Pressure drop and thermal performance in rotating two-pass ducts with various cross rib arrangements

被引:9
|
作者
Kim, Kyung Min [1 ]
Lee, Dong Hyun [1 ]
Cho, Hyung Hee [1 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul 120749, South Korea
关键词
D O I
10.1007/s00231-007-0331-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present study investigates the pressure drop characteristics of rotating two-pass ducts. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter (D-h) of 26.67 mm. Rib turbulators are attached in the four different cross arrangements on the leading and trailing surfaces of the test ducts. The ribs have a rectangular cross section of 2 turn (e) x 3 mm (w) and a rib angle-of-attack of 70 degrees. The pitch-to-rib-height ratio (p/e) is 7.5 and the rib-height-to-hydraulic-diameter ratio (e/D-h) is 0.075. The measured results for each region show that the highest pressure drop appears in the turning region in the stationary case, but appears in the upstream region of the second pass in the rotating case. The heat transfer and the pressure coefficients in the first pass are similar for the stationary and rotating cases in all the tested rib arrangements. After the turning region, however, the heat transfer and pressure drop are high in the cases with the cross NN- and PP-type ribs in the stationary ducts. In the rotating ducts, they are high in the cases with the cross NP- and PP-type ribs.
引用
收藏
页码:913 / 919
页数:7
相关论文
共 50 条
  • [41] Effect of Bend Geometry on Heat Transfer and Pressure Drop in a Two-Pass Coolant Square Channel for a Turbine
    Saha, Krishnendu
    Acharya, Sumanta
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2013, 135 (02):
  • [42] Rib spacing effect on heat transfer and pressure loss in a rotating two-pass rectangular channel (AR=1:2) with 45-degree angled ribs
    Liu, Yao-Hsien
    Wright, Lesley M.
    Fu, Wen-Lung
    Han, Je-Chin
    PROCEEDINGS OF THE ASME TURBO EXPO 2006, VOL 3, PTS A AND B: HEAT TRANSFER: GENERAL INTEREST, 2006, : 363 - 373
  • [43] Effects of bidirectional rib arrangements on turbulent flow structure and heat transfer characteristics of a two-pass channel for turbine blade internal cooling
    Majmader, Fawaz Bukht
    Hasan, Md Jahid
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 156
  • [44] Experimental study of heat-transfer and pressure-drop performances of a rotating two-pass channel with composite stepped skew ribs and internal effusion
    Chang, Shyy Woei
    Chen, Chi-An
    Lu, Yong-En
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 212
  • [45] Pressure and flow characteristics in a rotating two-pass square duct with 45-deg angled ribs
    Liou, TM
    Dai, GY
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2004, 126 (01): : 212 - 219
  • [46] Computational analysis of mist/air cooling in a two-pass rectangular rotating channel with 45-deg angled rib turbulators
    Dhanasekaran, T. S.
    Wang, Ting
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 61 : 554 - 564
  • [47] Comparison of V-shaped rib and curve-angled ribs by computation heat transfer enhancement and pressure drop internally two-phase flow in two-pass channel
    Oliwie, Amal
    AL-Turaihi, Riyadh
    MATERIALS TODAY-PROCEEDINGS, 2022, 61 : 1052 - 1060
  • [48] An extensive review on use of CFD simulation technique for assessment of performance of various rib geometries and arrangements in heated fluid ducts
    Deshpande, Harshad N.
    Raibhole, Vaijanath N.
    INTERNATIONAL JOURNAL OF ENGINEERING SYSTEMS MODELLING AND SIMULATION, 2024, 15 (06) : 269 - 283
  • [49] Flow structure, heat transfer and pressure drop in varying aspect ratio two-pass rectangular smooth channels
    Siddique, Waseem
    El-Gabry, Lamyaa
    Shevchuk, Igor V.
    Hushmandi, Narmin B.
    Fransson, Torsten H.
    HEAT AND MASS TRANSFER, 2012, 48 (05) : 735 - 748
  • [50] Flow structure, heat transfer and pressure drop in varying aspect ratio two-pass rectangular smooth channels
    Waseem Siddique
    Lamyaa El-Gabry
    Igor V. Shevchuk
    Narmin B. Hushmandi
    Torsten H. Fransson
    Heat and Mass Transfer, 2012, 48 : 735 - 748