Robotic uterine-sparing vesicovaginal fistula repair

被引:5
|
作者
Medina, Luis G. [1 ,2 ]
Hernandez, A. [1 ,2 ]
Sevilla, C. [1 ,2 ]
Cacciamani, G. E. [1 ,2 ,3 ]
Winter, M. [1 ,2 ]
Ashrafi, A. [1 ,2 ]
Gill, I. [1 ,2 ]
Sotelo, R. [1 ,2 ]
机构
[1] Univ Southern Calif, USC Inst Urol, Keck Sch Med, Los Angeles, CA 90007 USA
[2] Univ Southern Calif, Catherine & Joseph Aresty Dept Urol, Keck Sch Med, Los Angeles, CA 90007 USA
[3] Univ Verona, AOUI, Dept Urol, Verona, Italy
关键词
Robotic; Vesicovaginal; Genitourinary; Fistula; Uterine;
D O I
10.1007/s00192-018-3720-5
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The objective was to describe a technique for the robotic repair of complex vesicovaginal fistula (VVF) with uterine preservation. From 2015 to 2017, two patients underwent the procedure. Following placement of the patient in the lithotomy position, catheterization of the fistulous tract and laparoscopic omental harvesting is performed. Then, the robotic system is docked. A transverse incision was made in the peritoneum above the uterus was made to provide access to the bladder, the uterus is mobilized, and a cystotomy is performed to identify the structures. Subsequently, the cystotomy is extended toward the fistulous tract, the plane between the organs is dissected to proceed with the vaginal closure, the vagina is closed, the omental flap is interposed, and the bladder is closed. Mean operative time (OT) was 219 min. Mean estimated blood loss (EBL) was 75 ml. One of the patients had an intraoperative cervix canal injury that was identified and repaired. The postoperative course was uneventful, and the mean length of hospital stay (LOS) was 1 day. A mean follow-up of 17 (+/- 9.89) months showed no recurrence at cystoscopy or imaging evaluation. Uterine-sparing VVF repair is feasible and safe. More studies are needed to assess equivalence compared with other procedures.
引用
收藏
页码:1845 / 1847
页数:3
相关论文
共 50 条
  • [21] EXTRAVESICAL ROBOTIC VESICOVAGINAL FISTULA REPAIR: INITIAL EXPERIENCE AND OUTCOMES
    Ehlert, Michael
    Haraway, Allen
    Atiemo, Humphrey
    NEUROUROLOGY AND URODYNAMICS, 2013, 32 (02) : 176 - 176
  • [22] Robotic Repair of Supratrigonal Vesicovaginal Fistula with Sigmoid Epiploica Interposition
    Sanderson, Derrick J.
    Rutkowski, John
    Attuwaybi, Bashir
    Eddib, Abeer
    JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2018, 22 (04)
  • [23] UTILIZATION AND COMPARATIVE EFFECTIVENESS OF ROBOTIC ASSISTED VESICOVAGINAL FISTULA REPAIR
    Ehlert, Michael
    Sukumar, Shyam
    Atiemo, Humphrey
    Karakiewicz, Pierre I.
    Quoc-Dien Trinh
    NEUROUROLOGY AND URODYNAMICS, 2013, 32 (02) : 186 - 186
  • [24] ROBOTIC-ASSISTED APPROACH TO FAILED VESICOVAGINAL FISTULA REPAIR
    Gorbonos, A.
    Lythgoe, C.
    BJU INTERNATIONAL, 2012, 110 : 136 - 137
  • [25] REPAIR OF VESICOVAGINAL FISTULA
    不详
    POSTGRADUATE MEDICINE, 1974, 55 (04) : 29 - 29
  • [26] Repair of vesicovaginal fistula
    Hertzler, AE
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1929, 17 : 114 - 116
  • [27] REPAIR OF VESICOVAGINAL FISTULA
    NOSZKAY, A
    ACTA CHIRURGICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1963, 4 (04) : 275 - &
  • [28] Repair of vesicovaginal fistula
    Mellish, MH
    ANNALS OF SURGERY, 1916, 63 : 512 - 512
  • [29] Uterine-sparing Laparoscopic Resection of Accessory Cavitated Uterine Masses
    Peters, Ann
    Rindos, Noah B.
    Guido, Richard S.
    Donnellan, Nicole M.
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2018, 25 (01) : 24 - 25
  • [30] Robotic Ureteroneocystotomy and Vesicovaginal Fistula Repair after Cesarean Section Injury
    Lieberman, D.
    Seaman, C.
    Romanova, A.
    Ucpinar, B.
    Hardart, A.
    Tran, A.
    Badani, K.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2022, 33 (SUPPL 2) : S212 - S213