Reduced Field-of-View Diffusion Imaging of the Human Spinal Cord: Comparison with Conventional Single-Shot Echo-Planar Imaging

被引:87
|
作者
Zaharchuk, G. [1 ]
Saritas, E. U. [2 ]
Andre, J. B.
Chin, C. T. [3 ]
Rosenberg, J.
Brosnan, T. J.
Shankaranarayan, A. [4 ]
Nishimura, D. G. [2 ]
Fischbein, N. J.
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA USA
[4] GE Healthcare, Appl Sci Lab W, Menlo Pk, CA USA
关键词
WEIGHTED MRI; MULTIPLE-SCLEROSIS; IN-VIVO; CERVICAL CORD; OPTIC-NERVE; TENSOR MRI; RESOLUTION; INFARCTION; EPI; TRACTOGRAPHY;
D O I
10.3174/ajnr.A2418
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI of the spinal cord is challenging because of its small size and artifacts associated with the most commonly used clinical imaging method, SS-EPI. We evaluated the performance of rFOV spinal cord DWI and compared it with the routine fF0V SS-EPI in a clinical population. MATERIALS AND METHODS: Thirty-six clinical patients underwent 1.5T MR imaging examination that included rFOV SS-EPI DWI of the cervical spinal cord as well as 2 comparison diffusion sequences: fF0V SS-EPI DWI normalized for either image readout time (low-resolution fF0V) or spatial resolution (high-resolution fF0V). ADC maps were created and compared between the methods by using single-factor analysis of variance. Two neuroradiologists blinded to sequence type rated the 3 DWI methods, based on susceptibility artifacts, perceived spatial resolution, signal intensity-to-noise ratio, anatomic detail, and clinical utility. RESULTS: ADC values for the rFOV and both fF0V sequences were not statistically different (rFOV: 1.01 +/- 0.18 x 10(-3) mm(2)/s; low-resolution fFOV: 1.12 +/- 0.22 X 10(-3) mm(2)/s; high-resolution fFOV: 1.10 +/- 0.21 x 10(-3) mm(2)/s; F = 2.747, P > .05). The neuroradiologist reviewers rated the rFOV diffusion images superior in terms of all assessed measures (P < 0.0001). Particular improvements were noted in patients with metal hardware, degenerative disease, or both. CONCLUSIONS: rFOV DWI of the spinal cord overcomes many of the problems associated with conventional fF0V SS-EPI and is feasible in a clinical population. From a clinical standpoint, images were deemed superior to those created by using standard fF0V methods.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [31] Analysis of Apparent Diffusion Coefficients of the Brain in Healthy Controls: A Comparison Study between Single-Shot Echo-Planar Imaging and Read-out-Segmented Echo-Planar Imaging
    Choi, Yangsean
    Hwang, Eo-Jin
    Nam, Yoonho
    Choi, Hyun Seok
    Jang, Jinhee
    Jung, So-Lyung
    Ahn, Kook-Jin
    Kim, Bum-soo
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (07) : 1138 - 1145
  • [32] CARDIAC ECHO-PLANAR MR-IMAGING - COMPARISON OF SINGLE-SHOT AND MULTIPLE-SHOT TECHNIQUES
    WETTER, DR
    MCKINNON, GC
    DEBATIN, JF
    VONSCHULTHESS, GK
    RADIOLOGY, 1995, 194 (03) : 765 - 770
  • [33] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    He An
    Xiaodong Ma
    Ziyi Pan
    Hua Guo
    Elaine Yuen Phin Lee
    European Radiology, 2020, 30 : 1876 - 1884
  • [34] Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time
    Wolansky, LJ
    Chong, S
    Liu, WC
    Kang, E
    Simpson, SW
    Karimi, S
    Akbari, H
    NEURORADIOLOGY, 1999, 41 (03) : 163 - 166
  • [35] Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time
    L. J. Wolansky
    S. Chong
    W. C. Liu
    E. Kang
    S. W. Simpson
    S. Karimi
    H. Akbari
    Neuroradiology, 1999, 41 : 163 - 166
  • [36] Clinical evaluation of single-shot signa-horizon echo-planar imaging: Comparison with fast SE imaging
    Krol, GS
    OMalley, BB
    Donovan, WD
    Pisinski, L
    RADIOLOGY, 1996, 201 : 984 - 984
  • [37] Evaluation of Thin-slice Coronal Single-shot Turbo Spin-echo Diffusion-weighted Imaging of the Hand: A Comparison with Conventional Echo-planar Diffusion-weighted Imaging
    Ogawa, Masaki
    Nakagawa, Motoo
    Arai, Nobuyuki
    Kan, Hirohito
    Ohba, Shota
    Shibata, Shunsuke
    Maki, Hiroyuki
    Shibamoto, Yuta
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (04) : 382 - 388
  • [38] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [39] Histogram analysis of breast diffusion kurtosis imaging: a comparison between readout-segmented and single-shot echo-planar imaging sequence
    Huang, Cicheng
    Zhan, Chenao
    Hu, Yiqi
    Yin, Ting
    Grimm, Robert
    Ai, Tao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022,
  • [40] Ultrahigh Resolution Reduced Field-Of-View Diffusion Tensor Imaging in the Spinal Cord
    Gaggl, W.
    Reuss, J.
    Field, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 141 - 141