Periodontal-masseteric reflexes decrease with tooth pre-load

被引:3
|
作者
Sowman, P. F. [1 ]
Tuerker, K. S. [1 ,2 ,3 ]
机构
[1] Univ Adelaide, Sch Mol & Biomed Sci, Discipline Physiol, Res Ctr Human Movement Control, Adelaide, SA 5005, Australia
[2] Ege Univ, Dept Physiol, Fac Med, TR-35100 Izmir, Turkey
[3] Ege Univ, Ctr Brain Res, TR-35100 Izmir, Turkey
关键词
periodontal mechanoreceptors; masseter; reflex; saturation;
D O I
10.1177/154405910808700213
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The responses of incisal periodontal mechanoreceptors to increasing mechanical stimulation are known to follow a hyperbolic-saturating course. The implications of these properties for the reflexive control of bite-force have not been examined directly. In line with the abovementioned receptor characteristics, we hypothesized that the periodontal-masseteric reflex will reduce as a function of increasing incisal pre-load. In 10 participants, a central incisor was repeatedly tapped (0.4 N). We measured the modulation by pre-load (0.2-2.0 N) of the reflex frequency-response at and between 3 and 20 Hz. The entrainment of the reflex increased with frequency up to 20 Hz and diminished with increasing pre-load. Importantly, the hyperbolic relationship shown here between the periodontal-masseteric reflex and tooth pre-load agreed with the load/response relationships predicted by single-receptor and tooth movement studies. This study demonstrated that periodontal mechanoreceptors are able to contribute to the ongoing control of only small bite-forces.
引用
收藏
页码:175 / 179
页数:5
相关论文
共 50 条
  • [31] PERMEABILITY OF SFRCC BASED ON FINE AGGREGATE AFTER PRE-LOAD CYCLES
    Katzer, Jacek
    BRITTLE MATRIX COMPOSITES 9, 2009, : 139 - 148
  • [32] Effects of Antagonist Pre-load on Agonist Muscle Performance in Young Men
    Carregaro, Rodrigo
    Gentil, Paulo
    Brown, Lee E.
    Bottaro, Martim
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 295 - 295
  • [33] Dynamic Response of the Pre-load Steel Frame Under Transverse Impact
    Yang, Mianyue
    Fu, Chaojiang
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON APPLIED MATHEMATICS, MODELING AND SIMULATION (AMMS 2017), 2017, 153 : 361 - 364
  • [34] The effect of coefficient of friction on pre-load with a given tightening torque.
    Lang, L. A.
    Kang, B.
    Wang, R. -F.
    Lang, B. R.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B141 - B141
  • [35] The effect of pre-load and associated deformation on the stability of a simple updating problem
    Greening, PD
    Lieven, NAJ
    PROCEEDINGS OF THE 15TH INTERNATIONAL MODAL ANALYSIS CONFERENCE - IMAC, VOLS I AND II, 1997, 3089 : 1188 - 1194
  • [36] Influence of a defined pre-load on the stress state in the precision cutting process
    Neugebauer, Reimund
    Kraeusel, Verena
    Barthel, Tom
    Jesche, Fred
    Schoenherr, Julia
    CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2013, 62 (01) : 271 - 274
  • [37] Loss of pre-load in gold prosthesis-retaining implant screws.
    Cantwell, A
    Hobkirk, JA
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 212 - 212
  • [38] Mechanical analysis of the European DEMO central solenoid pre-load structure and coils
    Nunio, Francois
    Torre, Alexandre
    Zani, Louis
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 168 - 172
  • [39] EFFECT OF PRE-LOAD AND ACTIVE TENSION ON VASCULAR RESPONSES IN-VITRO
    BURNS, TD
    REINKE, DA
    CHOU, CC
    DABNEY, JM
    PHARMACOLOGIST, 1971, 13 (02): : 250 - &
  • [40] SELECTIVE REDUCTION OF PRE-LOAD IMPROVES VENTRICULAR DIASTOLIC FUNCTION IN HYPERTENSION
    Faconti, L.
    Farukh, B.
    Brett, S.
    Chowienczyk, P.
    JOURNAL OF HYPERTENSION, 2017, 35 : E288 - E288