Ultra Low Dose CT Pulmonary Angiography with Iterative Reconstruction

被引:45
|
作者
Sauter, Andreas [1 ]
Koehler, Thomas [2 ]
Fingerle, Alexander A. [1 ]
Brendel, Bernhard [2 ]
Richter, Vivien [3 ]
Rasper, Michael [1 ]
Rummeny, Ernst J. [1 ]
Noel, Peter B. [1 ,4 ,5 ]
Muenzel, Daniela [1 ]
机构
[1] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Munich, Germany
[2] Philips GmbH, Innovat Technol, Res Labs, Hamburg, Germany
[3] Univ Klinikum Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[4] Tech Univ Munich, Lehrstuhl Biomed Phys, Dept Phys, Garching, Germany
[5] Tech Univ Munich, Inst Med Tech, Garching, Germany
来源
PLOS ONE | 2016年 / 11卷 / 09期
关键词
LOW-TUBE-VOLTAGE; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; ABDOMINAL CT; RADIATION; REDUCTION; EMBOLISM; ALGORITHM; CHEST; IMPACT;
D O I
10.1371/journal.pone.0162716
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective Evaluation of a new iterative reconstruction algorithm (IMR) for detection/rule-out of pulmonary embolism (PE) in ultra-low dose computed tomography pulmonary angiography (CTPA). Methods Lower dose CT data sets were simulated based on CTPA examinations of 16 patients with pulmonary embolism (PE) with dose levels (DL) of 50%, 25%, 12.5%, 6.3% or 3.1% of the original tube current setting. Original CT data sets and simulated low-dose data sets were reconstructed with three reconstruction algorithms: the standard reconstruction algorithm "filtered back projection" (FBP), the first generation iterative reconstruction algorithm iDose and the next generation iterative reconstruction algorithm "Iterative Model Reconstruction" (IMR). In total, 288 CTPA data sets (16 patients, 6 tube current levels, 3 different algorithms) were evaluated by two blinded radiologists regarding image quality, diagnostic confidence, detectability of PE and contrast-to-noise ratio (CNR). Results iDose and IMR showed better detectability of PE than FBP. With IMR, sensitivity for detection of PE was 100% down to a dose level of 12.5%. iDose and IMR showed superiority to FBP regarding all characteristics of subjective (diagnostic confidence in detection of PE, image quality, image noise, artefacts) and objective image quality. The minimum DL providing acceptable diagnostic performance was 12.5% (= 0.45 mSv) for IMR, 25% (= 0.89 mSv) for iDose and 100% (= 3.57 mSv) for FBP. CNR was significantly (p < 0.001) improved by IMR compared to FBP and iDose at all dose levels. Conclusion By using IMR for detection of PE, dose reduction for CTPA of up to 75% is possible while maintaining full diagnostic confidence. This would result in a mean effective dose of approximately 0.9 mSv for CTPA.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] QUANTITATIVE COMPARISON OF ITERATIVE RECONSTRUCTION ALGORITHMS IN ULTRA-LOW-DOSE CORONARY CT ANGIOGRAPHY
    Benz, Dominik C.
    Fuchs, Tobias
    Grani, Christoph
    Hirt-Moch, Beatrice
    Mikulicic, Fran
    Vontobel, Jan
    Stehli, Julia
    Clerc, Olivier F.
    Possner, Mathias
    Mueller, Ennio
    Pazhenkottil, Aju
    Gaemperli, Oliver
    Buechel, Ronny
    Kaufmann, Philipp
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1740 - 1740
  • [2] Application of ct pulmonary angiography with "Ultra-Double-Low" and iterative model reconstruction for acute pulmonary embolism
    Bai, Jiayuan
    Zhang, Wanjun
    Zhang, Wei
    Zhang, Bo
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (03) : 270 - 276
  • [3] Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose
    Sui, Xin
    Meinel, Felix G.
    Song, Wei
    Xu, Xiaoli
    Wang, Zixing
    Wang, Yuyan
    Jin, Zhengyu
    Chen, Jiuhong
    Vliegenthart, Rozemarijn
    Schoepf, U. Joseph
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (03) : 564 - 570
  • [4] Improved image quality and low radiation dose with hybrid iterative reconstruction with 80 kV CT pulmonary angiography
    Laqmani, Azien
    Regier, Marc
    Veldhoen, Simon
    Backhaus, Alexandra
    Wassenberg, Felicia
    Sehner, Susanne
    Groth, Michael
    Nagel, Hans-Dieter
    Adam, Gerhard
    Henes, Frank O.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1962 - 1969
  • [5] CT pulmonary angiography: dose reduction via a next generation iterative reconstruction algorithm
    Sauter, Andreas
    Koehler, Thomas
    Brendel, Bernhard
    Aichele, Juliane
    Neumann, Jan
    Noel, Peter B.
    Rummeny, Ernst J.
    Muenzel, Daniela
    ACTA RADIOLOGICA, 2019, 60 (04) : 478 - 487
  • [6] Ultra-low radiation dose CT angiography of the lower extremity using the iterative model reconstruction (IMR) algorithm
    Qian, W-L.
    Zhou, D. -J.
    Jiang, Y.
    Feng, C.
    Chen, Q.
    Wang, H.
    Zhang, J. -B.
    Xu, J. -M.
    CLINICAL RADIOLOGY, 2018, 73 (11) : 985.e13 - 985.e19
  • [7] Hybrid iterative reconstruction in ultra-low-dose CT for accurate pulmonary nodule assessment: A Phantom study
    Chen, Li-Guo
    Kao, Hung-Wen
    Wu, Ping-An
    Sheu, Ming-Huei
    Tu, Hsing-Yang
    Huang, Li-Chuan
    MEDICINE, 2025, 104 (08)
  • [8] Clinical Application of Iterative Reconstruction Technology in Ultra Low Dose Chest CT
    Wang, Qi
    Geng, Hai
    Bai, Huanguang
    Wang, Rongfang
    Dong, Guang
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (08) : 1599 - 1602
  • [9] Lung nodules assessment in ultra-low-dose CT with iterative reconstruction compared to conventional dose CT
    Jin, Shiqi
    Zhang, Bo
    Zhang, Lina
    Li, Shu
    Li, Songbai
    Li, Peiling
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2018, 8 (05) : 480 - 490
  • [10] The influence of iterative reconstruction level on image quality and radiation dose in CT pulmonary angiography examinations
    Harun, H.H.
    Karim, M.K.A.
    Abbas, Z.
    Sabarudin, A.
    Muniandy, S.C.
    Razak, H.R.A.
    Ng, K.H.
    Radiation Physics and Chemistry, 2021, 178