Predictive value of noninducibility after catheter ablation for paroxysmal and persistent atrial fibrillation
被引:3
|
作者:
Tachibana, Shinichi
论文数: 0引用数: 0
h-index: 0
机构:
Yokohama City Minato Red Cross Hosp, Dept Cardiol, Yokohama, Kanagawa, JapanYokohama City Minato Red Cross Hosp, Dept Cardiol, Yokohama, Kanagawa, Japan
Tachibana, Shinichi
[1
]
Mizukami, Akira
论文数: 0引用数: 0
h-index: 0
机构:
Kameda Med Ctr, Dept Cardiol, 929 Higashi Cho, Kamogawa, Chiba 2968602, JapanYokohama City Minato Red Cross Hosp, Dept Cardiol, Yokohama, Kanagawa, Japan
Mizukami, Akira
[2
]
Kuroda, Shunsuke
论文数: 0引用数: 0
h-index: 0
机构:
Cleveland Clin, Cardiovasc Med Dept, Cleveland, OH 44106 USAYokohama City Minato Red Cross Hosp, Dept Cardiol, Yokohama, Kanagawa, Japan
Kuroda, Shunsuke
[3
]
Hayashi, Tatsuya
论文数: 0引用数: 0
h-index: 0
机构:
Tokyo Med & Dent Univ, Cardiovasc Med, Tokyo, JapanYokohama City Minato Red Cross Hosp, Dept Cardiol, Yokohama, Kanagawa, Japan
Hayashi, Tatsuya
[4
]
Matsumura, Akihiko
论文数: 0引用数: 0
h-index: 0
机构:
Kameda Med Ctr, Dept Cardiol, 929 Higashi Cho, Kamogawa, Chiba 2968602, JapanYokohama City Minato Red Cross Hosp, Dept Cardiol, Yokohama, Kanagawa, Japan
Matsumura, Akihiko
[2
]
Goya, Masahiko
论文数: 0引用数: 0
h-index: 0
机构:
Tokyo Med & Dent Univ, Cardiovasc Med, Tokyo, JapanYokohama City Minato Red Cross Hosp, Dept Cardiol, Yokohama, Kanagawa, Japan
Goya, Masahiko
[4
]
Sasano, Tetsuo
论文数: 0引用数: 0
h-index: 0
机构:
Tokyo Med & Dent Univ, Cardiovasc Med, Tokyo, JapanYokohama City Minato Red Cross Hosp, Dept Cardiol, Yokohama, Kanagawa, Japan
Sasano, Tetsuo
[4
]
机构:
[1] Yokohama City Minato Red Cross Hosp, Dept Cardiol, Yokohama, Kanagawa, Japan
[2] Kameda Med Ctr, Dept Cardiol, 929 Higashi Cho, Kamogawa, Chiba 2968602, Japan
[3] Cleveland Clin, Cardiovasc Med Dept, Cleveland, OH 44106 USA
[4] Tokyo Med & Dent Univ, Cardiovasc Med, Tokyo, Japan
Background It is unclear whether pacing maneuver at the end of catheter ablation for atrial fibrillation (AF) predicts recurrence of atrial tachyarrhythmia postintervention. Objective To investigate whether the predictive value of incremental pacing maneuver after catheter ablation for AF depends on the pacing cycle length and type of AF. Methods This study included 298 consecutive patients who underwent initial catheter ablation for nonvalvular AF (61% paroxysmal AF [PAF], 39% persistent AF [PeAF]). Rapid atrial pacing was performed at the end of the procedure. We analyzed minimum coupling interval (CI) of pacing, arrhythmia-inducibility, and atrial tachyarrhythmia recurrence in patients with PAF and PeAF. Results Patients were divided into the following three groups according to their response to pacing maneuver: AF-inducible (inducible group; n = 86), noninducible at CI >= 200 ms (non-CI >= 200 group; n = 100), and noninducible at CI <200 ms (non-CI <200 group; n = 112). Kaplan-Meier analysis showed that response to pacing maneuver was significantly associated with recurrence of atrial tachyarrhythmias (P = .028). Cox-regression analysis showed that non-CI <200 was an independent predictor when the inducible group was used as a reference (hazard ratio 0.60, 95% confidence interval 0.40-0.96, P = .031). However, when PAF and PeAF were analyzed separately, non-CI Noninducibility with shorter CI predicted atrial tachyarrhythmia recurrence only for PeAF. Pacing CI and type of AF could influence the predictive value of atrial tachyarrhythmia recurrence.