Simultaneous quantification of sulfamethoxazole and trimethoprim in whole egg samples by column-switching high-performance liquid chromatography using restricted access media column for on-line sample clean-up

被引:59
|
作者
de Paula, F. C. C. R. [1 ]
de Pietro, A. C. [1 ]
Cass, Q. B. [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
restricted access media (RAM); column-switching; sulfamethoxazole; trimethoprim; eggs;
D O I
10.1016/j.chroma.2007.08.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work reports the application of restricted access media (RAM) column, in a multidimensional configuration, for simultaneous analysis of sulfamethoxazole (SMX) and trimethoprim (TMP) in whole eggs with ultraviolet detection. The proteins were partially precipitated by adding 0.5 mL of acetonitrile into 1.0 mL of blended egg followed by centrifugation. The supernatant was injected (250 mu L) directly into the muldimensional system. At the first dimension, a restricted access medium (RAM) bovine serum albumin (BSA) octadecyl column (100 mm x 46 mm I.D., Luna (R) silica, 10 mu m particle size and 100 angstrom pore size), was used for extraction and concentration of the analytes and at second dimension, an octadecyl column (150 mm x 46 mm I.D., Luna (R) silica, 10 mu m particle size and 100 angstrom pore size), for analysis. The developed method showed good selectivity, accuracy and precision for quantification of these different compounds in eggs, and the limits of quantification were 80 ng/mL, for both compounds. The validated method is reliable and sensitive for monitoring residues in whole eggs samples and thus, to determine withdraw period for laying hens using veterinary medicine having SMX-TMP combination. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 50 条
  • [21] Simple and simultaneous determination of sulphapyridine and acetylsulphapyridine in human serum by column-switching high-performance liquid chromatography
    Teshima, D
    Hino, B
    Itoh, Y
    Oishi, R
    JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 2002, 27 (06) : 403 - 408
  • [22] Simultaneous determination of baicalin, rhein and berberine in rat plasma by column-switching high-performance liquid chromatography
    Li Yi
    Gao Jian-Ping
    Xu Xu
    Dai Lixin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 838 (01): : 50 - 55
  • [23] Study of salivary catecholamines using fully automated column-switching high-performance liquid chromatography
    Okumura, T
    Nakajima, Y
    Matsuoka, M
    Takamatsu, T
    JOURNAL OF CHROMATOGRAPHY B, 1997, 694 (02): : 305 - 316
  • [24] Method for determining monohydroxybenzo[a]pyrene isomers using column-switching high-performance liquid chromatography
    Toriba, A
    Nakamura, H
    Chetiyanukornkul, T
    Kizu, R
    Makino, T
    Nakazawa, H
    Yokoi, T
    Hayakawa, K
    ANALYTICAL BIOCHEMISTRY, 2003, 312 (01) : 14 - 22
  • [25] SIMULTANEOUS DETERMINATION OF AMPICILLIN AND METAMPICILLIN IN BIOLOGICAL-FLUIDS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    LEE, HY
    LEE, JS
    LEE, HS
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 664 (02): : 335 - 340
  • [26] A simple quantitative assay for urinary adenosine using column-switching high-performance liquid chromatography
    Taniai, H
    Sumi, S
    Ito, T
    Ueta, A
    Ohkubo, Y
    Togari, H
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2006, 208 (01): : 57 - 63
  • [27] Rapid method for the determination of ochratoxin A in urine by immunoaffinity column clean-up and high-performance liquid chromatography
    Michelangelo Pascale
    Angelo Visconti
    Mycopathologia, 2001, 152 : 91 - 95
  • [28] Rapid method for the determination of ochratoxin A in urine by immunoaffinity column clean-up and high-performance liquid chromatography
    Pascale, M
    Visconti, A
    MYCOPATHOLOGIA, 2001, 152 (02) : 91 - 95
  • [29] Determination of myristicin in rat serum samples using microbore high performance liquid chromatography with column-switching
    H. S. Lee
    J. H. Kim
    K. Kim
    K. S. Do
    Chromatographia, 1998, 48 : 365 - 368
  • [30] Determination of myristicin in rat serum samples using microbore high performance liquid chromatography with column-switching
    Lee, HS
    Kim, JH
    Kim, K
    Do, KS
    CHROMATOGRAPHIA, 1998, 48 (5-6) : 365 - 368