A Pilot-Scale Hybrid Adsorption-Biological Treatment System for Nitrogen Removal in Onsite Wastewater Treatment

被引:8
|
作者
Rodriguez-Gonzalez, Laura [1 ]
Miriyala, Amulya [2 ]
Rice, Madison [1 ]
Delgado, Daniel [1 ]
Marshall, Justine [1 ]
Henderson, Michelle [1 ]
Ghebremichael, Kebreab [3 ]
Mihelcic, James R. [1 ]
Ergas, Sarina J. [1 ]
机构
[1] Univ S Florida, Dept Civil & Environm Engn, 4202 E Fowler Ave,ENG 030, Tampa, FL 33620 USA
[2] Grissom Smith Consulting Engineers, 2719 Letap Court,Suite 102, Land Olakes, FL 34638 USA
[3] Univ S Florida, Patel Coll Global Sustainabil, 4202 E Fowler Ave,CGS 238, Tampa, FL 33620 USA
关键词
Biological nitrogen removal; Ion exchange; Recirculating trickling filter; Septic system; Transient loading; AUTOTROPHIC DENITRIFICATION; ION-EXCHANGE; MEDIA;
D O I
10.1061/JSWBAY.0000898
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Onsite wastewater treatment systems (OWTS) are significant nonpoint sources of nutrients to surface and groundwater worldwide. Advanced OWTS are challenged by highly transient nutrient loads, long idle periods (e.g., during vacations), and inadequate maintenance. This study investigated the nitrogen transformation mechanisms and performance of novel two-stage hybrid adsorption and biological treatment systems (HABiTS) that combine biological nitrogen removal and ion exchange to enhance OWTS under transient loading conditions. In the first stage, the natural zeolite mineral, clinoptilolite, which has a high capacity and selectivity for NH4+, was included in a passively aerated nitrifying biofilter. In the second stage, recycled tire mulch, which has a high adsorption capacity for NO3-, was combined with elemental sulfur pellets in a submerged anoxic biofilter for autotrophic sulfur-oxidizing denitrification. Two pilot-scale HABiTS were tested for 434 days, with and without Stage 1 effluent recirculation and predenitrification. Both pilot-scale HABiTS removed >50% of total nitrogen from septic tank effluent. Stage 1 recirculation significantly improved NH4+ removal at both a 1:1 (84%) and a 3:1 (87%) recirculation ratio compared to HABiTS without recirculation (similar to 50%). Recirculation and predenitrification reduced the organic load to the nitrifying biofilter, resulting in increased nitrification and reduced clogging and maintenance requirements. Consistently low effluent NO3- and NO2- concentrations were observed throughout the study in both pilot HABiTS under all conditions applied. The results show that HABiTS is a low-cost, low-energy, and robust process that can consistently achieve advanced secondary OWTS standards under transient loading conditions. (C) 2019 American Society of Civil Engineers.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] WASTEWATER TREATMENT IN A PILOT-SCALE CONSTRUCTED WETLAND
    Akkoyunlu, Atilla
    Bayhan, Hurrem
    Akiner, Muhammed Ernur
    Erturk, Ferruh
    FRESENIUS ENVIRONMENTAL BULLETIN, 2015, 24 (12B): : 4589 - 4596
  • [22] Fate of estrogens in a pilot-scale step-feed anoxic/oxic wastewater treatment system controlling by nitrogen and phosphorus removal
    Chen, Qingcai
    Li, Zebing
    Hua, Xiaoyu
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (13) : 12981 - 12991
  • [23] Bacterial removal in three pilot-scale wastewater treatment systems for rural areas
    Garcia, M
    Becares, E
    WATER SCIENCE AND TECHNOLOGY, 1997, 35 (11-12) : 197 - 200
  • [24] Treatment of Refinery Wastewater with Isolated Biological Aerated Filters: A pilot-scale study
    Huang, Jian-guang
    Zhong, Li
    Xie, Wen-yu
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-4, 2013, 610-613 : 2332 - 2341
  • [25] Feedforward control for nitrogen removal in a pilot-scale anaerobic-anoxic-oxic plant for municipal wastewater treatment
    Shen, Tonggang
    Shi, Hanchang
    Shi, Huiming
    Jing, He
    Xiong, Huilei
    FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING IN CHINA, 2011, 5 (01): : 130 - 139
  • [26] Feedforward control for nitrogen removal in a pilot-scale anaerobic-anoxic-oxic plant for municipal wastewater treatment
    Tonggang Shen
    Hanchang Shi
    Huiming Shi
    He Jing
    Huilei Xiong
    Frontiers of Environmental Science & Engineering in China, 2011, 5 : 130 - 139
  • [27] Ultrasound membrane hybrid processes for dairy wastewater treatment: pilot-scale analysis
    Kertesz, Szabolcs
    Kovacs, Ildiko
    Hodur, Cecilia
    Keszthelyi-Szabo, Gabor
    Vereb, Gabor
    Laszlo, Zsuzsanna
    DESALINATION AND WATER TREATMENT, 2016, 57 (48-49) : 23335 - 23342
  • [28] Enhancing nitrogen removal efficiency in a dyestuff wastewater treatment plant with the IFFAS process: the pilot-scale and full-scale studies
    Mao, Yanjun
    Quan, Xie
    Zhao, Huimin
    Zhang, Yaobin
    Chen, Shuo
    Liu, Tao
    WATER SCIENCE AND TECHNOLOGY, 2018, 77 (01) : 70 - 78
  • [29] Removal of ammonia nitrogen in wastewater by microwave radiation: A pilot-scale study
    Lin, Li
    Chen, Jing
    Xu, Zuqun
    Yuan, Songhu
    Cao, Menghua
    Liu, Huangcheng
    Lu, Xiaohua
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 168 (2-3) : 862 - 867
  • [30] Pilot-scale Study of Biological Synergist Effect on High Salinity Pesticide Wastewater Biological Treatment
    Zou, X. F.
    Ma, F.
    Li, Q. C.
    Ji, H. D.
    Zhuang, H. D.
    Tan, X.
    Wang, J. G.
    Liu, B.
    2018 INTERNATIONAL CONFERENCE OF GREEN BUILDINGS AND ENVIRONMENTAL MANAGEMENT (GBEM 2018), 2018, 186