Transthoracic three-dimensional echocardiographic reconstruction of left and right ventricles: In vitro validation and comparison with magnetic resonance imaging

被引:65
|
作者
Pini, R
Giannazzo, G
DiBari, M
Innocenti, F
Rega, L
Casolo, G
Devereux, RB
机构
[1] UNIV FLORENCE, INST GERONTOL & GERIATR, FLORENCE, ITALY
[2] AZIENDA OSPEDALIERA CAREGGI, DEPT RADIOL, FLORENCE, ITALY
[3] NEW YORK HOSP, CORNELL MED CTR, DEPT MED, NEW YORK, NY 10021 USA
关键词
D O I
10.1016/S0002-8703(97)70212-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two-dimensional (2D) echocardiographic and angiographic measurements of ventricular volumes are limited by geometric assumptions concerning cavity shape. We compared in vitro the accuracy of a three-dimensional (3D) echocardiographic system suitable for transthoracic imaging to magnetic resonance imaging (MRI) in the measurement of left and right ventricular volumes. Ventricular cast volumes from 14 excised formalin-fixed sheep hearts filled with an agarose solution were compared with data derived from 3D echocardiography and MRI. Left and right ventricular volumes from 3D echocardiographic reconstructions agreed well with actual volumes without significant underestimation or overestimation. MRI progressively underestimated left ventricular volumes as these increased and systematically underestimated right ventricular volumes. Our echocardiographic system designed for 3D transthoracic imaging combines excellent measurements of left and right ventricular volumes and the computed reconstruction of tomographic slices with the full spatial resolution of the original 2D images. Thus in this in vitro model, 3D echocardiography exhibited greater accuracy than MRI.
引用
收藏
页码:221 / 229
页数:9
相关论文
共 50 条
  • [1] Three-dimensional transthoracic echocardiographic measurements of the right ventricular volumes and ejection fraction in human: a validation study with magnetic resonance imaging
    Fujimoto, S
    Mizuno, R
    Dohi, K
    Nakano, H
    CIRCULATION, 1998, 98 (17) : 701 - 701
  • [2] Transthoracic three-dimensional echocardiographic volumetry of distorted left ventricles using rotational scanning
    Kupferwasser, I
    MohrKahaly, S
    Stahr, P
    Rupprecht, HJ
    Nixdorff, U
    Fenster, M
    Voigtlander, T
    Erbel, R
    Meyer, J
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (08) : 840 - 852
  • [3] Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation
    Michal Hubka
    Edward L. Bolson
    John A. McDonald
    Roy W. Martin
    Brad Munt
    Florence H. Sheehan
    The International Journal of Cardiovascular Imaging, 2002, 18 : 111 - 118
  • [4] Three-dimensional echocardiographic measurement of left and right ventricular mass and volume: in vitro validation
    Hubka, M
    Bolson, EL
    McDonald, JA
    Martin, RW
    Munt, B
    Sheehan, FH
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (02): : 111 - 118
  • [5] Comparison of three-dimensional echocardiographic assessment of volume, mass, and function in children with functionally single left ventricles with two-dimensional echocardiography and magnetic resonance imaging
    Altmann, K
    Shen, ZQ
    Boxt, LM
    King, DL
    Gersony, WM
    Allan, LD
    Apfel, HD
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (08): : 1060 - 1065
  • [6] Three-dimensional echocardiographic measurement of left ventricular mass: Comparison with magnetic resonance imaging and two-dimensional echocardiographic determinations in man
    Michael L. Chuang
    Raymond A. Beaudin
    Marilyn F. Riley
    Matthew G. Mooney
    Warren J. Manning
    Pamela S. Douglas
    Mark G. Hibberd
    The International Journal of Cardiac Imaging, 2000, 16 : 347 - 357
  • [7] Three-dimensional echocardiographic measurement of left ventricular mass: Comparison with magnetic resonance imaging and two-dimensional echocardiographic determinations in man
    Chuang, ML
    Beaudin, RA
    Riley, MF
    Mooney, MG
    Manning, WJ
    Douglas, PS
    Hibberd, MG
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (05): : 347 - 357
  • [8] Three-dimensional transthoracic echocardiographic imaging of an unusual congenital left ventricular diverticulum
    Keisuke Kawai
    Hiroshi Watanabe
    Minoru Hasokawa
    Masakazu Nanahoshi
    Hiroshi Yamabe
    Seiichi Kobayashi
    Journal of Echocardiography, 2021, 19 : 63 - 64
  • [9] Three-dimensional transthoracic echocardiographic imaging of an unusual congenital left ventricular diverticulum
    Kawai, Keisuke
    Watanabe, Hiroshi
    Hasokawa, Minoru
    Nanahoshi, Masakazu
    Yamabe, Hiroshi
    Kobayashi, Seiichi
    JOURNAL OF ECHOCARDIOGRAPHY, 2021, 19 (01) : 63 - 64
  • [10] Real-time three-dimensional echocardiographic quantification of left ventricular mass: Comparison with magnetic resonance imaging
    Mor-Avi, V
    Sugeng, L
    Caiani, EG
    Weinert, L
    MacEneaney, P
    Salgo, IS
    Lang, RM
    Computers in Cardiology 2004, Vol 31, 2004, 31 : 65 - 68