Implementation of an in-house quantitative real-time polymerase chain reaction method for Hepatitis B virus quantification in West African countries

被引:14
|
作者
Ghosh, S. [1 ]
Sow, A. [2 ]
Guillot, C. [1 ]
Jeng, A. [3 ]
Ndow, G. [3 ,4 ]
Njie, R. [3 ,5 ]
Toure, S. [3 ]
Diop, M. [2 ]
Mboup, S. [2 ]
Kane, C. T. [2 ]
Lemoine, M. [4 ]
Thursz, M. [4 ]
Zoulim, F. [1 ,6 ]
Mendy, M. [5 ]
Chemin, I. [1 ]
机构
[1] Univ Claude Bernard, Ctr Rech Cancerol Lyon, INSERM U1052, CNRS UMR5286, Lyon, France
[2] Dantec, Dakar, Senegal
[3] MRC, Gambia Unit, Banjul, Gambia
[4] Imperial Coll London, Dept Hepatol, London, England
[5] IARC, Lab Serv & Biobank Grp DIR LSB, Lyon, France
[6] Hosp Civils Lyon, Dept Hepatol, Lyon, France
关键词
HBV; real-time quantification; Syber Green; viral load; viral quantification; PCR ASSAY; DNA;
D O I
10.1111/jvh.12561
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Hepatitis B virus (HBV) is a major cause of chronic liver disease worldwide. HBV infection is diagnosed by serological tests, while real-time polymerase chain reaction (qRT-PCR) assays are used to quantify viral load, which is a crucial parameter to determine viral replication and to monitor antiviral treatments. However, measuring viral load in resource-limited countries remains nonsystematic, due to the high cost of commercial kits. Here, we describe the development, validation and implementation of a low-cost, in-house qRT-PCR assay to monitor HBV viral load in chronic carriers enrolled in the PROLIFICA programme in the Gambia and Senegal. Over 1500 HBsAg-positive patients, including 210 chronically infected HBV patients, who were given antiviral treatment (tenofovir), were monitored by qRT-PCR using the SYBR Green- and HBV-specific primers. Twenty-four tenofovir-treated patients were followed up and their viral load was tested every 3months over the 12-month experimental time course. Compared to commercial assays, our in-house assay was shown to be (i) highly reliable, with good intra- and interassay reproducibility over a wide range (45-4.5x10(8) copies mL(-1)), (ii) very similar in the viral loads detected (R-2=.90), (iii) highly sensitive, as it detected loads as low as 30 copies mL(-1) (similar to 5 IU mL(-1)), (iv) cheaper (2- to 3-fold), (v) easier to implement and (vi) more rapid. Based on our experience, we recommend this assay as a reliable alternative to commercial assays, for monitoring HBV viraemia in resource-limited, highly endemic countries to reduce the cost and technical obstacles associated with commercial kits.
引用
收藏
页码:897 / 904
页数:8
相关论文
共 50 条
  • [31] Comprehensive algorithm for quantitative real-time polymerase chain reaction
    Zhao, S
    Fernald, RD
    JOURNAL OF COMPUTATIONAL BIOLOGY, 2005, 12 (08) : 1047 - 1064
  • [32] Real-time reverse transcriptase-polymerase chain reaction quantification of West Nile virus transmitted by Culex pipiens quinquefasciatus
    Vanlandingham, DL
    Schneider, BS
    Klingler, K
    Fair, J
    Beasley, D
    Huang, J
    Hamilton, P
    Higgs, S
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2004, 71 (01): : 120 - 123
  • [33] DEVELOPMENT, VALIDATION AND TESTING COSTS OF AN IN-HOUSE REAL-TIME POLYMERASE CHAIN REACTION ASSAY FOR THE DETECTION OF CHLAMYDIA TRACHOMATIS
    Dos Santos, Camila Gurgel
    Sabido, Meritxell
    Leturiondo, Andre Luiz
    Ferreira, Cynthia de Oliveira
    da Cruz, Thielle Pereira
    Benzaken, Adele Schwartz
    SEXUALLY TRANSMITTED INFECTIONS, 2017, 93 : A46 - A46
  • [34] Real-time polymerase chain reaction detection of parvovirus B19 DNA in blood donations using a commercial and an in-house assay
    Koppelman, M. H. G. M.
    van Swieten, P.
    Cuijpers, H. T. M.
    TRANSFUSION, 2011, 51 (06) : 1346 - 1354
  • [35] Detection and quantification of Gardnerella vaginalis by real-time polymerase chain reaction
    Naurath, EF
    Mohr, EL
    Adelson, ME
    Stemmer, SM
    Mordechai, E
    Trama, J
    OBSTETRICS AND GYNECOLOGY, 2005, 105 (04): : 66S - 66S
  • [36] Novel single-step multiplex real-time polymerase chain reaction assay for simultaneous quantification of hepatitis virus A, B, C, and E in serum
    Irshad, Mohammad
    Ansari, Mohammad Ahmad
    Irshad, Khushboo
    Lingaiah, Raghavendra
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 (12) : 1869 - 1876
  • [37] In-house abbreviated qualification of a real-time polymerase chain reaction method and strategies to amplify mycoplasma detection in human mesenchymal stromal cells
    Mathews, Smitha
    Rabani, Razieh
    Rasti, Mozhgan
    Viswanathan, Sowmya
    CYTOTHERAPY, 2021, 23 (11) : 1036 - 1044
  • [38] Application of Real-time Polymerase Chain Reaction for Quantitative Detection of Chicken Infectious Anemia Virus
    Chansiripornchai, Niwat
    Wanasawaeng, Wisanu
    Wongchidwan, Nantawan
    Chaichote, Supawadee
    Sasipreeyajan, Jiroj
    THAI JOURNAL OF VETERINARY MEDICINE, 2012, 42 (04): : 533 - 536
  • [39] Quantitative Real-Time Polymerase Chain Reaction Detection of BK Virus Using Labeled Primers
    Gu, Zhengming
    Pan, Jianmin
    Bankowski, Matthew J.
    Hayden, Randall T.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2010, 134 (03) : 444 - 448
  • [40] Quantification of Venturia inaequalis Growth in Malus x domestica with Quantitative Real-Time Polymerase Chain Reaction
    Gusberti, Michele
    Patocchi, Andrea
    Gessler, Cesare
    Broggini, Giovanni A. L.
    PLANT DISEASE, 2012, 96 (12) : 1791 - 1797