摘要
Calibration model transfer is an important issue in infrared spectra analysis. For identical sample, spectra collected with master and slave spectrometers share same components. In the sense of mathematics, they share same basis. If the basis and corresponding coefficient matrices can be obtained, the model transfer can be efficiently realized. On the other hand, the performance of calibration model transfer method will degrade if there are outliers and noise in samples. In this paper, a robust calibration transfer model is proposed. Cauchy estimator are employed to learn same basis shared by master and slave spectra robustly. Transformation matrix can be calculated with the two corresponding coefficient matrices. Slave testing spectra are represented with the common basis and corresponding coefficients are then transferred using the transformation matrix. The slave testing spectra can be transferred using common basis and the corrected coefficients. The convergence property and bound of proposed model are also discussed. Extensive experiments are conducted, experimental results demonstrate that our robust calibration transfer model can generally outperform the existing methods. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 50 条
  • [41] Spline-based specimen shape optimization for robust material model calibration
    Morgane Chapelier
    Robin Bouclier
    Jean-Charles Passieux
    Advanced Modeling and Simulation in Engineering Sciences, 9
  • [42] A stable and robust calibration scheme of the log-periodic power law model
    Filimonov, V.
    Sornette, D.
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2013, 392 (17) : 3698 - 3707
  • [43] A Computationally Efficient and Robust Kinematic Calibration Model for Industrial Robots with Kinematic Parallelogram
    Lin, Yang
    Zhao, Huan
    Ye, Congcong
    Ding, Han
    2017 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (IEEE ROBIO 2017), 2017, : 1334 - 1339
  • [44] Robust Bayesian Calibration of a k - ε Model for Compressible Jet-in-Crossflow Simulations
    Ray, Jaideep
    Dechant, Lawrence
    Lefantzi, Sophia
    Ling, Julia
    Arunajatesan, Srinivasan
    AIAA JOURNAL, 2018, 56 (12) : 4893 - 4909
  • [45] Multi-response robust optimization using GP model with variance calibration
    Feng, Zebiao
    Wang, Jianjun
    Ma, Yizhong
    Zhou, Xiaojian
    COMPUTERS & INDUSTRIAL ENGINEERING, 2022, 169
  • [46] Robust water quality model calibration using an alternating fitness genetic algorithm
    Zou, R
    Lung, WS
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 2004, 130 (06): : 471 - 479
  • [47] APPLICATION OF ROBUST CALIBRATION TO RADIOIMMUNOASSAY
    TIEDE, JJ
    PAGANO, M
    BIOMETRICS, 1979, 35 (03) : 567 - 574
  • [48] Robust absolute calibration for SAR
    Crisp, David J.
    2018 INTERNATIONAL CONFERENCE ON RADAR (RADAR), 2018,
  • [49] Robust active stereo calibration
    Neubert, J
    Ferrier, NJ
    2002 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2002, : 2525 - 2531
  • [50] ROBUST DIAGNOSTICS IN MULTIVARIATE CALIBRATION
    CHEN, WC
    CUI, H
    LIANG, YZ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1995, 16 (09): : 1349 - 1354