Relation between bone density and primary implant stability

被引:63
|
作者
Farre-Pages, Nuria [1 ]
Auge-Castro, Ma Luisa [1 ]
Alaejos-Algarra, Fernando [1 ]
Mareque-Bueno, Javier [1 ]
Ferres-Padro, Eduard [1 ]
Hernandez-Alfaro, Federico [1 ]
机构
[1] Univ Int Catalunya, Fac Dent, Med Surg & Oral Implantol Dept, Barcelona 08195, Spain
来源
关键词
Hounsfield unit; bone quality; implant stability; computerized tomography (CT scan); dental im-; COMPUTERIZED-TOMOGRAPHY VALUES; RESONANCE FREQUENCY; CUTTING TORQUE; ASSESSMENTS; SITES; CLASSIFICATION; PLACEMENT;
D O I
10.4317/medoral.16.e62
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims: This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). Materials and Methods: Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluation of bone density for each patient. The bone mean density around planned implants was determined with Physioplanet TM software. Bone quality according resistance to drilling, insertion torque and resonance frequency measurements were recorded. Results: A statistically significant relationship was observed between bone quality density and location with ISQ values. Conclusions: This research demonstrates a strong relationship between the bone density values from computerized tomography and the location in the maxillaries. A correlation exists between bone quality, according to the Lekholm & Zarb classification, and Hu computerized tomography values. The primary implant stability measured with resonance frequency analysis depends on bone density values, bone quality and implant location.
引用
收藏
页码:E62 / E67
页数:6
相关论文
共 50 条
  • [21] Computational analysis of primary implant stability in trabecular bone
    Steiner, Juri A.
    Ferguson, Stephen J.
    van Lenthe, G. Harry
    JOURNAL OF BIOMECHANICS, 2015, 48 (05) : 807 - 815
  • [22] A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment
    Alsaadi, Ghada
    Quirynen, Marc
    Michiels, Katleen
    Jacobs, Reinhilde
    van Steenberghe, Daniel
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) : 359 - 366
  • [23] Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks
    Wakamatsu, Kaien
    Doi, Kazuya
    Kobatake, Reiko
    Oki, Yoshifumi
    Tsuga, Kazuhiro
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (06):
  • [24] Relationship between cortical bone thickness or computerized tomography-derived bone density values and implant stability
    Merheb, Joe
    Van Assche, Nele
    Coucke, Wim
    Jacobs, Reinhilde
    Naert, Ignace
    Quirynen, Marc
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (06) : 612 - 617
  • [25] Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study
    Lee, Jungwon
    Lim, Young-Jun
    Ahn, Jin-Soo
    Kim, Bongju
    Baek, Yeon-Wha
    Lim, Bum-Soon
    PLOS ONE, 2024, 19 (05):
  • [26] Under-Drilling versus Hybrid Osseodensification Technique: Differences in Implant Primary Stability and Bone Density of the Implant Bed Walls
    Delgado-Ruiz, Rafael
    Gold, Joshua
    Marquez, Tanya Somohano
    Romanos, Georgios
    MATERIALS, 2020, 13 (02)
  • [27] Relation between Spongy Bone Density in the Maxilla and Skeletal Bone Density
    Merheb, Joe
    Temmerman, Andy
    Coucke, Wim
    Rasmusson, Lars
    Kuebler, Alexander
    Thor, Andreas
    Quirynen, Marc
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (06) : 1180 - 1187
  • [28] Evaluation of Peri-Implant Crestal Bone Loss with Different Implant Systems, Primary Stability, Bone Density and Soft Tissue Thickness: A Retrospective Study
    Shenoy A.
    Rohinikumar S.
    Maiti S.
    Sivaswamy V.
    Rajaraman V.
    Journal of Long-Term Effects of Medical Implants, 2023, 33 (04) : 53 - 58
  • [29] Effect of surgical techniques on primary implant stability and peri-implant bone
    Fanuscu, Mete I.
    Chang, Ting-Ling
    Akca, Kivanc
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (12) : 2487 - 2491
  • [30] Correlation between Primary Stability of Dental Implants and Bone Density: A Retrospective Analysis
    Padmaja S.
    Rajasekar A.
    Journal of Long-Term Effects of Medical Implants, 2024, 34 (04) : 65 - 70