Determination of antihypertensive and anti-ulcer agents from surface water with solid-phase extraction-liquid chromatography-electrospray ionization tandem mass spectrometry

被引:32
|
作者
Varga, Renata [1 ]
Somogyvari, Ivan [1 ]
Eke, Zsuzsanna [1 ]
Torkos, Kornel [1 ]
机构
[1] Eotvos Lorand Univ, Joint Res & Training Lab Separat Tech, H-1117 Budapest, Hungary
关键词
Anti-ulcer agents; Antihypertensive drugs; Water analysis; Liquid chromatography-tandem mass spectrometry; Solid-phase extraction; Post-extraction spike method; SEWAGE-TREATMENT PLANTS; 9 BASIC PHARMACEUTICALS; RAY CONTRAST-MEDIA; ENVIRONMENTAL-SAMPLES; WASTE-WATER; AQUEOUS SAMPLES; ANALYTICAL METHODOLOGIES; LC/MS/MS ANALYSES; ION SUPPRESSION; ILLICIT DRUGS;
D O I
10.1016/j.talanta.2010.11.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pharmaceuticals are emerging contaminants in surface water and they must be measured to follow their effects on the aquatic environment. We developed a solid-phase extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (SPE-LC-ESI-MS/MS) method for the determination of twenty-six pharmaceutical compounds - which belong to antihypertensive and anti-ulcer agents - from surface water samples. The selection of pharmaceuticals was based on usage frequency in Hungary. During method development Oasis HLB, SampliQ Polymer SCX and Si-SCX SPE cartridges were tested. As LC eluent ammonium formate. ammonium acetate buffers at pH 3 and 5 were investigated and for quantitation both matrix-matched and internal standard calibration was used. For matrix effect assessment post-extraction spike method was applied which can separate the extraction efficiency from ion suppression for better determination of recovery. Method detection limits (MDLs) varied between 0.2 and 10 ng/L. Precision of the method, calculated as relative standard deviation (RSD), ranged from 0.2 to 14.6% and from 1.2 to 22.4% for intra- and inter-day analysis, respectively. The method was applied to analyze Danube water samples. Measured average concentrations varied between 2 and 39 ng/L for eleven compounds and another one could be detected under LOQ (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1447 / 1454
页数:8
相关论文
共 50 条
  • [31] Determination of glyphosate, AMPA, and glufosinate in honey by online solid-phase extraction-liquid chromatography-tandem mass spectrometry
    Thompson, Thomas S.
    van den Heever, Johan P.
    Limanowka, Renata E.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2019, 36 (03): : 434 - 446
  • [32] Monolithic molecularly imprinted solid-phase extraction for the selective determination of trace cytokinins in plant samples with liquid chromatography-electrospray tandem mass spectrometry
    Du, Fuyou
    Ruan, Guihua
    Liang, Shenghua
    Xie, Fuwei
    Liu, Huwei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (02) : 489 - 501
  • [33] A nanoparticle-based solid-phase extraction method for liquid chromatography-electrospray ionization-tandem mass spectrometric analysis
    Song, Yaru
    Zhao, Shulin
    Tchounwou, Paul
    Liu, Yi-Ming
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1166 (1-2) : 79 - 84
  • [34] Determination of benzodiazepines in human urine using solid-phase extraction and high-performance liquid chromatography-electrospray ionization tandern mass spectrometry
    Hegstad, S
    Oiestad, EL
    Johansen, U
    Christophersen, AS
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2006, 30 (01) : 31 - 37
  • [35] Determination of hexaconazole in surface water samples from river and the sea by liquid chromatography-electrospray tandem mass spectrometry
    Tsukatani, Hiroko
    Tobiishi, Kazuhiro
    Tanaka, Yoshito
    Sakuragi, Kenji
    Ikeura, Tasoh
    Nakamura, Matayoshi
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2008, 72 (01) : 149 - 154
  • [36] Picogram per liter level determination of estrogens in natural waters and waterworks by a fully automated on-line solid-phase extraction-liquid chromatography-electrospray tandem mass spectrometry method
    Rodriguez-Mozaz, S
    de Alda, MJL
    Barceló, D
    ANALYTICAL CHEMISTRY, 2004, 76 (23) : 6998 - 7006
  • [37] Determination of phthalates in vegetables by liquid chromatography-electrospray ionization mass spectrometry with matrix solid phase dispersion
    Wang Li-Xia
    Kou Li-Juan
    Pan Feng-Yun
    Wang Ming-Lin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (11) : 1559 - 1564
  • [38] Determination of surfactants in surface water by solid-phase extraction, liquid chromatography and liquid chromatography-mass spectrometry
    Scullion, SD
    Clench, MR
    Cooke, M
    Ashcroft, AE
    JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) : 207 - 216
  • [39] Determination of domoic acid in seawater by solid phase extraction-liquid chromatography-tandem mass spectrometry
    Wang Jiuming
    Chen Junhui
    Yang Jianbo
    He Xiuping
    Wang Yuning
    Wang Baodong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (08) : 889 - 895
  • [40] Determination of Chlormequat in Muscles of Mice by Solid Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry
    Li Chun-Mei
    Jin Fen
    Xu Si-Yuan
    Liu Jia-Jia
    Jin Mao-Jun
    Shao Hua
    Wang Jing
    Yang Ming-Qi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (12) : 1924 - 1928