The St. jude medical cardiac valve prosthesis: A 25-year experience with single valve replacement

被引:133
|
作者
Emery, RW [1 ]
Krogh, CC [1 ]
Arom, KV [1 ]
Emery, AM [1 ]
Benyo-Albrecht, K [1 ]
Joyce, LD [1 ]
Nicoloff, DM [1 ]
机构
[1] Cardiac Surg Associates, St Paul, MN 55114 USA
来源
ANNALS OF THORACIC SURGERY | 2005年 / 79卷 / 03期
关键词
D O I
10.1016/j.athoracsur.2004.08.047
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. From October 1977 to October 2002, 4,480 patients (age range, 17 to 94 years; average, 64 +/- 13 years) underwent single valve replacement with the St. Jude Medical heart valve. Of 2,982 aortic (AVR) and 1,498 mitral valve replacements (MVR), concomitant coronary artery bypass grafting was performed on 42% and 33%, respectively. Methods. Cardiac Surgical Associates has maintained an independent database of patients having valve replacement with the St. Jude Medical prosthesis since the world's first implant. Patients were contacted by questionnaire or phone from November 2002 through June 2003. Hospital course and valve-related events were verified by patient chart review or physician contact. Results. Follow-up was 95% complete. Operative mortality was 4% with AVR and 9% with MVR. Total follow-up was 32,190 patient-years (range, I month to 24.8 years; average, 7 +/- 5 years). During the study period, patient freedom from late mortality was 61% (AVR, 61%; MVR, 63%), and from valve-related mortality 92% (AVR, 93%; MVR, 91%). Freedom from thromboembolic events was 85% (86% AVR, 81% MVR), from bleeding events, 81% (81% AVR, 81% MVR), from reoperation, 98% (99% AVR, 97% MVR), from endocarditis, 98% (99% AVR, 98% MVR), and from valve thrombosis, 99% (99% AVR, 98% MVR). There was one MVR structural failure (0.06%). Conclusions. The St. Jude Medical valve has proven to be an effective and durable valve prosthesis with a low event rate during the long term.
引用
收藏
页码:776 / 783
页数:8
相关论文
共 50 条
  • [31] ST JUDE MEDICAL CARDIAC-VALVE PROSTHESIS IN INFANTS AND CHILDREN - EARLY AND INTERMEDIATE EXPERIENCE
    DONAHOO, JS
    GARDNER, TJ
    SOUTHERN MEDICAL JOURNAL, 1982, 75 (12) : 1538 - 1540
  • [32] Silzone™-coated St. Jude Medical valve:: A safe valve
    Houël, R
    Kirsch, M
    Hillion, ML
    Loisance, D
    JOURNAL OF HEART VALVE DISEASE, 2001, 10 (06): : 724 - 727
  • [33] A 7-YEAR EXPERIENCE WITH THE ST JUDE MEDICAL VALVE
    OKANE, H
    GLADSTONE, D
    HAMILTON, L
    CLELAND, J
    BRITISH HEART JOURNAL, 1987, 57 (01): : 101 - 101
  • [34] CLINICAL AND HEMODYNAMIC-RESULTS WITH THE ST JUDE MEDICAL CARDIAC-VALVE PROSTHESIS - A 3-YEAR EXPERIENCE
    NICOLOFF, DM
    EMERY, RW
    AROM, KV
    NORTHRUP, WF
    JORGENSEN, CR
    WANG, Y
    LINDSAY, WG
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1981, 82 (05): : 674 - 683
  • [35] AORTIC AND MITRAL-VALVE REPLACEMENT WITH THE ST-JUDE MEDICAL PROSTHESIS
    CRAWFORD, FA
    KRATZ, JM
    SADE, RM
    STROUD, MR
    BARTLES, DM
    ANNALS OF SURGERY, 1984, 199 (06) : 753 - 761
  • [36] LONGTERM RESULTS OF ST-JUDE-MEDICAL-PROSTHESIS VALVE-REPLACEMENT
    SCHELD, HH
    FRAEDRICH, G
    HOGE, R
    GORLACH, G
    FIEDLER, R
    HEHRLEIN, FW
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 : 47 - 47
  • [37] Hemodynamics and early performance of the St. Jude Medical Regent™ aortic valve prosthesis
    Bach, DS
    Goldbach, M
    Sakwa, MP
    Petracek, M
    Errett, L
    Mohr, F
    JOURNAL OF HEART VALVE DISEASE, 2001, 10 (04): : 436 - 442
  • [38] Thrombotic Thrombocytopenic Purpura Following Aortic Valve Replacement with St. Jude Medical Trifecta Bio-Prosthesis
    D'Alessio, Andrea
    Verdichizzo, Danilo
    Falconieri, Fabio
    Keiralla, Amar
    Abramik, Joanna
    Kasimis, Georgios
    Krasopoulos, George
    CARDIOLOGY RESEARCH, 2018, 9 (06) : 392 - 394
  • [39] ST-JUDE MEDICAL CARDIAC-VALVE PROSTHESIS - INVITRO STUDIES
    EMERY, RW
    NICOLOFF, DM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1979, 78 (02): : 269 - 276
  • [40] The association of aspirin with oral anticoagulant does not reduce morbidity at 1 year after mitral valve replacement with St. Jude medical prosthesis
    Laffort, P
    Roudaut, R
    Rogues, X
    Garrigue, S
    Marazanof, M
    Baudet, M
    Deville, C
    Bonnet, J
    CIRCULATION, 1997, 96 (08) : 2986 - 2986