Ultra Low Dose CT Pulmonary Angiography with Iterative Reconstruction

被引:45
|
作者
Sauter, Andreas [1 ]
Koehler, Thomas [2 ]
Fingerle, Alexander A. [1 ]
Brendel, Bernhard [2 ]
Richter, Vivien [3 ]
Rasper, Michael [1 ]
Rummeny, Ernst J. [1 ]
Noel, Peter B. [1 ,4 ,5 ]
Muenzel, Daniela [1 ]
机构
[1] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Munich, Germany
[2] Philips GmbH, Innovat Technol, Res Labs, Hamburg, Germany
[3] Univ Klinikum Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[4] Tech Univ Munich, Lehrstuhl Biomed Phys, Dept Phys, Garching, Germany
[5] Tech Univ Munich, Inst Med Tech, Garching, Germany
来源
PLOS ONE | 2016年 / 11卷 / 09期
关键词
LOW-TUBE-VOLTAGE; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; ABDOMINAL CT; RADIATION; REDUCTION; EMBOLISM; ALGORITHM; CHEST; IMPACT;
D O I
10.1371/journal.pone.0162716
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective Evaluation of a new iterative reconstruction algorithm (IMR) for detection/rule-out of pulmonary embolism (PE) in ultra-low dose computed tomography pulmonary angiography (CTPA). Methods Lower dose CT data sets were simulated based on CTPA examinations of 16 patients with pulmonary embolism (PE) with dose levels (DL) of 50%, 25%, 12.5%, 6.3% or 3.1% of the original tube current setting. Original CT data sets and simulated low-dose data sets were reconstructed with three reconstruction algorithms: the standard reconstruction algorithm "filtered back projection" (FBP), the first generation iterative reconstruction algorithm iDose and the next generation iterative reconstruction algorithm "Iterative Model Reconstruction" (IMR). In total, 288 CTPA data sets (16 patients, 6 tube current levels, 3 different algorithms) were evaluated by two blinded radiologists regarding image quality, diagnostic confidence, detectability of PE and contrast-to-noise ratio (CNR). Results iDose and IMR showed better detectability of PE than FBP. With IMR, sensitivity for detection of PE was 100% down to a dose level of 12.5%. iDose and IMR showed superiority to FBP regarding all characteristics of subjective (diagnostic confidence in detection of PE, image quality, image noise, artefacts) and objective image quality. The minimum DL providing acceptable diagnostic performance was 12.5% (= 0.45 mSv) for IMR, 25% (= 0.89 mSv) for iDose and 100% (= 3.57 mSv) for FBP. CNR was significantly (p < 0.001) improved by IMR compared to FBP and iDose at all dose levels. Conclusion By using IMR for detection of PE, dose reduction for CTPA of up to 75% is possible while maintaining full diagnostic confidence. This would result in a mean effective dose of approximately 0.9 mSv for CTPA.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction
    Kim, Hae Jin
    Yoo, So-Young
    Jeon, Tae Yeon
    Kim, Ji Hye
    CLINICAL IMAGING, 2016, 40 (05) : 1018 - 1022
  • [22] Stent evaluation in low-dose coronary CT angiography: Effect of different iterative reconstruction settings
    Wuest, Wolfgang
    May, Matthias S.
    Scharf, Michael
    Layritz, Christian
    Eisentopf, Jasmin
    Ropers, Dieter
    Pflederer, Tobias
    Uder, Michael
    Achenbach, Stephan
    Lell, Michael M.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (05) : 319 - 325
  • [23] Feasibility of an ultra low dose CT for left atrium and pulmonary veins imaging using a new model-based iterative reconstruction
    Annoni, A.
    Andreini, D.
    Formenti, A.
    Pontone, G.
    Mushtaq, S.
    Bertella, E.
    Petulla, M.
    Nobili, E.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 200 - 200
  • [24] Low-Dose Thoracic Aorta MDCT Angiography With Iterative Reconstruction
    Tore, H.
    Chalian, H.
    Entezari, P.
    Miller, J.
    Yaghmai, V
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [25] Coronary CT angiography: Comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT-Initial experience
    Takx, Richard A. P.
    Schoepf, U. Joseph
    Moscariello, Antonio
    Das, Marco
    Rowe, Garrett
    Schoenberg, Stefan O.
    Fink, Christian
    Henzler, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : 275 - 280
  • [26] Ultra-Low-Dose CT of the Thorax Using Iterative Reconstruction: Evaluation of Image Quality and Radiation Dose Reduction
    Kim, Yookyung
    Kim, Yoon Kyung
    Lee, Bo Eun
    Lee, Seok Jeong
    Ryu, Yon Ju
    Lee, Jin Hwa
    Chang, Jung Hyun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (06) : 1197 - 1202
  • [27] Ultra-low-dose chest CT with iterative reconstruction does not alter anatomical image quality
    Macri, F.
    Greffier, J.
    Pereira, F. R.
    Mandoul, C.
    Khasanova, E.
    Gualdi, G.
    Beregi, J. P.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (11) : 1131 - 1140
  • [28] Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT
    Xu, Yan
    He, Wen
    Chen, Hui
    Hu, Zhihai
    Li, Juan
    Zhang, Tingting
    CLINICAL RADIOLOGY, 2013, 68 (09) : 902 - 908
  • [29] Multiple Adversarial Learning Based Angiography Reconstruction for Ultra-Low-Dose Contrast Medium CT
    Zhang, Weiwei
    Zhou, Zhen
    Gao, Zhifan
    Yang, Guang
    Xu, Lei
    Wu, Weiwen
    Zhang, Heye
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (01) : 409 - 420
  • [30] Previous-stage-based ROI Reconstruction Method for Ultra-low-dose CT Angiography
    Zhou, Yufu
    Zhang, Xinzhen
    Zhang, Weikang
    Sun, Jianqi
    Zhao, Jun
    2020 IEEE 20TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE 2020), 2020, : 969 - 974