    Castello, Renata Gomes
    Rizzo, Giuseppe
    Grisolia, Gianpaolo
    Araujo Junior, Edward
    Werner, Heron
    Lituania, Mario
    Tonni, Gabriele
    DIAGNOSTICS, 2022, 12 (11)
  • [50] Comparison of two- and three-dimensional ultrasonography in the evaluation of fetal heart: Image quality and time spent in the exam
    Guimarães Filho H.A.
    Da Costa L.L.D.
    Araujo Jr. E.
    Zanforlin Filho S.M.
    Pires C.R.
    Nardozza L.M.M.
    Moron A.F.
    Mattar R.