Numerical assessment on the thermal imbalance of multiple ground heat exchangers connected in parallel

被引:13
|
作者
Chen, Fei [1 ]
Mao, Jinfeng [2 ]
Zhu, Guodong [1 ]
Zhang, Bing [1 ]
Tian, Yongjie [1 ]
Liao, Dan [1 ]
Liu, Ying [1 ]
机构
[1] Beijing Special Engn Design & Res Inst, Beijing 100028, Peoples R China
[2] Arrny Engn Univ PLA, Coll Def Engn, Nanjing 210007, Peoples R China
关键词
Multiple ground heat exchangers; Boundary conditions; Thermal imbalance; Load ratios; Borehole field layouts and scales; FINITE-ELEMENT FORMULATION; OPERATION; PERFORMANCE; SIMULATION; EFFICIENCY; BOREHOLES; SYSTEMS; STORAGE; MODEL;
D O I
10.1016/j.geothermics.2021.102191
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermal imbalance is a common problem in ground source heat pump (GSHP) systems, especially those with large scale multiple ground heat exchangers (GHEs). It usually happens due to the imbalance between the accumulated heat extracted from and injected into the soil and can lead to heat or cold accumulation, cooling or heating performance deterioration and even system failure. In most projects, the GHEs are not independent of each other, but are connected in parallel as an entirety. Therefore, the interconnections among each GHE within the borehole field should be considered. In this study, a numerical approach considering models of the heat pump and the water separator/collector was established for the thermal imbalance evaluation of multiple GHEs connected in parallel, and it was validated by an in-situ test of a single GHE. The necessity of introducing such models was discussed, and the effects of load ratios, borehole layouts, and scales were also investigated. Results show that when both the heat pump and the water separator/collector were considered, the temperature distribution of the borehole field was always uniform during the five-year operation with the highest temperature unevenness value of 0.37 degrees C, proving that the self-adjusting mechanism of the GHE load (i.e., the GHE load distribution of the borehole field is able to be optimized automatically according to the heat transfer condition of each GHE) is beneficial to maintaining the thermal balance of the borehole field. However, when the interconnections among the GHEs are ignored, the thermal imbalance of the borehole field is overestimated, in particular, under conditions with large load ratios. With the increase in the field scale, the temperature unevenness value of the borehole field first increases and then decreases whether in square or regular hexagon layouts. The numerical approach in this study is helpful to correctly evaluate the thermal imbalance of the borehole field.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Numerical Simulations of a Ground Source Heat Pump System With Pile Heat Exchangers
    Oguma, Masahito
    Matsumoto, Takeshi
    Kakizaki, Takao
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2015, 7 (01)
  • [32] Zoning operation of multiple borehole ground heat exchangers to alleviate the ground thermal accumulation caused by unbalanced seasonal loads
    Yu Mingzhi
    Zhang Kai
    Cao Xizhong
    Hu Aijuan
    Cui Ping
    Fang Zhaohong
    ENERGY AND BUILDINGS, 2016, 110 : 345 - 352
  • [33] Simulation Tool for Ground-Source Heat Pump System with Multiple Ground Heat Exchangers
    Katsura, Tako
    Nagano, Katsunori
    ASHRAE TRANSACTIONS 2018, VOL 124, PT 2, 2018, 124 : 92 - 101
  • [34] A numerical study on heat transfer performances of horizontal ground heat exchangers in ground-source heat pumps
    Zou, Hang
    Pei, Peng
    Wang, Chen
    Hao, Dingyi
    PLOS ONE, 2021, 16 (05):
  • [35] Long-term thermal imbalance in large borehole heat exchangers array - A numerical study based on the Leicester project
    Chen, Shuang
    Cai, Wanlong
    Witte, Francesco
    Wang, Xuerui
    Wang, Fenghao
    Kolditz, Olaf
    Shao, Haibing
    ENERGY AND BUILDINGS, 2021, 231
  • [36] The influence of natural convection on thermal performance of ground heat exchangers
    Bidarmaghz, A.
    Narsilio, G. A.
    ENERGY GEOTECHNICS, 2016, : 145 - 148
  • [37] Factors Influencing the Thermal Efficiency of Horizontal Ground Heat Exchangers
    Di Sipio, Eloisa
    Bertermann, David
    ENERGIES, 2017, 10 (11):
  • [38] THERMAL PERFORMANCES OF VERTICAL GROUND HEAT EXCHANGERS IN DIFFERENT CONDITIONS
    Jalaluddin
    Miyara, Akio
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2016, 11 (12) : 1771 - 1783
  • [39] Parallel-flow heat exchangers with ambient thermal interaction
    Ameel, TA
    HEAT TRANSFER ENGINEERING, 2000, 21 (06) : 18 - 25
  • [40] Models of thermal response tests on deep coaxial borehole heat exchangers through multiple ground layers
    Beier, Richard A.
    Fossa, Marco
    Morchio, Stefano
    APPLIED THERMAL ENGINEERING, 2021, 184