Structural performance and cost analysis of wind-induced vibration control schemes for a real super-tall building

被引:30
|
作者
Wang, Dayang [1 ]
Tse, Tim K. T. [2 ]
Zhou, Yun [1 ]
Li, Qingxiang [3 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
[3] Guangdong Prov Acad Bldg Res, Guangzhou 510500, Guangdong, Peoples R China
关键词
cost evaluation; tuned mass dampers; wind-induced vibrations; viscous dampers; super-tall buildings; TUNED MASS DAMPERS; OPTIMAL-DESIGN THEORIES; MOTION;
D O I
10.1080/15732479.2014.925941
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To evaluate different energy dissipation systems used to control wind-induced vibrations of a 456m super-tall building in fluctuating wind excitations, the finite element (FE) method was employed to simulate the dynamic responses of the building. A series of wind tunnel pressure tests were conducted on a 1:450 scale model to determine the wind forces acting on the super-tall building. A FE model was also constructed and mass, damping and stiffness matrices were subsequently formulated as an evaluation model for numerical analysis. The evaluation model was further simplified to a state reduced-order system using the state order reduction method. Three different vibration control schemes, namely a tuned mass damper (TMD) system, a system containing only nonlinear viscous dampers and a hybrid control system combining TMD and viscous dampers, were examined through simulations with respect to their effectiveness in reducing the accelerations at the top of the building. Furthermore, a cost evaluation was conducted to determine the most economical structural design and vibration control scheme. The results show that the wind-induced vibrations of the analysed building can be controlled effectively by all the three examined schemes, while the hybrid control scheme and the scheme containing only viscous dampers further reduce the wind-induced vibration to satisfy a more stringent criterion for a six-star hotel. In addition, the hybrid vibration control scheme is also the most cost-effective among the examined schemes.
引用
收藏
页码:990 / 1011
页数:22
相关论文
共 50 条
  • [21] Evaluation of wind loads and wind induced responses of a super-tall building by large eddy simulation
    Lu, C. L.
    Huang, S. H.
    Tuan, Alex Y.
    Zhi, L. H.
    Su, Sheng-chung
    WIND AND STRUCTURES, 2016, 23 (04) : 313 - 350
  • [22] Evaluation of wind loads on super-tall buildings from field-measured wind-induced acceleration response
    Xu, A.
    Xie, Z. N.
    Fu, J. Y.
    Wu, J. R.
    Tuan, Alex
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2014, 23 (09): : 641 - 663
  • [23] Effects of wind-induced tall building motion on cognitive performance
    Denoon, Roy O.
    Roberts, Richard D.
    Letchford, Christopher W.
    Kwok, Kenny C.S.
    Research Report - University of Sydney, Department of Civil Engineering, 2000, (804): : 1 - 69
  • [24] WIND LOAD SIMULATION AND WIND-INDUCED VIBRATION TIME-HISTORY ANALYSIS OF TALL BUILDING STRUCTURES
    Mao, Gui-Niu
    Han, Xiao-Lei
    Chen, Xue-Wei
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 1526 - 1531
  • [25] Design of Tuned Mass Damper Fluid Inerter for Wind-Induced Vibration Control of a Tall Building
    Sarkar, Saptarshi
    Fitzgerald, Breiffni
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (03)
  • [26] Analysis on Wind-induced Vibration of Tall Buildings in Hilly Terrain
    Sun, Yi
    Deng, Nuan
    Li, Zhengliang
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 2567 - +
  • [27] A combined tuned damper and an optimal design method for wind-induced vibration control for super tall buildings
    Wang, Lilin
    Zhao, Xin
    Zheng, Yimin M.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2016, 25 (10): : 468 - 502
  • [28] Analysis and design method for wind-induced vibration passive damping control of tall buildings
    Ou, Jinping
    Zhang, Weijing
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2003, 24 (06):
  • [29] SUPPRESSION OF WIND-INDUCED VIBRATION OF A TALL BUILDING USING TUNED LIQUID DAMPER
    WAKAHARA, T
    OHYAMA, T
    FUJII, K
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 43 (1-3) : 1895 - 1906
  • [30] Use of TLD and MTLD for control of wind-induced vibration of tall buildings
    Kim, Young-Moon
    You, Ki-Pyo
    Ko, Nag-Ho
    Yoon, Sung-Won
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2006, 20 (09) : 1346 - 1354