Solid-phase microextraction of phthalate esters in water sample using different activated carbon-polymer monoliths as adsorbents

被引:45
|
作者
Lirio, Stephen [1 ]
Fu, Chung-Wei [1 ]
Lin, Jhih-Yun [1 ]
Hsu, Meng-Ju [1 ]
Huang, Hsi-Ya [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Chem, 200 Chung Pei Rd, Taoyuan 320, Taiwan
关键词
Phthalate ester; Poly(styrene-divinylbenzene); Activated carbon; Polymer monolith; Solid-phase microextraction; CHROMATOGRAPHY MASS-SPECTROMETRY; PI-PI-INTERACTIONS; GAS-CHROMATOGRAPHY; RIVER WATER; FIBER; EXTRACTION; COLUMNS; OXIDE; CONTAMINATION; ENRICHMENT;
D O I
10.1016/j.aca.2016.05.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the application of different activated carbon-polymer (AC-polymer) monoliths as adsorbents for the solid-phase microextraction (SPME) of phthalate esters (PAEs) in water sample were investigated. The activated carbon (AC) was embedded in organic polymers, poly(butyl methacrylate-co-ethylene dimethacrylate) (poly(BMA-EDMA)) or poly(styrene-co-divinylbenzene) (poly(STY-DVB)), via a 5-min microwave-assisted or a 15-min water bath heating polymerization. Preliminary investigation on the performance of the native poly(BMA-EDMA) and poly(STY-DVB) demonstrated remarkable adsorption efficiencies for PAEs. However, due to the strong hydrophobic, pi-pi, and hydrogen bonding interactions between the analytes and polymers, low extraction recoveries were achieved. In contrast, the presence of AC in native polymers not only enhanced the adsorption efficiencies but also assisted the PAE desorption, especially for AC-poly(STY-DVB) with extraction recovery ranged of 76.2-99.3%. Under the optimized conditions, the extraction recoveries for intra-, inter-day and column-to-column were in the range of 76.5-100.8% (<3.7% RSDs), 77.2-97.6% (<5.6% RSDs) and 75.5-99.7% (<6.2% RSDs), respectively. The developed AC-poly(STY-DVB) monolithic column showed good mechanical stability, which can be reused for more than 30 extraction times without any significant loss in the extraction recoveries of PAEs. The AC-poly(STY-DVB) monolithic column was successfully applied in SPME of PAEs in water sample with extraction recovery ranged of 78.8%-104.6% (<5.5% RSDs). (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 63
页数:9
相关论文
共 50 条
  • [41] Solid-Phase Microextraction of Phthalate Esters from Aqueous Media by Functionalized Carbon Nanotubes (Graphene Oxide Nanoribbons) and Determination by GC-FID
    Kazemi, Maryam
    Niazi, Ali
    Yazdanipour, Atisa
    CHROMATOGRAPHIA, 2021, 84 (06) : 559 - 569
  • [42] DETERMINATION OF TRACE LEACHING PHTHALATE ESTERS IN WATER AND URINE FROM PLASTIC CONTAINERS BY SOLID-PHASE MICROEXTRACTION AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    Lee, Maw-Rong
    Lai, Feng-Ying
    Dou, Jianpeng
    Lin, Keh-Liang
    Chung, Li-Wen
    ANALYTICAL LETTERS, 2011, 44 (04) : 676 - 686
  • [43] Application of solid-phase microextraction to in vitro skin permeation experiments: example using diethyl phthalate
    Frasch, HF
    Barbero, AM
    TOXICOLOGY IN VITRO, 2005, 19 (02) : 253 - 259
  • [44] Graphene-dispersive solid-phase extraction of phthalate acid esters from environmental water
    Wu, Xiaoli
    Hong, Huijie
    Liu, Xiaotong
    Guan, Wenbi
    Meng, Lixuan
    Ye, Yong
    Ma, Yongqiang
    SCIENCE OF THE TOTAL ENVIRONMENT, 2013, 444 : 224 - 230
  • [45] Estimation of measurement uncertainty for the determination of nonylphenol in water using solid-phase extraction and solid-phase microextraction procedures
    Díaz, A
    Vàzquez, L
    Ventura, F
    Galceran, MT
    ANALYTICA CHIMICA ACTA, 2004, 506 (01) : 71 - 80
  • [46] Polymeric ionic liquids as selective coatings for the extraction of esters using solid-phase microextraction
    Zhao, Fei
    Meng, Yunjing
    Anderson, Jared L.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1208 (1-2) : 1 - 9
  • [47] Layered Double Hydroxides as a Coating for the Determination of Phthalate Esters in Aqueous Solution with Solid-Phase Microextraction Followed by Gas Chromatography
    Wang, F. Q.
    Li, J.
    Wu, J. -F.
    Zhao, G-C.
    CHROMATOGRAPHIA, 2018, 81 (05) : 799 - 807
  • [48] Melamine-formaldehyde aerogel functionalized with polydopamine as in-tube solid-phase microextraction coating for the determination of phthalate esters
    Wang, Xiuqin
    Feng, Juanjuan
    Tian, Yu
    Li, Chunying
    Ji, Xiangping
    Luo, Chuannan
    Sun, Min
    TALANTA, 2019, 199 : 317 - 323
  • [49] Layered Double Hydroxides as a Coating for the Determination of Phthalate Esters in Aqueous Solution with Solid-Phase Microextraction Followed by Gas Chromatography
    F. Q. Wang
    J. Li
    J.-F. Wu
    G.-C. Zhao
    Chromatographia, 2018, 81 : 799 - 807
  • [50] In situ growth of covalent organic framework on titanium fiber for headspace solid-phase microextraction of 11 phthalate esters in vegetables
    Yue, Qi
    Huang, Yu-Ying
    Shen, Xiao-Fang
    Yang, Cheng
    Pang, Yue-Hong
    FOOD CHEMISTRY, 2020, 318