Fabrication of Zirconia Abutment Crown and Clasp Under Existing Removable Partial Denture Using CAD/CAM Technology

被引:3
|
作者
Tasaka, Akinori [1 ]
Shimizu, Takahiro [1 ]
Hirabayashi, Takeshi [2 ]
Yamashita, Shuichiro [1 ]
机构
[1] Tokyo Dent Coll, Dept Removable Partial Prosthodont, Tokyo, Japan
[2] Tokyo Dent Coll, Dent Lab Suidobashi Hosp, Tokyo, Japan
来源
CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY | 2021年 / 13卷
关键词
removable partial denture; denture repair; CAD/CAM; zirconia crown; I bar clasp; DENTAL PROSTHESIS; CERAMIC CROWN; REPLACEMENT;
D O I
10.2147/CCIDE.S332944
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This clinical report describes a technique for fabricating a retrofit zirconia crown and clasp for an existing removable partial denture (RPD) using computer-aided design and computer-aided manufacturing (CAD/CAM). A 58-year-old patient developed acute pulpitis of a tooth, and the RPD clasp was broken on the tooth. A pre-preparation scan was captured using an intraoral scanner. The existing RPD was placed in the mouth, and scans of the post-preparation, antagonist arch, and interocclusal record were made. A zirconia crown was designed by superimposing the pre-preparation scan and the post-preparation scan of the abutment tooth. The design data were transferred to a 5-axis milling machine, and the crown was milled from zirconia. The crown was luted using resin cement. An intraoral scan of the crown with RPD was taken, and the RPD was removed to re-scan the proximal guide plane of the crown. The I-bar clasp was designed, and the casting pattern was built using a 3D printer. The pattern was used to cast the clasp. The clasp was set using autopolymerizing acrylic resin to the RPD. The main advantages of this efficient process are that patients can use their RPDs during fabrication of the crown of the abutment tooth. The limitations of using this technique include the cost of the intraoral scanner and the education for the dental clinicians and technicians. In this clinical report, CAD/CAM technology prevented human error, required no adjustment, and uninterrupted use of the RPD for fabricating a retrofit zirconia crown and clasp for an existing RPD.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 50 条
  • [41] An In Vitro Investigation of Accuracy and Fit of Conventional and CAD/CAM Removable Partial Denture Frameworks
    Soltanzadeh, Pooya
    Suprono, Montry S.
    Kattadiyil, Mathew T.
    Goodacre, Charles
    Gregorius, Wendy
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (05): : 547 - 555
  • [42] AN INDIRECT PROCEDURE FOR MAKING A CROWN UNDER AN EXISTING PARTIAL DENTURE
    SILBERMAN, DM
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (06): : 631 - 633
  • [43] Use of an open-source CAD software program and additive manufacturing technology to design and fabricate a definitive cast for retrofitting a crown to an existing removable partial denture
    Su, Fang-Yu
    Tsai, Jen-Chih
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (04): : 351 - 354
  • [44] Fabrication of an accurate guide plane template for removable partial dentures by using CAD-CAM
    Liu, Xiaozhou
    Jiang, Xiaotong
    Xiao, Jiwei
    Wu, Lin
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1025 - 1028
  • [45] Titanium removable partial denture clasp repair using laser welding: A clinical report
    Suzuki, Y
    Ohkubo, C
    Abe, M
    Hosoi, T
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (05): : 418 - 420
  • [46] Biomechanical behaviour of tilted abutment after fixed partial denture restoration of CAD/CAM materials
    Zhu, Tong
    Chen, Jingyi
    Xu, Yichen
    Zhu, Zhou
    Wang, Jian
    Pei, Xibo
    Qiao, Mingxin
    Cheng, Bin
    Li, Ruyi
    Wan, Qianbing
    BMC ORAL HEALTH, 2024, 24 (01):
  • [47] An indirect-direct technique with hot water for fabricating a cast metal crown under an existing removable partial denture
    Haraguchi, Mihoko
    Towithelertkul, Cheewin
    Ali, Islam E.
    Han, Xuewei
    Sumita, Yuka I.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (02): : 320 - 325
  • [48] The Use of CAD/CAM Technology for Fabricating Cast Gold Survey Crowns under Existing Partial Removable Dental Prosthesis. A Clinical Report
    El Kerdani, Tarek
    Roushdy, Sally
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (04): : 321 - 326
  • [49] REACTION OF THE ANTERIOR ABUTMENT OF A KENNEDY CLASS-II REMOVABLE PARTIAL DENTURE TO VARIOUS CLASP ARM DESIGNS - AN INVITRO STUDY
    FIRTELL, DN
    GRISIUS, RJ
    MUNCHERYAN, AM
    JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (01): : 77 - 82
  • [50] A combined analog and digital workflow for retrofitting a monolithic ceramic crown to an existing removable partial denture
    Hosney, Sherif
    Carranza, Maria Gabriela
    Geminiani, Alessandro
    Ercoli, Carlo
    Papaspyridakos, Panos
    Chochlidakis, Konstantinos
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (04): : 585 - 587