Transthoracic three-dimensional echocardiographic reconstruction of left and right ventricles: In vitro validation and comparison with magnetic resonance imaging

被引:65
|
作者
Pini, R
Giannazzo, G
DiBari, M
Innocenti, F
Rega, L
Casolo, G
Devereux, RB
机构
[1] UNIV FLORENCE, INST GERONTOL & GERIATR, FLORENCE, ITALY
[2] AZIENDA OSPEDALIERA CAREGGI, DEPT RADIOL, FLORENCE, ITALY
[3] NEW YORK HOSP, CORNELL MED CTR, DEPT MED, NEW YORK, NY 10021 USA
关键词
D O I
10.1016/S0002-8703(97)70212-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two-dimensional (2D) echocardiographic and angiographic measurements of ventricular volumes are limited by geometric assumptions concerning cavity shape. We compared in vitro the accuracy of a three-dimensional (3D) echocardiographic system suitable for transthoracic imaging to magnetic resonance imaging (MRI) in the measurement of left and right ventricular volumes. Ventricular cast volumes from 14 excised formalin-fixed sheep hearts filled with an agarose solution were compared with data derived from 3D echocardiography and MRI. Left and right ventricular volumes from 3D echocardiographic reconstructions agreed well with actual volumes without significant underestimation or overestimation. MRI progressively underestimated left ventricular volumes as these increased and systematically underestimated right ventricular volumes. Our echocardiographic system designed for 3D transthoracic imaging combines excellent measurements of left and right ventricular volumes and the computed reconstruction of tomographic slices with the full spatial resolution of the original 2D images. Thus in this in vitro model, 3D echocardiography exhibited greater accuracy than MRI.
引用
收藏
页码:221 / 229
页数:9
相关论文
共 50 条
  • [21] Right Ventricular Volumes Assessed by Echocardiographic Three-dimensional Knowledge-based Reconstruction Compared with Magnetic Resonance Imaging in a Clinical Setting
    Neukamm, Christian
    Try, Kirsti
    Norgard, Gunnar
    Brun, Henrik
    CONGENITAL HEART DISEASE, 2014, 9 (04) : 333 - 342
  • [22] Left ventricular sphericity: comparison of three-dimensional echocardiography and cardiac magnetic resonance imaging
    Patel, A. A.
    Onuora, A. A.
    Toole, R. S.
    Goldman, M.
    Alexander, D.
    Gupta, D.
    Kadiyala, M.
    Cao, J.
    Reichek, N.
    Gopal, A. S.
    EUROPEAN HEART JOURNAL, 2008, 29 : 883 - 883
  • [23] Live three-dimensional right parasternal and supraclavicular transthoracic echocardiographic examination
    Patel, V
    Nanda, NC
    Upendram, S
    Enar, S
    Mehmood, F
    Vengala, S
    Frans, E
    Bodiwala, K
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2005, 22 (04): : 349 - 360
  • [24] Three-dimensional transthoracic echocardiographic visualization of a voluminous left atrial thrombus
    Ieva, R
    Correale, M
    Pellegrino, PL
    Di Biase, M
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (01): : 81 - 82
  • [25] Head-to-Head Comparison of Two-Dimensional and Three-Dimensional Echocardiographic Methods for Left Atrial Chamber Quantification with Magnetic Resonance Imaging
    Buechel, Ronny R.
    Stephan, Frank Peter
    Sommer, Gregor
    Bremerich, Jens
    Zellweger, Michael J.
    Kaufmann, Beat A.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (04) : 428 - 435
  • [26] Three-Dimensional Echocardiographic Assessment of Right Ventricular Volume and Function in Adult Patients With Congenital Heart Disease: Comparison With Magnetic Resonance Imaging
    Grewal, Jasmine
    Majdalany, David
    Syed, Imran
    Pellikka, Patricia
    Warnes, Carole A.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (02) : 127 - 133
  • [27] Three-dimensional echocardiographic measurement of left ventricular wall thickness: In vitro and in vivo validation
    Hubka, M
    Lipiecki, J
    Bolson, EL
    Martin, RW
    Munt, B
    Maza, SR
    Sheehan, FH
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (02) : 129 - 135
  • [28] Three-dimensional echocardiographic reconstruction of the left ventricle by a transesophageal tomographic technique: In vitro and in vivo validation of its volume measurement
    Pai, RG
    Jintapakorn, W
    Tanimoto, M
    Cao, QL
    Pandian, N
    Shah, PM
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (06): : 613 - 621
  • [29] Volumetric analysis of the right and left ventricle in a porcine heart model: Comparison of three-dimensional echocardiography, magnetic resonance imaging and angiocardiography
    Department of Paediatric Cardiology, Heinrich-Heine-Univ., M., Düsseldorf, Germany
    不详
    不详
    Eur. J. Ultrasound, 3 (245-255):
  • [30] Three-dimensional echocardiography: In vitro validation of left and right heart cavity volumes
    Pini, R
    Giannazzo, G
    DiBari, M
    Innocenti, F
    Masotti, L
    Devereux, RB
    ACOUSTICAL IMAGING, VOL 22, 1996, 22 : 263 - 266