SiPM dynamic range for CEPC scintillator-based electromagnetic calorimeter

被引:0
|
作者
Niu, Y. [1 ,2 ,3 ]
Shi, Y. [1 ,2 ,3 ]
Zhao, H. [4 ]
Zhang, Y. [1 ,2 ,3 ]
Ruan, M. [4 ]
Liu, J. [1 ,2 ,3 ]
机构
[1] State Key Lab Particle Detect & Elect, Beijing 100049, Peoples R China
[2] State Key Lab Particle Detect & Elect, Hefei 230026, Peoples R China
[3] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
[4] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2021年 / 16卷 / 12期
基金
中国国家自然科学基金;
关键词
Calorimeter methods; Calorimeters; Scintillators; scintillation and light emission processes (solid; gas and liquid scintillators);
D O I
10.1088/1748-0221/16/12/T12008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-granularity scintillator calorimeter readout with silicon photomultipliers (SiPMs) is an electromagnetic calorimeter (ECAL) candidate for experiments at the Circular Electron Positron Collider (CEPC). A critical design parameter of this ECAL candidate is the dynamic range of the SiPMs. This study investigates the SiPM dynamic range required for the CEPC scintillator ECAL. A model is developed on the basis of the operation principles of SiPMs to describe the response of an SiPM to light pulses within one recovery period by considering the cross-talk effect, photon detection efficiency, and number of pixels. The response curve of a 10000-pixel SiPM predicted by the model is consistent with the measured curve within 2% for an incident light pulse of up to 12000 photons. The intrinsic fluctuations of the SiPM response naturally exist in this model, and the correction of the saturation effect in the SiPM response is investigated. Monte Carlo (MC) simulation shows that the algorithm can restore the response linearity of an SiPM for an incident light pulse in which the number of photons is up to around six times the number of SiPM pixels. The model and correction program are implemented for full simulation of the ZH production Z -> nu nu H -> gamma gamma channel to evaluate the impact of the SiPM dynamic range of the CEPC scintillator ECAL on the reconstructed Higgs boson mass and the sensitivity to the Higgs signal in this channel. The results show that the CEPC scintillator ECAL equipped with no less than 4000 SiPM pixels and operated with a light yield of 20 photon-electrons per channel for a single minimum ionizing particle can meet the requirements for Higgs boson precision measurement in the di-photon channel at the CEPC.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A novel design for a highly granular hadron calorimeter scintillator-SiPM tile
    Garutti, Erika
    Laurien, Sebastian
    Ramilli, Marco
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [22] Current status and development of CMOS SiPM for scintillator-based radiation detectors toward all-digital sensors [Invited]
    'Ascenzo, Nicola
    Hu, Wentao
    Lao, Hui
    Hua, Yuexuan
    Zhang, Bo
    Fang, Lei
    Xi, Daoming
    Zheng, Rui
    Qiu, Ao
    Antonecchia, Emanuele
    Ling, Yiqing
    Liu, Yuqing
    Li, Yan
    Yu, Hang
    Xiao, Peng
    Xie, Qingguo
    CHINESE OPTICS LETTERS, 2024, 22 (02)
  • [23] Plastic scintillator-based dosimeters for FLASH radiotherapy
    Ciarrocchi, E.
    Morrocchi, M.
    Del Sarto, D.
    Di Martino, F.
    Linsalata, S.
    Pensavalle, J. H.
    Bisogni, M. G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S779 - S780
  • [24] SiRO, a scintillator-based hodoscope for muography applications
    Niculescu-Oglinzanu, M.
    Stanca, D.
    Balaceanu, A.
    Dobre, M.
    Gherghel-Lascu, A.
    Saftoiu, A.
    Smau, R.
    Vancea, C.
    JOURNAL OF APPLIED PHYSICS, 2024, 136 (17)
  • [25] Basic Research on Scintillator-based Nuclear Battery
    Yanagida, Takayuki
    Okazaki, Kai
    Miyajima, Keita
    Kato, Takumi
    Nakauchi, Daisuke
    Kawaguchi, Noriaki
    SENSORS AND MATERIALS, 2025, 37 (02) : 453 - 461
  • [26] Liquid Scintillator-Based Neutron Detector Development
    Lavietes, Anthony
    Plenteda, Romano
    Mascarenhas, Nicholas
    Cronholm, L. Marie
    Aspinall, Michael
    Joyce, Malcolm
    Tomanin, Alice
    Peerani, Paolo
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 230 - 244
  • [27] Scintillator-based Photon Counting Detector: is it feasible?
    Blackbcrg, Lisa
    Moebius, Michael
    Moghadam, Narjes
    Uzun-Ozsahin, Dilber
    Mazur, Eric
    El Fakhri, Georges
    Sabet, Hamid
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [28] AN ELECTROMAGNETIC CALORIMETER WITH SCINTILLATOR STRIPS AND WAVELENGTH SHIFTER READOUT
    BARREIRO, F
    LABARGA, L
    LOHR, B
    MATA, J
    DELPESO, J
    ROS, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 257 (02): : 145 - 154
  • [29] Design Studies for a Compact Tungsten Scintillator Electromagnetic Calorimeter
    Woody, C.
    Cheung, S.
    Haggerty, J.
    Kistenev, E.
    Stol, S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1471 - 1475
  • [30] Development of double SiPM readout method for ILD scintillator electro-magnetic calorimeter
    Masuda, R.
    Ootani, W.
    Tsuji, N.
    Liu, L.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (06):