Implementation of an in-house quantitative real-time polymerase chain reaction method for Hepatitis B virus quantification in West African countries

被引:14
|
作者
Ghosh, S. [1 ]
Sow, A. [2 ]
Guillot, C. [1 ]
Jeng, A. [3 ]
Ndow, G. [3 ,4 ]
Njie, R. [3 ,5 ]
Toure, S. [3 ]
Diop, M. [2 ]
Mboup, S. [2 ]
Kane, C. T. [2 ]
Lemoine, M. [4 ]
Thursz, M. [4 ]
Zoulim, F. [1 ,6 ]
Mendy, M. [5 ]
Chemin, I. [1 ]
机构
[1] Univ Claude Bernard, Ctr Rech Cancerol Lyon, INSERM U1052, CNRS UMR5286, Lyon, France
[2] Dantec, Dakar, Senegal
[3] MRC, Gambia Unit, Banjul, Gambia
[4] Imperial Coll London, Dept Hepatol, London, England
[5] IARC, Lab Serv & Biobank Grp DIR LSB, Lyon, France
[6] Hosp Civils Lyon, Dept Hepatol, Lyon, France
关键词
HBV; real-time quantification; Syber Green; viral load; viral quantification; PCR ASSAY; DNA;
D O I
10.1111/jvh.12561
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Hepatitis B virus (HBV) is a major cause of chronic liver disease worldwide. HBV infection is diagnosed by serological tests, while real-time polymerase chain reaction (qRT-PCR) assays are used to quantify viral load, which is a crucial parameter to determine viral replication and to monitor antiviral treatments. However, measuring viral load in resource-limited countries remains nonsystematic, due to the high cost of commercial kits. Here, we describe the development, validation and implementation of a low-cost, in-house qRT-PCR assay to monitor HBV viral load in chronic carriers enrolled in the PROLIFICA programme in the Gambia and Senegal. Over 1500 HBsAg-positive patients, including 210 chronically infected HBV patients, who were given antiviral treatment (tenofovir), were monitored by qRT-PCR using the SYBR Green- and HBV-specific primers. Twenty-four tenofovir-treated patients were followed up and their viral load was tested every 3months over the 12-month experimental time course. Compared to commercial assays, our in-house assay was shown to be (i) highly reliable, with good intra- and interassay reproducibility over a wide range (45-4.5x10(8) copies mL(-1)), (ii) very similar in the viral loads detected (R-2=.90), (iii) highly sensitive, as it detected loads as low as 30 copies mL(-1) (similar to 5 IU mL(-1)), (iv) cheaper (2- to 3-fold), (v) easier to implement and (vi) more rapid. Based on our experience, we recommend this assay as a reliable alternative to commercial assays, for monitoring HBV viraemia in resource-limited, highly endemic countries to reduce the cost and technical obstacles associated with commercial kits.
引用
收藏
页码:897 / 904
页数:8
相关论文
共 50 条
  • [1] A rapid real-time quantitative polymerase chain reaction for hepatitis B virus
    Brechtbuehl, K
    Whalley, SA
    Dusheiko, GM
    Saunders, NA
    JOURNAL OF VIROLOGICAL METHODS, 2001, 93 (1-2) : 105 - 113
  • [2] A real-time quantitative polymerase chain reaction method for hepatitis B virus in patients with chronic hepatitis B treated with lamivudine
    Ide, T
    Kumashiro, R
    Koga, Y
    Tanaka, E
    Hino, T
    Hisamochi, A
    Murashima, S
    Ogata, K
    Tanaka, K
    Kuwahara, R
    Sata, M
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (09): : 2048 - 2051
  • [3] Rapid quantification of semen hepatitis B virus DNA by real-time polymerase chain reaction
    Marie C. Lin
    Hsiang-Fu Kung
    Li-Ka Shing
    World Journal of Gastroenterology, 2005, (34) : 5385 - 5389
  • [4] Rapid quantification of semen hepatitis B virus DNA by real-time polymerase chain reaction
    Qian, Wei-Ping
    Tan, Yue-Qiu
    Chen, Ying
    Peng, Ying
    Li, Zhi
    Lu, Guang-Xiu
    Lin, Marie C.
    Kung, Hsiang-Fu
    He, Ming-Ling
    Shing, Li-Ka
    WORLD JOURNAL OF GASTROENTEROLOGY, 2005, 11 (34) : 5385 - 5389
  • [5] In-house quantitative real-time PCR for the diagnosis of hepatitis B virus and hepatitis C virus infections
    Gomes Zauli, Danielle Alves
    Paula de Menezes, Carla Lisandre
    de Oliveira, Cristiane Lommez
    Cueva Mateo, Elvis Cristian
    de Souza Ferreira, Alessandro Clayton
    BRAZILIAN JOURNAL OF MICROBIOLOGY, 2016, 47 (04) : 987 - 992
  • [6] Detection and quantification of hepatitis B virus DNA by SYBR green real-time polymerase chain reaction
    Olioso, D.
    Boaretti, M.
    Ligozzi, M.
    Lo Cascio, G.
    Fontana, R.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2007, 26 (01) : 43 - 50
  • [7] Detection and quantification of hepatitis B virus DNA by SYBR green real-time polymerase chain reaction
    D. Olioso
    M. Boaretti
    M. Ligozzi
    G. Lo Cascio
    R. Fontana
    European Journal of Clinical Microbiology & Infectious Diseases, 2007, 26 : 43 - 50
  • [8] Real-Time Polymerase Chain Reaction-Based Detection and Quantification of Hepatitis B Virus DNA
    Bag, Satyabrata
    Ghosh, Santanu
    Lalwani, Roopa
    Vishnoi, Pratishtha
    Gupta, Sudheer
    Dubey, Dhirendra
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (202):
  • [9] Quantitation of hepatitis C virus using an in-house real-time reverse transcriptase polymerase chain reaction in plasma samples
    Daniel, Hubert Darius J.
    Chandy, George M.
    Abraham, Priya
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2008, 61 (04) : 415 - 420
  • [10] Evaluation of an in-house real-time polymerase chain reaction method to identify group B streptococcus colonization in pregnancy
    Yeung, Sik-Wing
    Cheung, Pik-Tsz
    Chau, Sze-Lok
    Ip, Margaret
    Lao, Terence Tzu-Hsi
    Leung, Tak-Yeung
    Tam, Wing-Hung
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2015, 41 (09) : 1357 - 1362