Potentiometric Determination of Palladium(II) in Aqueous Solutions Using a Modified Carbon-Paste Electrode

被引:3
|
作者
Kholmogorova, A. S. [1 ]
Svintsova, E. A. [1 ]
Neudachina, L. K. [1 ]
Lebedeva, E. L. [1 ]
Puzyrev, I. S. [2 ]
机构
[1] Ural Fed Univ, Ekaterinburg 620002, Russia
[2] Russian Acad Sci, Ural Branch, Postovskii Inst Organ Synth, Ekaterinburg 620990, Russia
关键词
palladium; carbon-paste electrode; potentiometric determination; Pd-600; activator; ION-SELECTIVE ELECTRODES; SILICA; PRECONCENTRATION; SEPARATION; RECOVERY; PLATINUM; SAMPLES; SILVER; GOLD;
D O I
10.1134/S106193482005007X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We studied the main electrode functions of carbon paste electrodes (CPEs) modified with 0-20% of dithiooxamidated polysiloxane with respect to palladium(II). The conditions for the potentiometric titration of palladium(II) using modified CPEs as indicator electrodes were selected, namely, pH 1-2, solutions of EDTA and potassium iodide as the titrants; and modifier concentration is 0, 5, and 10%. A procedure was developed for determining palladium(II) in aqueous solutions. The procedure was tested using a GSO solution of palladium(II) and an industrially produced activator Pd-600.
引用
收藏
页码:679 / 684
页数:6
相关论文
共 50 条
  • [21] Potentiometric determination of urinary iodide using a nanoparticle modified carbon paste electrode
    Wang, Ning
    Wang, Fenfen
    Liao, Yeting
    Liu, Huanhuan
    Li, Yijun
    He, Xiwen
    ANALYTICAL METHODS, 2017, 9 (21) : 3159 - 3165
  • [22] Cyclam modified carbon paste electrode as a potentiometric sensor for determination of cobalt(II) ions
    Pouretedal, HR
    Keshavarz, MH
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2005, 21 (01) : 28 - 31
  • [23] VOLTAMMETRY OF HEXACYANOFERRATES USING A CHEMICALLY MODIFIED CARBON-PASTE ELECTRODE
    KALCHER, K
    ANALYST, 1986, 111 (06) : 625 - 630
  • [24] SELECTIVE DETERMINATION OF PYRIDOXAL WITH AN OCTADECYLAMINE-MODIFIED CARBON-PASTE ELECTRODE
    EGASHIRA, N
    ARAGAKI, S
    IWANAGA, H
    OHGA, K
    ANALYTICAL SCIENCES, 1991, 7 (05) : 691 - 694
  • [25] ON DETERMINATION OF MANGANESE AND LEAD AT CARBON-PASTE ELECTRODE
    MONIEN, H
    ZINKE, K
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1968, 240 (01): : 32 - &
  • [26] Multiwall Carbon Nanotubes Modified Carbon Paste Electrode for Determination of Copper(II) by Potentiometric and Impedimetric Methods
    Mazloum-Ardakani, M.
    Mandegari, A. A.
    Masoum, S.
    Naeimi, H.
    JOURNAL OF NANOSTRUCTURES, 2012, 2 (03) : 333 - 343
  • [27] VOLTAMMETRIC DETERMINATION OF LEAD WITH A CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODE WITH DIPHENYLTHIOCARBAZONE
    MOLINAHOLGADO, T
    PINILLAMACIAS, JM
    HERNANDEZHERNANDEZ, L
    ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) : 117 - 122
  • [28] Electrocatalytic determination of organic thiocarbonyl compounds using a carbon-paste electrode modified with cobalt phthalocyanine
    Popesku, LG
    Shaidarova, LG
    Budnikov, GK
    INDUSTRIAL LABORATORY, 1999, 65 (07): : 423 - 425
  • [29] ELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE ON A PALLADIUM-MODIFIED CARBON-PASTE ELECTRODE
    CAI, XH
    KALCHER, K
    KOLBL, G
    NEUHOLD, C
    DIEWALD, W
    OGOREVC, B
    ELECTROANALYSIS, 1995, 7 (04) : 340 - 345
  • [30] CEPHALOSPORIN ANTIBIOTICS AT CARBON-PASTE AND MODIFIED CARBON-PASTE ELECTRODES IN BOTH AQUEOUS AND BIOLOGICAL MEDIA
    ELMAALI, NA
    GHANDOUR, MA
    KAUFFMANN, JM
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1995, 38 (01): : 91 - 97