Out-of-plane strengthening of masonry walls with reinforced composites

被引:89
|
作者
Hamoush, SA [1 ]
McGinley, MW
Mlakar, P
Scott, D
Murray, K
机构
[1] N Carolina Agr & Tech State Univ, Arch Engn Dept, Greensboro, NC 27411 USA
[2] USA, Constr & Mat Div, Waterways Expt Stn, Vicksburg, MS 39180 USA
[3] N Carolina Agr & Tech State Univ, Dept Civil Engn, Greensboro, NC 27411 USA
关键词
D O I
10.1061/(ASCE)1090-0268(2001)5:3(139)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an investigation into the effectiveness of using fiber-reinforced composite overlays to strengthen existing unreinforced masonry walls to resist out-of-plane static loads. A total of fifteen wall panels [1,200 x 1,800 x 200 mm, (4 ft x 6 ft x 8 in.)] were tested. Twelve panels were assembled with fiber-reinforcing systems attached to the tension side, and the remaining three control walls were left without any external reinforcement. Two configurations of external reinforcement were evaluated. The first reinforcement configuration consisted of two layers of fiber-reinforced plastic webbing and the second consisted of vertical and horizontal bands of undirectional fiber composites. The three wall specimens without external reinforcement were tested to evaluate the change in the system strength and behavior with application of the external reinforcing systems. In addition to the two fiber configurations, the testing program also evaluated two methods of surface preparation of the walls, sand blasting, and wire brush. All specimens were thoroughly washed by water jet, 48 hours prior to application of the fiber-reinforcing systems. Three specimens were tested for each variable. A uniformly distributed lateral load was applied to each panel using the procedures described in the ASTM Standard E-72 Test Method (airbag). Failure loads, strains in the external reinforcement (FRP), out-of-plane deformations, and failure modes were recorded. Recommendations on the usefulness of the proposed technique as a means of strengthening masonry walls for out-of-plane loads are presented. In general, flexural strength of masonry walls can be increased if the shear failure is controlled.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 50 条
  • [41] Modelling the out-of-plane behaviour of masonry walls retrofitted with engineered cementitious composites
    Pourfalah, S.
    Cotsovos, D. M.
    Suryanto, B.
    COMPUTERS & STRUCTURES, 2018, 201 : 58 - 79
  • [42] Effectiveness of plasters and textile reinforced mortars for strengthening clay masonry infill walls subjected to combined in-plane/out-of-plane actions
    da Porto, Francesca
    Guidi, Giovanni
    Verlato, Nicolo
    Modena, Claudio
    MAUERWERK, 2015, 19 (05) : 334 - 354
  • [43] Out-of-Plane Strengthening of Masonry Infills Using Textile Reinforced Mortar (TRM) Technique
    Akhoundi, Farhad
    Silva, Luis M.
    Vasconcelos, Graca
    Lourenco, Paulo
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2023, 17 (02) : 310 - 325
  • [44] Short Jute Fiber Reinforced Cement Mortar for Out-of-Plane Strengthening of Masonry Prisms
    Farias, Lidianne do Nascimento
    Lima, Paulo Roberto Lopes
    Toledo, Romildo Dias
    SUSTAINABILITY, 2024, 16 (13)
  • [45] Experimental investigation of the out-of-plane behavior of masonry walls
    Helm, Lukas
    Sadegh-Azar, Hamid
    Schuessler, Jan
    Teutsch, Roman
    MAUERWERK, 2022, 26 (01) : 1 - 10
  • [46] Out-of-Plane Design Procedure for Confined Masonry Walls
    Moreno-Herrera, Joel
    Varela-Rivera, Jorge
    Fernandez-Baqueiro, Luis
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (02)
  • [47] Out-of-plane seismic behaviour of rocking masonry walls
    Al Shawa, Omar
    de Felice, Gianmarco
    Mauro, Alberto
    Sorrentino, Luigi
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (05): : 949 - 968
  • [48] Out-of-plane Proof Testing of Masonry Infill Walls
    Dizhur, Dmytro
    Walsh, Kevin
    Giongo, Ivan
    Derakhshan, Hossein
    Ingham, Jason
    STRUCTURES, 2018, 15 : 244 - 258
  • [49] Shaking table test of fibre reinforced masonry walls under out-of-plane loading
    Nezhad, Razieh Sistani
    Kabir, Mohammad Z.
    Banazadeh, Mehdi
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 120 : 89 - 103
  • [50] Homogenized limit analysis of FRP-reinforced masonry walls out-of-plane loaded
    Gabriele Milani
    Computational Mechanics, 2009, 43 : 617 - 639