Robust calibration model transfer

被引:12
|
作者
Mou, Yi [1 ]
Zhou, Long [1 ]
Yu, Shujian [3 ]
Chen, WeiZhen [1 ]
Zhao, Xu [1 ]
You, Xinge [2 ]
机构
[1] Wuhan Polytech Univ, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Dept Elect & Informat Engn, Wuhan 430074, Peoples R China
[3] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
关键词
Infrared spectra; Model transfer; Subspace learning; MULTIVARIATE CALIBRATION; INSTRUMENT STANDARDIZATION; SPECTROMETERS; PROJECTIONS;
D O I
10.1016/j.chemolab.2016.05.014
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Calibration model transfer is an important issue in infrared spectra analysis. For identical sample, spectra collected with master and slave spectrometers share same components. In the sense of mathematics, they share same basis. If the basis and corresponding coefficient matrices can be obtained, the model transfer can be efficiently realized. On the other hand, the performance of calibration model transfer method will degrade if there are outliers and noise in samples. In this paper, a robust calibration transfer model is proposed. Cauchy estimator are employed to learn same basis shared by master and slave spectra robustly. Transformation matrix can be calculated with the two corresponding coefficient matrices. Slave testing spectra are represented with the common basis and corresponding coefficients are then transferred using the transformation matrix. The slave testing spectra can be transferred using common basis and the corrected coefficients. The convergence property and bound of proposed model are also discussed. Extensive experiments are conducted, experimental results demonstrate that our robust calibration transfer model can generally outperform the existing methods. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 50 条
  • [1] A Robust Near-Infrared Calibration Model for the Determination of Chlorophyll Concentration in Tree Leaves with a Calibration Transfer Method
    Wang, Man
    Zheng, Kaiyi
    Yang, Guijuan
    Ma, Wenjun
    Wang, Junhui
    Wang, Tianyi
    Du, Yiping
    ANALYTICAL LETTERS, 2015, 48 (11) : 1707 - 1719
  • [2] Robust Probabilistic Multivariate Calibration Model
    Fang, Yi
    Jeong, Myong K.
    TECHNOMETRICS, 2008, 50 (03) : 305 - 316
  • [3] Robust experimental designs for model calibration
    Krishna, Arvind
    Joseph, V. Roshan
    Ba, Shan
    Brenneman, William A.
    Myers, William R.
    JOURNAL OF QUALITY TECHNOLOGY, 2022, 54 (04) : 441 - 452
  • [4] Model Transfer in Multivariate Calibration
    Chu, Xiao-Li
    Yuan, Hong-Fu
    Lu, Wan-Zhen
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2001, 21 (06): : 884 - 885
  • [5] Model transfer in multivariate calibration
    Chu, XL
    Yuan, HF
    Lu, WZ
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2001, 21 (06) : 881 - 885
  • [6] Calibration transfer employing univariate correction and robust regression
    Harrop Galvao, Roberto Kawakami
    Carreiro Soares, Sofacles Figueredo
    Martins, Marcelo Nascimento
    Pimentel, Maria Fernanda
    Ugulino Araujo, Mario Cesar
    ANALYTICA CHIMICA ACTA, 2015, 864 : 1 - 8
  • [7] Fast model selection for robust calibration methods
    Engelen, S
    Hubert, M
    ANALYTICA CHIMICA ACTA, 2005, 544 (1-2) : 219 - 228
  • [8] Multivariate calibration maintenance and transfer through robust fused LASSO
    Kunz, M. Ross
    She, Yiyuan
    JOURNAL OF CHEMOMETRICS, 2013, 27 (09) : 233 - 242
  • [9] Robust modeling for multivariate calibration transfer by the successive projections algorithm
    Honorato, FA
    Galvao, RKH
    Pimentel, MF
    Neto, BD
    Araújo, MCU
    de Carvalho, FR
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2005, 76 (01) : 65 - 72
  • [10] Simultaneous tracking and RSS model calibration by robust filtering
    Manuel Castro-Arvizu, J.
    Vila-Valls, Jordi
    Closas, Pau
    Fernandez-Rubio, Juan A.
    CONFERENCE RECORD OF THE 2014 FORTY-EIGHTH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS & COMPUTERS, 2014, : 706 - 710