Performances of a newly high sensitive trilaver F/CU/F GMI sensor

被引:0
|
作者
Alves, F. [1 ,2 ,3 ,4 ,5 ]
Kaviraj, B. [1 ,2 ,3 ,4 ,5 ]
Rached, L. Abi [1 ,2 ,3 ,4 ,5 ]
Moutoussamy, J. [6 ]
Coillot, C. [6 ]
机构
[1] LGEP SPEE Labs, F-91192 Gif Sur Yvette, France
[2] CNRS, UMR 8507, F-91192 Gif Sur Yvette, France
[3] Supelec, F-91192 Gif Sur Yvette, France
[4] Univ Paris 06, F-91192 Gif Sur Yvette, France
[5] Univ Paris Sud P11, F-91192 Gif Sur Yvette, France
[6] CNRS, IPSL, CETP, UMR 8639, F-78140 Velizy Villacoublay, France
来源
TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2 | 2007年
关键词
magneto-impedance; stress-annealing; nanocrystalline materials; sensors;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have selected stress-annealed nanocrystalline Fe-based ribbons for magnetic/copper/magnetic sensors exhibiting high magneto-impedance ratio. Longitudinal magneto-impedance Delta Z/Z(sat) reaches 400% at 60 kHz and longitudinal magneto-resistance Delta R/R-sat increases up to 1100% around 300 kHz.
引用
收藏
页数:2
相关论文
共 50 条
  • [41] Cu(II)-Mediated direct 18F-dehydrofluorination of phosphine oxides in high molar activity
    Xiaoqun Tang
    Shengji Lv
    Zhaobiao Mou
    Xia Liu
    Zijing Li
    EJNMMI Radiopharmacy and Chemistry, 9
  • [42] Prognostic Significance of Dynamic 18F-FET PET in Newly Diagnosed Astrocytic High-Grade Glioma
    Jansen, Nathalie L.
    Suchorska, Bogdana
    Wenter, Vera
    Schmid-Tannwald, Christine
    Todica, Andrei
    Eigenbrod, Sabina
    Niyazi, Maximilian
    Tonn, Joerg-Christian
    Bartenstein, Peter
    Kreth, Friedrich-Wilhelm
    la Fougere, Christian
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 9 - 15
  • [43] High performances of 18F-fluorodeoxyglucose PET-CT in cardiac implantable device infections: A study of 40 patients
    Tlili, Ghoufrane
    Amroui, Sana
    Mesguich, Charles
    Riviere, Annalisa
    Bordachar, Pierre
    Hindie, Elif
    Bordenave, Laurence
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (04) : 787 - 798
  • [44] High performances of 18F-fluorodeoxyglucose PET-CT in cardiac implantable device infections: A study of 40 patients
    Ghoufrane Tlili
    Sana Amroui
    Charles Mesguich
    Annalisa Rivière
    Pierre Bordachar
    Elif Hindié
    Laurence Bordenave
    Journal of Nuclear Cardiology, 2015, 22 : 787 - 798
  • [45] The effect of photoperiod and high fat diet on the cognitive response in photoperiod-sensitive F344 rats
    McLean, Samantha L.
    Yun, Haesung
    Tedder, Andrew
    Helfer, Gisela
    PHYSIOLOGY & BEHAVIOR, 2021, 239
  • [46] Dual-channel detection of Cu2+ and F- with a simple Schiff-based colorimetric and fluorescent sensor
    Na, Yu Jeong
    Choi, Ye Won
    Yun, Jin Yeong
    Park, Kyung-Min
    Chang, Pahn-Shick
    Kim, Cheal
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 136 : 1649 - 1657
  • [47] A Fluoro-Chromogenic Sensor Based on Organic Molecular Framework for Cu2+ and F- in Aqueous Soluble DMSO
    Uahengo, Veikko
    Zhang, Yan
    Xiong, Bi
    Zhao, Pingping
    Cai, Ping
    Rhyman, Lydia
    Ramasami, Ponnadurai
    Hu, Kai
    Cheng, Gongzhen
    JOURNAL OF FLUORESCENCE, 2017, 27 (01) : 191 - 197
  • [48] FeS2@f-CNF Nanocomposite-Based electrochemical sensor for Ultra-Sensitive detection of biomarker Vanillylmandelic acid
    Gopika, M. G.
    Yusuf, Kareem
    Kuo, Chih-Yu
    Saraswathyamma, Beena
    Govindasamy, Mani
    MICROCHEMICAL JOURNAL, 2025, 212
  • [49] Evaluation of a new calix[4]arene based molecular receptor for sensitive and selective recognition of F- and Cu2+ ions
    Chawla, Har Mohindra
    Gupta, Tanu
    JOURNAL OF LUMINESCENCE, 2014, 154 : 89 - 94
  • [50] HIGH CONDUCTIVITY A-SI-H-F FILM AND ITS PERFORMANCE FOR A POWER SENSOR AND A STRAIN-GAUGE
    KODATO, S
    NISHIDA, S
    KONAGAI, M
    TAKAHASHI, K
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1983, 59-6 (DEC) : 1207 - 1210