Numerical and experimental investigation of kerf depth effect on high-frequency phased array transducer

被引:8
|
作者
Zhang, J. Y. [1 ,2 ,3 ]
Xu, W. J. [2 ]
Carlier, J. [2 ]
Ji, X. M. [1 ,3 ]
Queste, S. [4 ]
Nongaillard, B. [2 ]
Huang, Y. P. [1 ,3 ]
机构
[1] Fudan Univ, Dept Microelect, ASIC, Shanghai 200433, Peoples R China
[2] Univ Valenciennes, CNRS, UMR 8520, IEMN,Dept OAE, F-59313 Valenciennes, France
[3] Fudan Univ, Dept Microelect, Syst State Key Lab, Shanghai 200433, Peoples R China
[4] Univ Franche Comte, CNRS, UMR 6174, Inst FEMTO ST, F-25044 Besancon, France
基金
美国国家科学基金会;
关键词
High-frequency; Single crystal lithium niobate (LiNbO3); Linear arrays; Micromachining;
D O I
10.1016/j.ultras.2011.08.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Background: High-frequency ultrasonic transducer arrays are essential for high resolution imaging in clinical analysis and Non-Destructive Evaluation (NDE). However, the structure design and fabrication of the kerfed ultrasonic array is quite challenging when very high frequency (>= 100 MHz) is required. Objective and method: Here we investigate the effect of kerf depth on the performances of array transducers. A finite element tool, COMSOL, is employed to simulate the properties of acoustic field and to calculate the electrical properties of the arrays, including crosstalk effect and electrical impedance. Furthermore, Inductively Coupled Plasma (ICP) deep etching process is used to etch 36 degrees/Y-cut lithium niobate (LiNbO3) crystals and the limitation of etching aspect ratio is studied. Several arrays with different profiles are realized under optimized processes. At last, arrays with a pitch of 25 mu m and 40 mu m are fabricated and characterized by a network analyzer. Results: Kerf depth plays an important role in the performance of the transducer array. The crosstalk is proportional to kerf depth. When kerf depth is more than 13 mu m, the array with crosstalk less than -20 dB, which is acceptable for the real application, could provide a desired resolution. Compared to beam focusing, kerf depth exhibits more effect on the beam steering/focusing. The lateral pressure distribution is quantitatively summarized for four types of arrays with different kerf depth. The results of halfcut array are similar to those of the full-cut one in both cases of focusing and steering/focusing. The Full-Width-at-Half-Maximum (FWHM) is 55 mu m for the half-cut array, and is 42 mu m for the full-cut one. The 5-mu m-cut array, suffering from severe undesired lobes, demonstrates similar behaviors with the no-cut one. ICP process is used to etch the 36 degrees/Y-cut LiNbO3 film. The aspect ratio of etching profile increases with the kerf width decreasing till it stops by forming a V-shaped groove, and the positive tapered profile angle ranges between 62 degrees and 80 degrees. If the mask selectivity does not limit the process in terms of achievable depth, the aspect ratio is limited to values around 1.3. The measurement shows the electrical impedance and crosstalk are consistent with the numerical calculation. Conclusion: The numerical results indicate that half-cut array is a promising alternative for the fabrication of high-frequency ultrasonic linear arrays. In fact, the minimum pitch that could be obtained is around 25 mu m, equivalent to a pitch of 1.6 lambda, with a kerf depth of 16 mu m under the optimized ICP parameters. Crown Copyright (C) 2011 Published by Elsevier B. V. All rights reserved.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 50 条
  • [41] On the experimental investigation of high-frequency dielectric sealing of PVC
    Brahimi, B
    Yilmazer, U
    ANTEC 2000: SOCIETY OF PLASTICS ENGINEERS TECHNICAL PAPERS, CONFERENCE PROCEEDINGS, VOLS I-III, 2000, : 1264 - 1268
  • [42] Experimental and Numerical Investigation of Parameters Affecting High-Frequency Irreversible Electroporation for Prostate Cancer Ablation
    Aycock, Kenneth N.
    Vadlamani, Ram Anand
    Jacobs, Edward J.
    Imran, Khan Mohammad
    Verbridge, Scott S.
    Allen, Irving C.
    Manuchehrabadi, Navid
    Davalos, Rafael V.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (06):
  • [44] Numerical evaluation of the effect of electronically steering a phased array transducer: axially post-focal shifting
    Wang, Mingjun
    Zhou, Yufeng
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2017, 33 (07) : 758 - 769
  • [45] Development of a High Frequency Forward-looking Phased-array Transducer in Guiding Interventional Procedures
    Lv, Jiabing
    Wang, Ninghao
    Gao, Feng
    Shen, Zhitian
    Cui, Yaoyao
    Li, Hongwei
    Jian, Xiaohua
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [46] Experimental characterization of fundamental and second harmonic beams for a high-frequency ultrasound transducer
    Cherin, EW
    Poulsen, JK
    van der Steen, AFW
    Lum, P
    Foster, FS
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (05): : 635 - 646
  • [47] A Low-Cost 10 mm Diameter Histotripsy Transducer for Tissue Ablation Guided by a co-Registered High-Frequency Endoscopic Phased Array
    Woodacre, J. K.
    Landry, T. G.
    Brown, J. A.
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [48] Partial Discharge Analysis in High-Frequency Transformer Based on High-Frequency Current Transducer
    Jiang, Jun
    Zhao, Mingxin
    Zhang, Chaohai
    Chen, Min
    Liu, Haojun
    Albarracin, Ricardo
    ENERGIES, 2018, 11 (08)
  • [49] Novel Water Probe for High-Frequency Focused Transducer Applied to Scanning Acoustic Microscopy System: Simulation and Experimental Investigation
    Pham, Van Hiep
    Tran, Le Hai
    Choi, Jaeyeop
    Truong, Hoanh-Son
    Vo, Tan Hung
    Vu, Dinh Dat
    Park, Sumin
    Oh, Junghwan
    SENSORS, 2024, 24 (16)
  • [50] Non Direction High-frequency Underwater Transducer
    Wang, G.
    Qin, L.
    Wang, L. K.
    SECOND INTERNATIONAL CONFERENCE ON SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING, 2009, 7493