A Study on Partial Discharge signals and Noises at On-line Generator Stator Windings

被引:0
|
作者
Hee-Sang, Shin [1 ]
Jae-Chul, Kim [1 ]
机构
[1] Soong Sil Univ, Dept Elect Engn, Seoul, South Korea
来源
T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC | 2009年
关键词
diagnosis; high voltage generator; partial-discharge; stator winding;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Recently, the importance of supplying the reliable electric power is increasing. Insulation deterioration of stator winding is a major cause of faults in high voltage generators. Online partial discharge detection is useful technique to diagnose high voltage generators. Capacitive couplers have been the most widely used for on-line partial discharge detection in high voltage generators. However, interpretation of its result in time domain is very complex because of the mixed results with PD(Partial Discharges) and noises. In this paper, the partial discharge signals and noises were detected using 13[kV] class capacitive couplers at generator stator windings of hydro generators. Characteristics of the partial discharge signals and noises were analyzed. In addition, this paper presents system noise signals caused by sparks from slip rings, power tool operations, transformers and switchgears.
引用
收藏
页码:744 / 747
页数:4
相关论文
共 50 条
  • [21] Experience with continuous Partial Discharge monitoring of stator windings
    Fenger, M
    Stone, GC
    Lloyd, BA
    ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, PROCEEDINGS, 2001, : 417 - 421
  • [22] On-line monitoring of partial discharges on stator windings of large rotating machines in the petrochemical environment
    Bethge, A
    Lo, PKW
    Phillipson, JT
    Weidner, JR
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (06) : 1359 - 1365
  • [23] Identification of stator insulation deterioration using on-line partial discharge testing
    Zhu, H
    Green, V
    Sasic, M
    IEEE ELECTRICAL INSULATION MAGAZINE, 2001, 17 (06) : 21 - 26
  • [24] Study on a spatially selective noise filtration technique for suppressing noises in partial discharge on-line monitoring
    Hu, MY
    Xie, HK
    Tiong, TB
    Wu, XY
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 689 - 692
  • [25] Study of Partial Discharge Ultrasonic Wave Propagation in Generator Stator
    Yang, Yongming
    Duan, Xu
    Jiang, Fan
    MECHATRONICS AND APPLIED MECHANICS, PTS 1 AND 2, 2012, 157-158 : 53 - 57
  • [26] Partial discharge, dissipation factor, and corona aspects for high voltage electric generator stator bars and windings
    Emery, FT
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (02) : 347 - 361
  • [27] Automatic PRPD Image Recognition of Multiple Simultaneous Partial Discharge Sources in On-Line Hydro-Generator Stator Bars
    Araujo, Ramon C. F.
    de Oliveira, Rodrigo M. S.
    Barros, Fabricio J. B.
    ENERGIES, 2022, 15 (01)
  • [28] On-line detection and measurement of partial discharge signals in a noisy environment
    Gaouda, A. M.
    El-Hag, Ayman
    Abdel-Galil, T. K.
    Salama, M. M. A.
    Bartnikas, R.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (04) : 1162 - 1173
  • [29] Analysis of partial discharge to high voltage motor stator windings
    Kim, HD
    2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 340 - 343
  • [30] How humidity affects partial discharge activity in stator windings
    Fenger, M
    Stone, GC
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING TECHNOLOGY CONFERENCE, 2003, : 47 - 50